scholarly journals Endovascular treatment of infrapopliteal arteries: angioplasty vs stent in the drug-eluting era

2014 ◽  
Vol 24 (4) ◽  
pp. 793-798 ◽  
Author(s):  
Fabrizio Fanelli ◽  
Alessandro Cannavale
Stroke ◽  
2021 ◽  
Vol 52 (Suppl_1) ◽  
Author(s):  
Mahmoud Mohammaden ◽  
Raul G Nogueira ◽  
WONDWOSSEN TEKLE ◽  
farhan siddiq ◽  
Diogo C Haussen ◽  
...  

Introduction: Intracranial atherosclerotic disease (ICAD) is a common cause of refractory stroke. Randomized clinical trials failed to prove the safety and efficacy of the endovascular treatment options of symptomatic ICAD (sICAD). However, there are many concerns regarding inclusion criteria in these trials which made them less effective than standard medical management. Herein, we aim to study the safety and efficacy of drug-eluting balloon mounted stents (DES) in the treatment of sICAD. Methods: A retrospective review of endovascular database from 10 comprehensive stroke centers inside and outside the USA from January 2017 to January 2020 was reviewed. Patients were included if they had symptomatic intracranial stenosis ≥70% in the target vessel, failed best medical management, and underwent intracranial stenting with DES. The primary outcome was the occurrence of ischemic stroke, hemorrhage, or mortality within 72 hours of the procedure. Secondary outcomes included rates of symptomatic and angiographic recurrence within 6 months of the procedure. Results: There was a total of 129 patients, the median age was 65 [58-72] years, 40 (31%) were females. The intracranial stenotic lesions were located in anterior circulation in 74 (57.4%) of cases [24 (18.6%) supraclinoid ICA, 5 (3.9%) cavernous ICA, 17 (13.2%) petrous ICA, 5 (19.4%) MCA-M1, and 3 (2.3%) M2] and in posterior circulation in 55 (42.6%) of cases [36 (27.9) vertebral artery V4 segment, 18 (14%) basilar and 1 (0.7%) PCA]. Recurrent stroke was the qualifying event in 101 (78.3%) while transient ischemic attacks (TIA) were identified in 28 (21.7%) of cases. The median time from the qualifying event to stenting was 6 [2-24] days. Strokes were reported within 72 hours of the procedure; 2 (1.6%) ischemic, 2 (1.6%) hemorrhagic strokes and 2 (1.6%) patients suffered inpatient mortality. The median follow-up time was 6 [3-6.75] months. Among 99 patients who had clinical follow up 2 (2%) had TIA and 6 (6.1%) had strokes. Fifty-one patients had follow-up imaging of whom symptomatic ISR was reported in 8 (15.7%). Conclusion: Our study has shown that in appropriately selected patients with sICAD, endovascular treatment using DES is safe and effective. Prospective randomized clinical trials are warranted.


2018 ◽  
Vol 20 (3) ◽  
pp. 260-269 ◽  
Author(s):  
Jan “John” Swinnen ◽  
Kerry Hitos ◽  
Lukas Kairaitis ◽  
Simon Gruenewald ◽  
George Larcos ◽  
...  

Background: Endovascular treatment of autogenous arteriovenous haemodialysis fistula stenosis has high reintervention rates. We investigate the effect of drug-eluting balloons in the treatment of recurrent haemodialysis fistula stenosis. Methods: This is a randomised, controlled, investigator-initiated and run, prospective, blinded, multicentre trial. Patients with recurrent autogenous arteriovenous haemodialysis fistula stenosis received standard endovascular treatment plus drug-eluting balloon or standard endovascular treatment plus uncoated balloon (Sham). Primary endpoint was late lumen loss in trial area on ultrasound at 6 weeks, 3, 6 and 12 months. Secondary endpoints were freedom from reintervention to the Index Trial Area and decline in fistula flow (Qa). Interim analysis was performed at 6 months (unblinded due to timeliness). Results: Patients with 132 recurrent stenoses (48% in bare Nitinol stents) were randomised with 70 receiving drug-eluting balloon and 62 Sham. At 6 months, decline in late lumen loss was 0.23 ± 0.03 mm/month for Sham and 0.045 ± 0.03 mm/month for drug-eluting balloon arm, a significant difference (0.18 mm, p = 0.0002). At 12 months, this difference persisted at 0.12 mm (p = 0.0003). At 6 months, significant difference in late lumen loss for instent restenoses (p = 0.0004) was observed, with non-significant difference for unstented restenoses (p = 0.065). Mean time for freedom from reintervention was 10.14 months for Sham versus 42.39 months for drug-eluting balloon (p = 0.001). The same was shown for instent (p = 0.014) and unstented (p = 0.029) restenoses. Qa decline rate at 6 months was 36.89 mL/min/month (Sham) and 0.41 mL/min (drug-eluting balloon). The difference was significant (36.48 mL/min; p = 0.02) and persisted to 12 months (p = 0.44). Conclusion: Paclitaxel drug-eluting balloon significantly delays restenosis after angioplasty for recurrent autogenous arteriovenous haemodialysis fistula stenosis, persisting to 12 months. Drug-eluting balloon significantly increases freedom from reintervention at 12 months with these effects true in stented and unstented fistulas.


2013 ◽  
Vol 34 (suppl 1) ◽  
pp. P361-P361
Author(s):  
S. Cassese ◽  
G. Ndrepepa ◽  
G. Tepe ◽  
I. Ott ◽  
L. King ◽  
...  

2013 ◽  
Vol 62 (18) ◽  
pp. B254
Author(s):  
Salvatore Cassese ◽  
Gjin Ndrepepa ◽  
Gunnar Tepe ◽  
Lamin King ◽  
Ilka Ott ◽  
...  

2011 ◽  
Vol 58 (11) ◽  
pp. 1105-1109 ◽  
Author(s):  
Andrej Schmidt ◽  
Michael Piorkowski ◽  
Martin Werner ◽  
Matthias Ulrich ◽  
Yvonne Bausback ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document