Comparison of radiation dose and image quality between contrast-enhanced single- and dual-energy abdominopelvic computed tomography in children as a function of patient size

Author(s):  
Marilyn J. Siegel ◽  
Joyce C. Mhlanga ◽  
Amber Salter ◽  
Juan Carlos Ramirez-Giraldo
2018 ◽  
Vol 51 (6) ◽  
pp. 377-384 ◽  
Author(s):  
Rodrigo Canellas ◽  
Subba Digumarthy ◽  
Azadeh Tabari ◽  
Alexi Otrakji ◽  
Shaunagh McDermott ◽  
...  

Abstract Objective: To determine whether dual-energy computed tomography (DECT) of the chest can be performed at a reduced radiation dose, with an emphasis on images generated with post-processing techniques. Materials and Methods: In 21 patients undergoing DECT of the chest in a dual-source scanner, an additional image series was acquired at a reduced radiation dose. Four thoracic radiologists assessed both image series for image quality, normal thoracic structures, as well as pulmonary and mediastinal abnormalities, on virtual monochromatic images at 40 keV and 60 keV. Data were analyzed with Student's t-test, kappa statistics, analysis of variance, and the Wilcoxon signed-rank test. Results: The overall image quality of 60 keV virtual monochromatic images at a reduced radiation dose was considered optimal in all patients, and no abnormalities were missed. Contrast enhancement and lesion detection performance were comparable between reduced-dose images at 40 keV and standard-of-care images at 60 keV. The intraobserver and interobserver agreement were both good. The mean volumetric CT dose index (CTDIvol), size-specific dose estimate (SSDE), dose-length product (DLP), and effective dose (ED) for reduced-dose DECT were 3.0 ± 0.6 mGy, 4.0 ± 0.6 mGy, 107 ± 30 mGy.cm, and 1.5 ± 0.4 mSv, respectively. Conclusion: DECT of the chest can be performed at a reduced radiation dose (CTDIvol < 3 mGy) without loss of diagnostic information.


PLoS ONE ◽  
2021 ◽  
Vol 16 (1) ◽  
pp. e0244079
Author(s):  
Shingo Ohira ◽  
Naoyuki Kanayama ◽  
Kentaro Wada ◽  
Toshiki Ikawa ◽  
Takero Hirata ◽  
...  

To assess the objective and subjective image quality, and respiratory motion of hepatocellular carcinoma with portal vein tumor thrombosis (PVTT) using the contrast-enhanced four-dimensional dual-energy computed tomography (CE-4D-DECT). For twelve patients, the virtual monochromatic image (VMI) derived from the CE-4D-DECT with the highest contrast to noise ratio (CNR) was determined as the optimal VMI (O-VMI). To assess the objective and subjective image quality, the CNR and five-point score of the O-VMI were compared to those of the standard VMI at 77 keV (S-VMI). The respiratory motion of the PVTT and diaphragm was measured based on the exhale and inhale phase images. The VMI at 60 keV yielded the highest CNR (4.8 ± 1.4) which was significantly higher (p = 0.02) than that in the S-VMI (3.8 ± 1.2). The overall image quality (4.0 ± 0.6 vs 3.1 ± 0.5) and tumor conspicuity (3.8 ± 0.8 vs 2.8 ± 0.6) of the O-VMI determined by three radiation oncologists was significantly higher (p < 0.01) than that of the S-VMI. The diaphragm motion in the L-R (3.3 ± 2.5 vs 1.2 ± 1.1 mm), A-P (6.7 ± 4.0 vs 1.6 ± 1.3mm) and 3D (8.8 ± 3.5 vs 13.1 ± 4.9 mm) directions were significantly larger (p < 0.05) compared to the tumor motion. The improvement of objective and subjective image quality was achieved in the O-VMI. Because the respiratory motion of the diaphragm was larger than that of the PVTT, we need to be pay attention for localizing target in radiotherapy.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
P Poskaite ◽  
M Pamminger ◽  
C Kranewitter ◽  
C Kremser ◽  
M Reindl ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background The natural history of thoracic aortic aneurysm (TAA) is one of progressive expansion. Asymptomatic patients who do not meet criteria for repair require conservative management including ongoing aneurysm surveillance, mostly carried out by contrast-enhanced computed tomography angiography (CTA). Purpose To prospectively compare image quality and reliability of a prototype non-contrast, self-navigated 3D whole-heart magnetic resonance angiography (MRA) with contrast-enhanced computed tomography angiography (CTA) for sizing of thoracic aortic aneurysm (TAA). Methods Self-navigated 3D whole-heart 1.5 T MRA was performed in 20 patients (aged 67 ± 8.6 years, 75% male) for sizing of TAA; a subgroup of 18 (90%) patients underwent additional contrast-enhanced CTA on the same day. Subjective image quality was scored according to a 4-point Likert scale and ratings between observers were compared by Cohen’s Kappa statistics. Continuous MRA and CTA measurements were analyzed with regression and Bland-Altman analysis. Results Overall subjective image quality as rated by two observers was 1 [interquartile range (IQR) 1-2] for self-navigated MRA and 1.5 [IQR 1-2] for CTA (p = 0.717). For MRA a perfect inter-observer agreement was found for presence of artefacts and subjective image sharpness (κ=1). Subjective signal inhomogeneity correlated highly with objectively quantified inhomogeneity of the blood pool signal (r = 0.78-0.824, all p &lt;0.0001). Maximum diameters of TAA as measured by self-navigated MRA and CTA showed excellent correlation (r = 0.997, p &lt; 0.0001) without significant inter-method bias (bias -0.0278, lower and upper limit of agreement -0.74 and 0.68, p = 0.749). Inter- and intraobserver correlation of aortic aneurysm as measured by MRA was excellent (r = 0.963 and 0.967, respectively) without significant bias (all p ≤ 0.05). Conclusion Self-navigated 3D whole-heart MRA enables reliable contrast- and radiation free aortic dilation surveillance without significant difference to standardized CTA while providing predictable acquisition time and by offering excellent image quality. Abstract Figure.


Diagnostics ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. 870
Author(s):  
Saif Afat ◽  
Ahmed E. Othman ◽  
Konstantin Nikolaou ◽  
Sebastian Gassenmaier

To evaluate contrast-enhanced dual-energy computed tomography (DECT) chest examinations regarding pulmonary perfusion patterns and pulmonary opacities in patients with confirmed COVID-19 disease. Fourteen patients with 24 DECT examinations performed between April and May 2020 were included in this retrospective study. DECT studies were assessed independently by two radiologists regarding pulmonary perfusion defects, using a Likert scale ranging from 1 to 4. Furthermore, in all imaging studies the extent of pulmonary opacities was quantified using the same rating system as for perfusion defects. The main pulmonary findings were ground glass opacities (GGO) in all 24 examinations and pulmonary consolidations in 22 examinations. The total lung scores after the addition of the scores of the single lobes showed significantly higher values of opacities compared to perfusion defects, with a median of 12 (9–18) for perfusion defects and a median of 17 (15–19) for pulmonary opacities (p = 0.002). Furthermore, mosaic perfusion patterns were found in 19 examinations in areas with and without GGO. Further studies will be necessary to investigate the pathophysiological background of GGO with maintained perfusion compared to GGO with reduced perfusion, especially regarding long-term lung damage and prognosis.


Sign in / Sign up

Export Citation Format

Share Document