scholarly journals The initial experience of the upper abdominal CT angiography using low-concentration contrast medium on dual energy spectral CT

2015 ◽  
Vol 40 (7) ◽  
pp. 2894-2899 ◽  
Author(s):  
Lei Xin ◽  
Xiaotang Yang ◽  
Ning Huang ◽  
Xiaosong Du ◽  
Jianxin Zhang ◽  
...  
2016 ◽  
Vol 70 (9B) ◽  
pp. B37-B43 ◽  
Author(s):  
Yijun Liu ◽  
Ailian Liu ◽  
Lei Liu ◽  
Shifeng Tian ◽  
Jinghong Liu ◽  
...  

2014 ◽  
Vol 22 (5) ◽  
pp. 689-696 ◽  
Author(s):  
Jie Liu ◽  
Pei-Jie Lv ◽  
Runze Wu ◽  
Yong-Gao Zhang ◽  
Li-Li Hu ◽  
...  

2021 ◽  
pp. 20200974
Author(s):  
Xirong Zhang ◽  
Jing Chen ◽  
Nan Yu ◽  
Zhanli Ren ◽  
Qian Tian ◽  
...  

Objective: To evaluate the value of using low energy (keV) images in renal dual-energy spectral CT angiography (CTA) and adaptive statistical iterative reconstruction (ASIR) to reduce contrast medium dose. Methods: 40 patients with renal CTA on a Discovery CT750HD were randomly divided into two groups: 20 cases (Group A) with 600 mgI kg−1 and 20 cases (Group B) with 300 mgI kg−1. The scan protocol for both groups was: dual-energy mode with mA selection for noise index of 10 HU, pitch 1.375:1, rotating speed 0.6 s/r. Images were reconstructed at 0.625 mm thickness with 40%ASIR, Group A used the conventional 70keV monochromatic images, and Group B used monochromatic images from 40 to 70 keV at 5 keV interval for analysis. The CT values and standard deviation (SD) values of the renal artery and erector spine in the plain and arterial phases were measured with the erector spine SD value representing image noise. The enhancement degree of the renal artery (ΔCT = CT(arterial) -CT(plain)), signal-to-noise ratio (SNR=CTrenal-artery/SDrenal-artery) and contrast-to-noise ratio (CNR=(CTrenal-artery-CTerector spine)/SDerector-spine) were calculated. The single factor analysis of variance was used to analyze the difference of ΔCT, SNR and CNR among image groups with p < 0.05 being statistically significant. The subjective image scores of the groups were assessed blindly by two experienced physicians using a 5-point system and the score consistency was compared by the κ test. Results: Contrast medium dose in the 300 mgI kg−1 group was reduced by 50% compared with the 600 mgI kg−1 group, while radiation dose was similar between the two groups. The subjective scores were 4.00 ± 0.65, 4.50 ± 0.60 and 3.70 ± 0.80 for images at 70 keV (600 mgI kg−1 group), 40 keV (300 mgI kg−1 group) and 45 keV (300 mgI kg−1 group), respectively with good consistency between the two reviewers (p > 0.05). The 40 keV images in the 300 mgI kg−1 group had similar ΔCT (469.77 ± 86.95 HU vs 398.54 ± 73.68 HU) and CNR (15.52 ± 3.32 vs 18.78 ± 6.71) values as the 70 keV images in the 600 mgI kg−1) group but higher SNR values (30.19 ± 4.41 vs 16.91 ± 11.12, p < 0,05) Conclusion: Contrast dose may be reduced by 50% while maintaining image quality by using lower energy images combined with ASIR in renal dual-energy CTA. Advances in knowledge: Combined with ASIR and energy spectrum, can reduce the amount of contrast dose in renal CTA.


2018 ◽  
pp. 20170631 ◽  
Author(s):  
Guangming Ma ◽  
Yong YU ◽  
Haifeng Duan ◽  
Yuequn Dou ◽  
Yongjun Jia ◽  
...  

PLoS ONE ◽  
2015 ◽  
Vol 10 (9) ◽  
pp. e0139275 ◽  
Author(s):  
Abdulrahman Almutairi ◽  
Zhonghua Sun ◽  
Abduljaleel Poovathumkadavi ◽  
Tarek Assar

PLoS ONE ◽  
2015 ◽  
Vol 10 (12) ◽  
pp. e0145976 ◽  
Author(s):  
Abdulrahman Almutairi ◽  
Zhonghua Sun ◽  
Abduljaleel Poovathumkadavi ◽  
Tarek Assar

2002 ◽  
Vol 37 (S13) ◽  
pp. 106-111 ◽  
Author(s):  
Masashi Kimura ◽  
Yasukazu Shioyama ◽  
Toshiyuki Okumura ◽  
Kouji Yamada ◽  
Michihisa Kawashima ◽  
...  

2017 ◽  
Vol 25 (1) ◽  
pp. 135-143 ◽  
Author(s):  
Yongxia Zhao ◽  
Yanmin Wu ◽  
Ziwei Zuo ◽  
Hongna Suo ◽  
Sisi Zhao ◽  
...  

PLoS ONE ◽  
2013 ◽  
Vol 8 (11) ◽  
pp. e80939 ◽  
Author(s):  
Yu Chen ◽  
Huadan Xue ◽  
Zheng-yu Jin ◽  
Jie Zhang ◽  
Hao Sun ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document