History of blood gas analysis. VII. Pulse oximetry

1987 ◽  
Vol 3 (2) ◽  
pp. 135-138 ◽  
Author(s):  
John W. Severinghaus ◽  
Yoshiyuki Honda
2018 ◽  
Vol 29 (1) ◽  
pp. 169-172
Author(s):  
Gian Luca Salvagno ◽  
Davide Demonte ◽  
Giuseppe Lippi

A 51-year old male patient was admitted to the hospital with acute dyspnea and history of chronic asthma. Venous blood was drawn into a 3.0 mL heparinized syringe and delivered to the laboratory for blood gas analysis (GEM Premier 4000, Instrumentation Laboratory), which revealed high potassium value (5.2 mmol/L; reference range on whole blood, 3.5-4.5 mmol/L). This result was unexpected, so that a second venous blood sample was immediately drawn by direct venipuncture into a 3.5 mL lithium-heparin blood tube, and delivered to the laboratory for repeating potassium testing on Cobas 8000 (Roche Diagnostics). The analysis revealed normal plasma potassium (4.6 mmol/L; reference range in plasma, 3.5-5.0 mmol/L) and haemolysis index (5; 0.05 g/L). Due to suspicion of spurious haemolysis, heparinized blood was transferred from syringe into a plastic tube and centrifuged. Potassium and haemolysis index were then measured in this heparinized plasma, confirming high haemolysis index (50; 0.5 g/L) and pseudohyperkalemia (5.5 mmol/L). Investigation of this case revealed that spurious haemolysis was attributable to syringe delivery in direct ice contact for ~15 min. This case emphasizes the importance of avoiding sample transportation in ice and the need of developing point of care analysers equipped with interference indices assessment.


1985 ◽  
Vol 1 (3) ◽  
pp. 180-192 ◽  
Author(s):  
John W. Severinghaus ◽  
Paul B. Astrup

Breathe ◽  
2015 ◽  
Vol 11 (3) ◽  
pp. 194-201 ◽  
Author(s):  
Julie-Ann Collins ◽  
Aram Rudenski ◽  
John Gibson ◽  
Luke Howard ◽  
Ronan O’Driscoll

Key PointsIn clinical practice, the level of arterial oxygenation can be measured either directly by blood gas sampling to measure partial pressure (PaO2) and percentage saturation (SaO2) or indirectly by pulse oximetry (SpO2).This review addresses the strengths and weaknesses of each of these tests and gives advice on their clinical use.The haemoglobin–oxygen dissociation curve describing the relationship between oxygen partial pressure and saturation can be modelled mathematically and routinely obtained clinical data support the accuracy of a historical equation used to describe this relationship.Educational AimsTo understand how oxygen is delivered to the tissues.To understand the relationships between oxygen saturation, partial pressure, content and tissue delivery.The clinical relevance of the haemoglobin–oxygen dissociation curve will be reviewed and we will show how a mathematical model of the curve, derived in the 1960s from limited laboratory data, accurately describes the relationship between oxygen saturation and partial pressure in a large number of routinely obtained clinical samples.To understand the role of pulse oximetry in clinical practice.To understand the differences between arterial, capillary and venous blood gas samples and the role of their measurement in clinical practice.The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content), saturation (SO2) and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin–oxygen dissociation curve, a graphical representation of the relationship between oxygen satur­ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the SO2 in blood from patients with normal pH and SO2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (SpO2) is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (SaO2) as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable SpO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.


1988 ◽  
Vol 68 (6) ◽  
pp. 977-977 ◽  
Author(s):  
THOMAS F. HORNBEIN

1996 ◽  
Vol 17 (2) ◽  
pp. 53-63
Author(s):  
Karen Z. Voter ◽  
John T. McBride

Objective measurements of a wide variety of aspects of respiratory function can be useful in the evaluation and management of children and adolescents who have respiratory symptoms or disorders. Many of the tests described in this article can be performed reasonably in the pediatrician's office. Pediatricians can be comfortable in measuring and interpreting pulse oximetry, blood gas analysis, spirometry, and peak flow. They also should be familiar with the indications for the less common tests of pulmonary function that now are widely available.


2021 ◽  
pp. 1-3
Author(s):  
Sritam Mohanty ◽  
Rangaraj Setlur ◽  
Jyoti Kumar Sinha

Introduction: Arterial blood gas (ABG) analysis is the gold standard method and frequently performed intervention to evaluate acid-base status along with adequacy of ventilation and oxygenation among patients with predominantly critical / acute diseases. Aims And Objectives: The aim of this study is to evaluate the correlation of VBG analysis and pulse oximetry (SpO2) with ABG analysis in critically ill patients. Materials And Methods:Intensive Care Unit (ICU), Command Hospital (Eastern Command), Kolkata, Adult patients requiring arterial blood gas analysis, JAN 2018 –JUNE 2019, 100 critically ill patients and Age – 18yrs and older, Sex – Either sex. Conclusion: In this study population of critically ill patients, pH and pCO2 on VBG analysis correlated with pH and pCO2 on ABG analysis. The SpO2 correlated well with pO2 on ABG analysis


2016 ◽  
Vol 43 (6) ◽  
pp. 211
Author(s):  
Srie Yanda ◽  
Munar Lubis ◽  
Yoyoh Yusroh

Background Arterial blood gas is usually beneficial to discern thenature of gas exchange disturbances, the effectiveness of com-pensation, and is required for adequate management. AlthoughPaO 2 is the standard measurement of blood oxygenation, oxygensaturation measured by pulse oximetry (SapO 2 ) is now a custom-ary noninvasive assessment of blood oxygenation in newborn in-fants.Objective To compare oxygen saturation measured by pulse oxi-metry (SapO 2 ) and arterial blood gas (SaO 2 ), its correlation withother variables, and to predict arterial partial pressure of oxygen(PaO 2 ) based on SapO 2 values.Methods A cross sectional study was conducted on all neonatesadmitted to Pediatric Intensive Care Unit (PICU) during February2001 to May 2002. Neonates were excluded if they had impairedperipheral perfusion and/or congenital heart defects. Paired t-testwas used to compare SapO 2 with SaO 2 . Correlation between twoquantitative data was performed using Pearson’s correlation. Re-gression analysis was used to predict PaO 2 based on SapO 2 val-ues.Results Thirty neonates were included in this study. The differ-ence between SaO 2 and SapO 2 was significant . There were sig-nificant positive correlations between heart rate /pulse rate andTCO 2 , HCO 3 ; respiratory rate and TCO 2 , HCO 3 , base excess (BE);core temperature and HCO 3 , BE; surface temperature and pH,TCO 2, HCO 3, BE; SapO 2 and pH, PaO 2 ; and significant negativecorrelation between SapO 2 and PaCO 2 ; the correlations were weak.The linear regression equation to predict PaO 2 based on SapO 2values was PaO 2 = -79.828 + 1.912 SapO 2 .Conclusion Pulse oximetry could not be used in place of arterialblood gas analysis available for clinical purpose


Sign in / Sign up

Export Citation Format

Share Document