Immiscible two-component two-phase gas?liquid heat transfer on shell side of a TEMA-F heat exchanger

2004 ◽  
Vol 40 (3-4) ◽  
pp. 301-306 ◽  
Author(s):  
Li Wang ◽  
Xing-Hua Huang ◽  
Zhen Lu
2018 ◽  
Vol 70 ◽  
pp. 02003
Author(s):  
Janusz T. Cieśliński ◽  
Maciej Fabrykiewicz

This paper presents thermal characteristics of prototype of a two-phase thermosyphon heat exchanger (TPTHEx) charged with acetone as a working fluid. The TPTHEx consists of two horizontal cylindrical vessels connected by two risers and a downcomer. Tube bundles placed in the lower and upper cylinders work as an evaporator and a condenser, respectively. The tested TPTHEx operates in a vacuum. Therefore, the working liquid is boiled in temperatures ranging from 33°C to 62°C. The overall heat transfer coefficient (OHTC) of the tested TPTHEx was estimated by the use of the Wilson method and the modified Peclet equation. The results obtained indicate a superiority of water over acetone as a working fluid. Moreover, it was shown that having a lower pressure in the shell-side of TPTHEx results in a higher overall heat transfer coefficient. The Wilson method and the modified Peclet equation predict OHTC with satisfactory agreement.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Swanand Gaikwad ◽  
Ashish Parmar

AbstractHeat exchangers possess a significant role in energy transmission and energy generation in most industries. In this work, a three-dimensional simulation has been carried out of a shell and tube heat exchanger (STHX) consisting of segmental baffles. The investigation involves using the commercial code of ANSYS CFX, which incorporates the modeling, meshing, and usage of the Finite Element Method to yield numerical results. Much work is available in the literature regarding the effect of baffle cut and baffle spacing as two different entities, but some uncertainty pertains when we discuss the combination of these two parameters. This study aims to find an appropriate mix of baffle cut and baffle spacing for the efficient functioning of a shell and tube heat exchanger. Two parameters are tested: the baffle cuts at 30, 35, 40% of the shell-inside diameter, and the baffle spacing’s to fit 6,8,10 baffles within the heat exchanger. The numerical results showed the role of the studied parameters on the shell side heat transfer coefficient and the pressure drop in the shell and tube heat exchanger. The investigation shows an increase in the shell side heat transfer coefficient of 13.13% when going from 6 to 8 baffle configuration and a 23.10% acclivity for the change of six baffles to 10, for a specific baffle cut. Evidence also shows a rise in the pressure drop with an increase in the baffle spacing from the ranges of 44–46.79%, which can be controlled by managing the baffle cut provided.


2013 ◽  
Vol 378 ◽  
pp. 459-465
Author(s):  
Ya Guo Lu ◽  
Peng Fei Zhu

A calculate method based on ε-NTU model for heat transfer characteristics of shell-tube fuel-cooled heat exchanger of aero-engine lubrication system was built. The heat convection coefficient was obtained by a dimensionless curve (Re~StPr2/3), which was detailed introduced as well. A case study was executed at last. The absolute error of the outlet lubrication of the tube side and the shell side between the value of calculation and experiment was less than ±10°C, and the relative error was less than 6.5%. The absolute error of the heat transferred between calculation and experiment was less than ±0.9kW, and the relative error was less than 7.4%. It indicates that the mothod is available for the investigation of heat transfer characteristics of shell-tube fuel-cooled heat exchanger.