Current status of MEK inhibitors in the treatment of plexiform neurofibromas

2020 ◽  
Vol 36 (10) ◽  
pp. 2443-2452 ◽  
Author(s):  
Andrea M. Gross ◽  
Eva Dombi ◽  
Brigitte C. Widemann
2019 ◽  
Vol 50 (05) ◽  
pp. 300-303 ◽  
Author(s):  
Pia Vaassen ◽  
Nikola Dürr ◽  
Andreas Röhrig ◽  
Rainer Willing ◽  
Thorsten Rosenbaum

AbstractPlexiform neurofibromas are congenital peripheral nerve sheath tumors characteristic of neurofibromatosis type 1 (NF1)—a frequent neurocutaneous disorder caused by mutations of the NF1 tumor suppressor gene. Since plexiform neurofibromas are a major cause of the burden of disease and may also progress to malignancy, many efforts have been undertaken to find a cure for these tumors. However, neither surgery nor medication has so far produced a breakthrough therapeutic success. Recently, a clinical phase I study reported significant shrinkage of plexiform neurofibromas following treatment with the MEK inhibitor selumetinib. Here, we report an 11-year-old NF1 patient with a large plexiform neurofibroma of the neck that had led to a sharp-angled kinking of the cervical spine and subsequent myelopathy. Although surgical stabilization of the cervical vertebral column was urgently recommended, the vertebral column was inaccessible due to extensive tumor growth. In this situation, treatment with the MEK inhibitor trametinib was initiated which resulted in a 22% reduction in tumor volume after 6 months of therapy and finally enabled surgery. These data show that MEK inhibitors may not lead to complete disappearance of NF1-associated plexiform neurofibromas but can be an essential step in a multimodal therapeutic approach for these tumors. The course of our patient suggests that MEK inhibitors are likely to play a significant role in providing a cure for one of the most devastating manifestations of NF1.


1966 ◽  
Vol 25 ◽  
pp. 266-267
Author(s):  
R. L. Duncombe

An examination of some specialized lunar and planetary ephemerides has revealed inconsistencies in the adopted planetary masses, the presence of non-gravitational terms, and some outright numerical errors. They should be considered of temporary usefulness only, subject to subsequent amendment as required for the interpretation of observational data.


Author(s):  
Martin Peckerar ◽  
Anastasios Tousimis

Solid state x-ray sensing systems have been used for many years in conjunction with scanning and transmission electron microscopes. Such systems conveniently provide users with elemental area maps and quantitative chemical analyses of samples. Improvements on these tools are currently sought in the following areas: sensitivity at longer and shorter x-ray wavelengths and minimization of noise-broadening of spectral lines. In this paper, we review basic limitations and recent advances in each of these areas. Throughout the review, we emphasize the systems nature of the problem. That is. limitations exist not only in the sensor elements but also in the preamplifier/amplifier chain and in the interfaces between these components.Solid state x-ray sensors usually function by way of incident photons creating electron-hole pairs in semiconductor material. This radiation-produced mobile charge is swept into external circuitry by electric fields in the semiconductor bulk.


2021 ◽  
Author(s):  
Yuanhong Ma ◽  
Shao-Jie Lou ◽  
Zhaomin Hou

This review article provides a comprehensive overview to recognise the current status of electron-deficient boron-based catalysis in C–H functionalisations.


Sign in / Sign up

Export Citation Format

Share Document