scholarly journals Fragility curves for non-engineered masonry buildings in developing countries derived from real data based on structural surveys and laboratory tests

2021 ◽  
Author(s):  
Viviana Iris Novelli ◽  
Raffaele De Risi ◽  
Ignasio Ngoma ◽  
Innocent Kafodya ◽  
Panos Kloukinas ◽  
...  

AbstractMalawi is located within the southern branch of the active East African Rift System, where earthquakes of moment magnitude (Mw) 7.0 or greater can occur along major faults. The majority of dwellings in the country are non-engineered unreinforced masonry constructions, built by local artisans with little input from engineers. These constructions are highly vulnerable to seismic events due to poor-quality materials and lack of construction detailing. This study presents a new methodology to assess the seismic fragility curves of typical dwellings located in the Central and Southern Malawi. On-site inspections of buildings are carried out to assess geometrical and structural features of 646 façades, and an experimental campaign is performed to characterise the mechanical properties of local construction materials. The collected data allow the identification of different building typologies in terms of quality of materials and construction techniques. The critical failure modes for each of the inspected façade at their ultimate limit state are evaluated analytically. Damage limit states are defined and adopted to derive simplified Static Push-Over (SPO) curves, transformed into incremental dynamic analysis (IDA) curves by using SPO2IDA. The IDA curves are then used to obtain fragility curves for the specific damage limit states. The fragility curves presented herein are the first to be calculated for these building typologies, based on local data, and unfortunately, they show that buildings in Malawi are far more vulnerable to earthquakes than estimated from previously available international reference data. The fragility curves developed in this study may prove useful for assessing the seismic risk of these building typologies in Malawi and other East African countries.

Author(s):  
Mohamed S. Abu-Yosef ◽  
Ezzeldin Y. Sayed-Ahmed ◽  
Emam A. Soliman

Steel connections transferring axial and shear forces in addition to bending moment and/or torsional moment are widely used in steel structures. Thus, design of such eccentric connections has become the focal point of any researches. Nonetheless, behavior of eccentric connections subjected to shear forces and torsion in the ultimate limit state is still ambiguous. Most design codes of practice still conservatively use the common elastic analysis for design of the said connections even in the ultimate limit states. Yet, there are some exceptions such as the design method proposed by CAN/CSA-S16-14 which gives tabulated design aid for the ultimate limit state design of these connections based on an empirical equation that is derived for ¾ inch diameter A325 bearing type bolts and A36 steel plates. It was argued that results can also be used with a margin of error for other grade bolts of different sizes and steel of other grades. As such, in this paper, the performance of bolted connection subject to shear and torsion is experimentally investigated. The behavior, failure modes and factors affecting both are scrutinized. Twelve connections subject to shear and torsion with different bolts configurations and diameters are experimentally tested to failure. The accuracy of the currently available design equations proposed is compared to the outcomes of these tests.


2017 ◽  
Author(s):  
Sara Mana ◽  
◽  
Merry Yue Cai ◽  
Catherine C. Beck ◽  
Steven L. Goldstein

2020 ◽  
Author(s):  
Alexis Nutz ◽  
◽  
Mathieu Schuster ◽  
Doris Barboni ◽  
Ghislain Gassier ◽  
...  

Author(s):  
A. Sandoli ◽  
G. P. Lignola ◽  
B. Calderoni ◽  
A. Prota

AbstractA hybrid seismic fragility model for territorial-scale seismic vulnerability assessment of masonry buildings is developed and presented in this paper. The method combines expert-judgment and mechanical approaches to derive typological fragility curves for Italian residential masonry building stock. The first classifies Italian masonry buildings in five different typological classes as function of age of construction, structural typology, and seismic behaviour and damaging of buildings observed following the most severe earthquakes occurred in Italy. The second, based on numerical analyses results conducted on building prototypes, provides all the parameters necessary for developing fragility functions. Peak-Ground Acceleration (PGA) at Ultimate Limit State attainable by each building’s class has been chosen as an Intensity Measure to represent fragility curves: three types of curve have been developed, each referred to mean, maximum and minimum value of PGAs defined for each building class. To represent the expected damage scenario for increasing earthquake intensities, a correlation between PGAs and Mercalli-Cancani-Sieber macroseismic intensity scale has been used and the corresponding fragility curves developed. Results show that the proposed building’s classes are representative of the Italian masonry building stock and that fragility curves are effective for predicting both seismic vulnerability and expected damage scenarios for seismic-prone areas. Finally, the fragility curves have been compared with empirical curves obtained through a macroseismic approach on Italian masonry buildings available in literature, underlining the differences between the methods.


1989 ◽  
Vol 16 (2) ◽  
pp. 124-139 ◽  
Author(s):  
Robert G. Driver ◽  
D. J. Laurie Kennedy

Design standards provide little information for the design of I-shaped steel beams not loaded through the shear centre and therefore subjected to combined flexure and torsion. In particular, methods for determining the ultimate capacity, as is required in limit states design standards, are not presented. The literature on elastic analysis is extensive, but only limited experimental and analytical work has been conducted in the inelastic region. No comprehensive design procedures, applicable to limit states design standards, have been developed.From four tests conducted on cantilever beams, with varying moment–torque ratios, it is established that the torsional behaviour has two distinct phases, with the second dominated by second-order geometric effects. This second phase is nonutilizable because the added torsional restraint developed is path dependent and, if deflections had been restricted, would not have been significant. Based on the first-phase behaviour, a normal and shearing stress distribution on the cross section is proposed. From this, a moment–torque ultimate strength interaction diagram is developed, applicable to a number of different end and loading conditions. This ultimate limit state interaction diagram and serviceability limit states, based on first yield and on distortion limitations, provide a comprehensive design approach for these members. Key words: beams, bending moment, flexure, inelastic, interaction diagram, I-shaped, limit states, serviceability, steel, torsion, torque, ultimate.


1996 ◽  
Vol 33 (5) ◽  
pp. 815-821 ◽  
Author(s):  
A B Schriver ◽  
A J Valsangkar

Recently, the limit states approach using factored strength has been recommended in geotechnical design. Some recent research has indicated that the application of limit states design using recommended load and strength factors leads to conservative designs compared with the conventional methods. In this study the influence of sheet pile wall geometry, type of water pressure distribution, and different methods of analysis on the maximum bending moment and achor rod force are presented. Recommendations are made to make the factored strength design compatible with conventional design. Key words: factored strength, working stress design, ultimate limit state design, anchored sheet pile wall, bending moment, anchor rod force.