Biomechanics of artificial intervertebral disc with different materials using finite element method

2018 ◽  
Vol 23 (19) ◽  
pp. 9215-9236 ◽  
Author(s):  
Lamia Nabil Omran ◽  
Kadry Ali Ezzat ◽  
Mohamed Elhoseny ◽  
Aboul Ella Hassanien
Author(s):  
Samir Zahaf ◽  
Said Kebdani

Orthopedic fixation devices are widely used in treatment of spinal diseases. It is expected that application of dynamic stabilization confers valuable movement possibility besides its main role of load bearing. Comparative investigation between pedicle screw model rigid fixation and (B Dyne, Elaspine, Bioflex, Coflexe rivet) models dynamic fixation systems may elucidate the efficacy of each design. The goal of the present study is to evaluate the efficacy of five fixation systems mounted on L4-L5 motion segment. In this numerical study, a 3D precious model of L4, L5 and their intervertebral disc has been employed based on CT images. five fixation devices have been also implanted internally to the motion segment. Finite element method was used to evaluate stress distribution in the disc and determine the overall displacement of the segment as a measure of movement possibility. The results show that The Coflex rivet implantation can provide stability in all motions and reduce disc annulus stress at the surgical segment (L4-L5), on the other hand, Maximum stress in the disc has been observed in dynamic systems but within the safe range. The greater movement of the motion segment has been also appeared in dynamic fixations. Existence of the fixation systems reduced the stress on the intervertebral disc which might be exerted in intact cases. Use of the fixation devices can considerably reduce the load on the discs and prepare conditions for healing of the injured ones. Furthermore, dynamic modes of fixation confer possibility of movement to the motion segments in order to facilitate the spinal activities.


Author(s):  
Keisuke Sasagawa ◽  
Masafumi Oda ◽  
Keiko Katsuyama ◽  
Kazuhiro Hasegawa ◽  
Toshiaki Hara ◽  
...  

2015 ◽  
Vol 15 (3) ◽  
pp. 57-66
Author(s):  
W. Kajzer ◽  
A. Kajzer ◽  
I. Pindycki

Abstract Dysfunctions of the vertebral column belong to a group of civilisation diseases and they affect approximately 80% of population. The underlying cause is modern (sedentary) lifestyle, low locomotive activity of people and frequent motor vehicle and sports accidents. Despite civilisation’s progress, no injury prophylactics or prevention of dysfunctions of the vertebral column have been introduced. The key element influencing function of the vertebral column is the intervertebral disc. It enables multidimensional movements and constitutes a basic connective element between the joints of the vertebral column. It also enables performing basic daily activities. Acting as a “damper”, it cushions vibrations and transmits loads between the vertebrae. One of the diseases affecting the intervertebral disc is discopathy. This is the most common degenerative disease, which can be treated by both conservative and surgical treatment. After removal of the damaged disc, it can be replaced by an adequate implant, which will assume its function. The implant will be expected to restore the vertebral column motor function, as well as to eliminate the pain resulting from compression of the spine caused by the damaged disc. This paper presents a biomechanical analysis using the finite element method for the L2-L3 vertebrae system with natural intervertebral disc, and the L2-L3 – implant of the intervertebral disc system. Two cases of the system vertebrae-implant were analysed which differed in the placement of the artificial disc in the intervertebral space. Within the conducted analysis, the state of displacement, strain and stress of reduced analysed systems and their individual elements was determined. A comparative analysis of the results and calculations was performed, also conclusions and observations were formulated, constituting a starting point for building more advanced calculation models and further analyses of such implants.


Nanoscale ◽  
2019 ◽  
Vol 11 (43) ◽  
pp. 20868-20875 ◽  
Author(s):  
Junxiong Guo ◽  
Yu Liu ◽  
Yuan Lin ◽  
Yu Tian ◽  
Jinxing Zhang ◽  
...  

We propose a graphene plasmonic infrared photodetector tuned by ferroelectric domains and investigate the interfacial effect using the finite element method.


Sign in / Sign up

Export Citation Format

Share Document