scholarly journals Modified ablation index: a novel determinant of a successful first-pass left atrial posterior wall isolation

2021 ◽  
Author(s):  
Satoshi Hayashida ◽  
Koichi Nagashima ◽  
Sayaka Kurokawa ◽  
Masaru Arai ◽  
Ryuta Watanabe ◽  
...  
2020 ◽  
Author(s):  
Satoshi Hayashida ◽  
Koichi Nagashima ◽  
Sayaka Kurokawa ◽  
Masaru Arai ◽  
Ryuta Watanabe ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
Y Matsunaga ◽  
Y Egami ◽  
M Yano ◽  
M Yamato ◽  
R Shutta ◽  
...  

Abstract Background It has been reported that elimination of non-pulmonary vein (PV) triggers after PV isolation is a good predictor of atrial tachyarrhythmia free survival. However, precise mapping of triggers outside from superior vena cava (SVC) or left atrial posterior wall (LAPW) are difficult. The aim of this study is to assess the efficacy of self-reference mapping technique to eliminate non-PV triggers originated from outside of primordial pulmonary vein area. Methods Total of 431 patients (446 procedures) underwent atrial fibrillation (AF) ablation in a hospital and in a medical center from January 2017 to March 2019. After isolation of PV, non-PV triggers were induced with isoproterenol and/or adenosine triphosphate. Reproducible non-PV triggers were targeted to ablate using following self-reference mapping technique: A trigger conducts centrifugally and the earliest site should be distinguished from other later activated sites. Using a PentaRay multipolar catheter, the operators annotated the earliest site of local activation and a reference tag was placed. The multipolar catheter was then moved to the reference tag and the process repeated. Ultimately, we identified clusters of early circumferential activation and ablated. Results A total of 32 non-PV triggers excluding the origin from LAPW and SVC were induced in 23 patients. Nineteen triggers (59%) were located in the right atrium and 13 triggers (41%) in the left atrium (Figure 1). All triggers were eliminated with ablation and AF was non-inducible in all patients at the end of the procedure. During the follow-up (529±270 days), 18 patients (77%) were free from atrial tachyarrhythmias after a 3-month blanking period. Three patients received additional ablation procedures for recurrent atrial arrhythmias. No non-PV triggers ablated during the previous procedure were observed. Conclusion A novel self-reference mapping technique is useful for eliminating non-PV triggers in terms of the short- and long-term success. Figure 1. Distribution of non-PV triggers Funding Acknowledgement Type of funding source: None


2014 ◽  
Vol 41 (1) ◽  
pp. 87-90 ◽  
Author(s):  
Sergey Y. Boldyrev ◽  
Murat K. Lepshokov ◽  
Igor I. Yakuba ◽  
Kirill O. Barbukhatty ◽  
Vladimir A. Porhanov

We present a novel technique for resolving the problem of radical size mismatch at the time of orthotopic transplantation. A 48-year-old man presented with chronic rheumatic heart disease and a giant left atrium. Twenty-three years before, he had undergone mitral valve replacement with a mechanical prosthesis. At the time of the repeated intervention, the volume of his left atrium was 350 mL. Surgical features of the transplantation included approximation of the pulmonary vein ostia by gathering sutures intentionally, in order to decrease the area of the left atrial posterior wall and thereby enable appropriate coaptation with the donor left atrium. After the operation, left atrial volume had been reduced to 60 mL.


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
C Teres ◽  
B Jauregui ◽  
D Soto-Iglesias ◽  
A Ordonez ◽  
A Chauca ◽  
...  

Abstract Funding Acknowledgements Dr Teres was funded by Swiss Heartrhythm Foundation Introduction Circumferential pulmonary vein isolation (PVI) has become a mainstay in the treatment of atrial fibrillation (AF). The utility of ablation index (AI) to dose radiofrequency delivery for the reduction of AF recurrences has already been proven with a target AI ≥ 400 at the posterior wall and ≥550 at the anterior Wall. Nevertheless, the left atrial wall is a thin, heterogeneous structure with an important inter and intra-patient variability of LAWT. Objective To determine if adapting AI to atrial wall thickness (AWT) is feasible, effective and safe during AF ablation. Methods Single-Center study that included 80 consecutive patients referred for a first paroxysmal AF ablation that was performed with a single catheter approach with the intention to reduce vascular access complication rate. All patients had a MDCT prior to the ablation procedure. LAWT maps were semi-automatically computed from the MDCT as the local distance between the LA endo and epicardium. All procedures were performed under general anesthesia with a high-rate low-volume ventilation protocol for obtaining higher catheter stability. The transeptal puncture was TEE-guided. During the procedure, the WT map was fused with the LA anatomy using CARTO-merge. LAWT was categorized into 1mm-layers and the AI was titrated to the local atrial WT as follows: Thickness < 1 mm (red): 300; 1-2 mm (yellow): 350; 2-3 mm (green): 400; 3-4 mm (blue): 450; > 4 mm (purple): 450 (Figure). Maximal inter-lesion distance was set at 6 mm. VisiTag settings were: catheter position stability: minimum time 3 s, maximum range 4 mm; force over time: 25%, minimum force 3 g; lesion tag size: 3 mm. Respiration training was not possible due to the high catheter stability.  The circumferential ablation line was designed in a personalized fashion to avoid thicker regions. Results 80 patients [41 (51,2 %) male, age 60± 11 years] were included. Mean LVEF was 59 ± 5 %, Mean LA diameter 39,1 ± 5,8 mm, Mean LAWT was 1.36 ± 0.63 mm. Mean AI was 352 ± 36 on the RPVs and 356 ± 36 on the LPVs. Procedure time was 60,0 min (IQR 51-70). Fluoroscopy time was 58,5 s (35-97,5). First pass isolation was obtained in 72 (90%) of the RPVs and 75 (93,8%) of the LPVs. Conclusions the present study, assessing a novel, personalized protocol for radiofrequency titration during atrial fibrillation ablation, shows a high rate of first pass isolation with a lower need for RF energy delivery and lower procedure requirements, as compared to previous PV ablation protocols. Further studies are needed to evaluate the long-term results of this approach. Abstract Figure. LAWT-map Visitag points with tailored AI


Sign in / Sign up

Export Citation Format

Share Document