Combined flexure and torsion of I-shaped steel beams

1989 ◽  
Vol 16 (2) ◽  
pp. 124-139 ◽  
Author(s):  
Robert G. Driver ◽  
D. J. Laurie Kennedy

Design standards provide little information for the design of I-shaped steel beams not loaded through the shear centre and therefore subjected to combined flexure and torsion. In particular, methods for determining the ultimate capacity, as is required in limit states design standards, are not presented. The literature on elastic analysis is extensive, but only limited experimental and analytical work has been conducted in the inelastic region. No comprehensive design procedures, applicable to limit states design standards, have been developed.From four tests conducted on cantilever beams, with varying moment–torque ratios, it is established that the torsional behaviour has two distinct phases, with the second dominated by second-order geometric effects. This second phase is nonutilizable because the added torsional restraint developed is path dependent and, if deflections had been restricted, would not have been significant. Based on the first-phase behaviour, a normal and shearing stress distribution on the cross section is proposed. From this, a moment–torque ultimate strength interaction diagram is developed, applicable to a number of different end and loading conditions. This ultimate limit state interaction diagram and serviceability limit states, based on first yield and on distortion limitations, provide a comprehensive design approach for these members. Key words: beams, bending moment, flexure, inelastic, interaction diagram, I-shaped, limit states, serviceability, steel, torsion, torque, ultimate.

1996 ◽  
Vol 33 (5) ◽  
pp. 815-821 ◽  
Author(s):  
A B Schriver ◽  
A J Valsangkar

Recently, the limit states approach using factored strength has been recommended in geotechnical design. Some recent research has indicated that the application of limit states design using recommended load and strength factors leads to conservative designs compared with the conventional methods. In this study the influence of sheet pile wall geometry, type of water pressure distribution, and different methods of analysis on the maximum bending moment and achor rod force are presented. Recommendations are made to make the factored strength design compatible with conventional design. Key words: factored strength, working stress design, ultimate limit state design, anchored sheet pile wall, bending moment, anchor rod force.


2021 ◽  
Vol 11 (1) ◽  
pp. 6708-6713
Author(s):  
H. Benzeguir ◽  
S. M. Elachachi ◽  
D. Nedjar ◽  
M. Bensafi

Dysfunctions and failures of buried pipe networks, like sewer networks, are studied in this paper from the point of view of structural reliability and heterogeneity of geotechnical conditions in the longitudinal direction. Combined soil spatial variability and Peak Ground Acceleration (PGA) induce stresses and displacements. A model has been developed within the frame of geostatistics and a mechanical description of the soil–structure interaction of a set of buried pipes with connections resting on the soil by a two-parameter model (Pasternak model). Structural reliability analysis is performed considering two limit states: Serviceability Limit State (SLS), related to large "counter slope" in a given pipe, and Ultimate Limit State (ULS), corresponding to bending moment.


Author(s):  
Mohamed S. Abu-Yosef ◽  
Ezzeldin Y. Sayed-Ahmed ◽  
Emam A. Soliman

Steel connections transferring axial and shear forces in addition to bending moment and/or torsional moment are widely used in steel structures. Thus, design of such eccentric connections has become the focal point of any researches. Nonetheless, behavior of eccentric connections subjected to shear forces and torsion in the ultimate limit state is still ambiguous. Most design codes of practice still conservatively use the common elastic analysis for design of the said connections even in the ultimate limit states. Yet, there are some exceptions such as the design method proposed by CAN/CSA-S16-14 which gives tabulated design aid for the ultimate limit state design of these connections based on an empirical equation that is derived for ¾ inch diameter A325 bearing type bolts and A36 steel plates. It was argued that results can also be used with a margin of error for other grade bolts of different sizes and steel of other grades. As such, in this paper, the performance of bolted connection subject to shear and torsion is experimentally investigated. The behavior, failure modes and factors affecting both are scrutinized. Twelve connections subject to shear and torsion with different bolts configurations and diameters are experimentally tested to failure. The accuracy of the currently available design equations proposed is compared to the outcomes of these tests.


Author(s):  
Inge Lotsberg ◽  
Gunnar Solland

The design of the grouted connections in jacket structures has until recently been based on a control of capacity with respect to axial force in the pile while the effect of the bending moment has been neglected, ref. ISO 19902 (2007). In later design of grouted connections it is observed that the moments in the piles can contribute to more than two times larger stress in the pile than that due to axial load only. A significant moment can hardly be transferred from the pile to the sleeve without sliding of the steel against the grout. This sliding is considered to increase with increasing diameter of the pile. Therefore it is difficult to develop design criteria based on small scale testing. The contact pressure between grout and steel will lead to compressive and tensile stresses in the grout. This requires design criteria for compressive stress and tensile stress in the grout. ISO 19902 do not require fatigue assessment of grouted connections subjected to wave loading. This was based on a review and assessment of jackets present in the Lloyds database at the time the design formulation was developed. It was assessed that fatigue assessment was not required as long as design was performed with respect to the Ultimate Limit State. However, it is now judged that fatigue is important for jackets with significant dynamic load that exceeds the axial and bending moment from permanent loads. A review of design standards for grouted connections in jacket structures has shown that there is a need for more relevant test data and revisions of these standards such as ISO 19902 in order to assure reliable design with respect to all potential failure modes.


2007 ◽  
Vol 34 (9) ◽  
pp. 1029-1037 ◽  
Author(s):  
F M Bartlett

This paper presents the rationale for increasing the resistance factor for concrete in compression in the 2004 edition of the Canadian Standards Association (CSA) standard A23.3, Design of concrete structures, from 0.60 to 0.65 and for precast concrete produced in CSA-certified plants from 0.65 to 0.70. The new values are supported by a probability-based resistance factor calibration and an investigation of their impact in the context of current American standards and past editions of A23.3. The work was initiated because parameters for the rectangular concrete stress block introduced in the 1994 edition of A23.3 give smaller factored resistances for concretes with strengths between 20 and 40 MPa. Minimum target reliability indices for components that fail suddenly are maintained using the new resistance factors. In the regions of compressive force – bending moment interaction diagrams that are controlled by the resistance factor for concrete, the factored resistances computed using the 2004 edition of A23.3 are similar to those of current American design criteria.Key words: code calibration, compression-initiated failure, concrete, interaction diagram, rectangular stress block, ultimate limit state.


2013 ◽  
Vol 6 (1) ◽  
pp. 55-74 ◽  
Author(s):  
J. E. Campuzano ◽  
R. de Castro ◽  
S. Ávila ◽  
G. Doz

This paper is about the design and construction of a platform for dynamic tests especially with people jumping, walking, etc. Initially it was tried to find out projects already implemented in platforms and dynamic tests and to study the loads produced by movement of people on slabs and the structural response to these loads. The limits established by different standards have been also studied for these dynamic responses, taking into account the ultimate limit state, as well as the structure in service, since the human body is very sensitive to structural vibrations. Parametric studies were performed considering various configurations of slabs (different spans, thicknesses and conditions of support) have been done, looking for a configuration that could have natural frequency close to the frequencies of the human loads. The slab should have dimensions compatible with the available physical space, fundamental frequency below 5 Hz and maximum immediate deflection compatible with the indications of the Brazilian standard NBR6118: 2007. Based on these criteria was chosen a rectangular structure consists of a solid reinforced concrete rectangular slab studded in two opposite edges of steel beams with shear connectors type U. The other two edges are free. The steel beams supporting the slab, in turn, are supported on eight metal profiles (two in each corner of the slab) that are supported on two to two short columns of steel profile H. Profiles U in steel are welded to four columns, forming a horizontal frame. Numerical analysis of the dynamic test platform have been performed for free and forced vibration, for obtaining the natural frequencies and corresponding vibration modes, considering the self-weight of the structure and the load that simulates people's weight. After obtaining a structural configuration that fulfilled the stipulated requirements, the design of the slab taking into account the recommendations of the Brazilian standard NBR6118: 2007. The platform was built and has been done a preliminary experimental study to obtain the first natural frequencies.


2019 ◽  
Vol 2019 ◽  
pp. 1-16 ◽  
Author(s):  
Bin Wang ◽  
Wenzhe Cai ◽  
Qingxuan Shi

Sectional deformation quantities, such as curvature and ductility, are of prime significance in the displacement-based seismic design and performance evaluation of structural members. However, few studies on the estimates of curvatures at different limit states have been performed on asymmetric flanged walls. In this paper, a parametric study was performed for a series of T-shaped wall cross-sections based on moment-curvature analyses. By investigating the effects of the axial load ratio, reinforcement content, material properties, and geometric parameters on curvatures at the yield and ultimate limit state, we interpret the variation in curvature with different influencing factors in detail according to the changes of the neutral axis depth. Based on the regression analyses of the numerical results of 4941 T-shaped cross-sections, simple expressions to estimate the yield curvature and ultimate curvature for asymmetric flanged walls are developed, and simplified estimates of the ductility capacity including curvature ductility and displacement ductility are further deduced. By comparing with the experimental results, we verify the accuracy of the proposed formulas. Such simple expressions will be valuable for the determination of the displacement response of asymmetric flanged reinforced concrete walls.


1996 ◽  
Vol 12 (1) ◽  
pp. 129-143 ◽  
Author(s):  
Richard A. Behr ◽  
Abdeldjelil Belarbi

An ongoing effort is being made at the University of Missouri-Rolla to develop standard laboratory test methods and codified design procedures for architectural glass under seismic loadings. Recent laboratory work has yielded some promising results regarding the development of an appropriate seismic test method for architectural glass, as well as identifying ultimate limit states that quantify the seismic performance and damage thresholds of various glass types. Specifically, a straightforward “crescendo-like” in-plane dynamic racking test, performed at a constant frequency, has been employed successfully. Two ultimate limit states for architectural glass have been defined: (1) a lower ultimate limit state corresponding to major glass crack pattern formation; and (2) an upper limit state corresponding to significant glass fallout. Early crescendo tests have yielded distinct and repeatable ultimate limit state data for various storefront glass types tested under dynamic racking motions. Crescendo tests will also be used to identify and quantify serviceability limit states for architectural glass and associated glazing components under dynamic loadings. These limit state data will support the development of rational design procedures for architectural glass under seismic loadings.


Author(s):  
James P. Doherty ◽  
Barry M. Lehane

This paper describes an automated algorithm for determining the length and diameter of monopile foundations subject to lateral loads with the aim of minimising the pile weight, whilst satisfying both ultimate and serviceability limit states. The algorithm works by wrapping an optimisation routine around a finite element p - y model for laterally loaded piles. The objective function is expressed as a function representing the pile volume, while the ultimate limit state and serviceability limit states are expressed as optimisation constraints. The approach was found to be accurate and near instantaneous when compared to manual design procedures and may improve design outcomes and reduce design time and costs.


Author(s):  
Jeom Kee Paik ◽  
Bong Ju Kim ◽  
Jung Kwan Seo

The aim of the present paper is to evaluate the ultimate limit state performance of an AFRAMAX-class hypothetical double hull oil tanker structure designed by IACS CSR (Common Structural Rules) method, compared with the same-class/type tanker structure designed by IACS pre-CSR method. The ultimate strengths of stiffened plate structures in deck and bottom parts under combined in-plane and out-of-plane actions, and hull girder against vertical bending moment, are computed for the two designs, and the resulting computations are compared. ALPS/ULSAP program is used for the ultimate limit state assessment of stiffened plate structures, while ALPS/HULL program is employed for the progressive hull collapse analysis. ANSYS nonlinear FEA method, which uses more refined technology, is also used for the same purpose. The insights and developments obtained from the present study are addressed.


Sign in / Sign up

Export Citation Format

Share Document