Damage of lithium-disilicate all-ceramic restorations by an experimental self-adhesive resin cement used as core build-ups

2014 ◽  
Vol 19 (2) ◽  
pp. 281-288 ◽  
Author(s):  
G. Sterzenbach ◽  
G. Karajouli ◽  
R. Tunjan ◽  
T. Spintig ◽  
K. Bitter ◽  
...  
2010 ◽  
Vol 18 (3) ◽  
pp. 244-248 ◽  
Author(s):  
Guilherme B Guarda ◽  
Luciano S Gonçalves ◽  
Américo B Correr ◽  
Rafael R Moraes ◽  
Mário A.C Sinhoreti ◽  
...  

2022 ◽  
Vol 12 (3) ◽  
pp. 533-543
Author(s):  
Nasser M. Alahmari ◽  
Hafiz A. Adawi ◽  
Mohammed M. Al, Moaleem ◽  
Mashael M. A. Alqahtani ◽  
Lama A. A. Alkahtani ◽  
...  

The aim of this study was to evaluate if adhesion technology with CAD/CAM can compensate for the reduction of occluso cervical preparation heights using different types of dental cement. The de-bonding failure types were then assessed. Here, 72 caries-free extracted human premolar teeth were prepared to have a remaining occlusal height of two, three, and four mm. IPS e.max lithium disilicate CAD/CAM crowns were cemented with adhesive resin cement Panavia SA, self-adhesive resin cement, RelyX Unicem Aplicap, and zinc phosphate cement. The cementation techniques were based on the manufacturer’s instructions. After thermocycling, all samples were tested for tensile bond strength via an Instron machine. One-way analysis of variance (ANOVA) with post hoc testing (P < 0.05) was performed. The means TBS for the two, three, and four-mm OCHP groups were 2.72±0.69, 3.06±0.82, and 3.25±0.79.0 MPa; ARC, SARC, and ZPC were 3.41±0.51, 3.45±0.41, 2.08±0.35 MPa, respectively with significant differences in both. The mixed cement had failures in the resin cement groups. Failure was predominantly cohesive in the zinc phosphate group. Resin cement had the highest SBS values versus ZPC values when both bonded to lithium disilicate crowns with different occlusal heights. The failure of the adhesive to the crown and/or to the tooth were the highest for the four types of resin cement. Around 25% were cohesive failures with resin cement, but this was predominately adhesive in crowns in zinc phosphate regardless of the preparation heights.


2016 ◽  
Vol 17 (2) ◽  
pp. 149-153 ◽  
Author(s):  
Cristina Parise Gré ◽  
Renan C de Ré Silveira ◽  
Shizuma Shibata ◽  
Carlo TR Lago ◽  
Luiz CC Vieira

ABSTRACT Aim This study evaluated the influence of a silane-coupling agent on the bond strength of a self-adhesive cement and a conventional resin cement to a lithium disilicate glass ceramic. Materials and methods A total of eight ceramic blocks were fabricated and divided into four groups (n = 2). In groups 1 and 3, ceramic surfaces were etched with hydrofluoric acid 10% for 20 seconds, rinsed for 30 seconds, and air-dried. One layer of a silane agent was applied onto all ceramic specimens and air-dried for 30 seconds. In groups 2 and 4, ceramic surfaces were etched with hydrofluoric acid, rinsed, and air-dried without application of the silane-coupling agent. The ceramic blocks were bonded to a block of composite with a self-adhesive resin cement or with a conventional resin cement, according to the manufacturer's instructions. After 24 hours in distilled water at 37°C, the specimens were sectioned perpendicular to the bonding interface area to obtain beams with a bonding area of 0.8 mm2 and submitted to a microtensile bond strength test at a crosshead speed of 0.5 mm/min. Data were statistically analyzed with one-way analysis of variance and the Games–Howell post hoc test (p = 0.05). Fractured specimens were examined under optical microscopy at 40× magnification. Results Silanization resulted in higher microtensile bond strength compared to groups without silane. No significant differences were found between the conventional resin cement and the self-adhesive resin cement with silane agent (p = 0.983), and without silane agent (p = 0.877). Conclusion Silanization appears to be crucial for resin bonding to a lithium disilicate-based ceramic, regardless of the resin cement used. The self-adhesive resin cement performed as well as the conventional resin cement. Clinical significance Applying one layer of a silane-coupling agent after etching the ceramic surface with hydrofluoric acid 10% enhanced the bond strength between resin cements and a glass ceramic. How to cite this article Gré CP, de Ré Silveira RC, Shibata S, Lago CTR, Vieira LCC. Effect of Silanization on Microtensile Bond Strength of Different Resin Cements to a Lithium Disilicate Glass Ceramic. J Contemp Dent Pract 2016;17(2):149-153.


2018 ◽  
Vol 119 (5) ◽  
pp. 826-832 ◽  
Author(s):  
Glen H. Johnson ◽  
Xavier Lepe ◽  
Amanda Patterson ◽  
Oliver Schäfer

2016 ◽  
Vol 31 (3) ◽  
pp. 242-249
Author(s):  
Ziad Nawaf Al-Dwairi ◽  
Khalil Aleisa ◽  
Abdulhameed Al-Beshr ◽  
Yazeed Al-Habdan ◽  
Faisal Al-Harbi ◽  
...  

2014 ◽  
Vol 2 (1) ◽  
pp. 37
Author(s):  
César Dalmolin Bergoli ◽  
Marina Amaral ◽  
Emília Pithan Prochnow ◽  
Mariane Konzen ◽  
Luiz Felipe Valandro

Introduction: Hot pressed ceramics is usually used in prosthodontics as restorative material, being important to evaluate which cementation strategy generates better union between this ceramic and dental structure.Aim: To evaluate the effect of mechanical cycling on bond strength between a hot-pressed glass-ceramic and dentin, using different cementation strategies. Materials and Methods: Sixty molar teeth with flat oclusal dentin surface were allocated in six groups: Gr1-Self-adhesive resin cement; Gr2-Self-adhesive resin cement + Mechanical Cycling(MC); Gr3-Total etch adhesive + conventional resin cement; Gr4-Total etch adhesive + conventional resin cement + MC; Gr5-Self-etching adhesive + resin cement with MDP; Gr6-Self-etching adhesive + resin cement with MDP + MC. Sixty hot-pressed leucite-based all-ceramic restorations were cemented as recommended by manufacturers. Bar-shaped samples of 1 mm2 of cross-sectional bonding area were obtained and the microtensile test were conducted. Data were submitted to ANOVA-two way and Tukey test (α=0.05). Results: Mechanical cycling did not influence the results (p=0.1576), but cementation strategy (p=0.0419) affected. RelyX U100 showed the lowest values (7.0±5.0), RelyX ARC showed highest values (10.6±4.5) and Panavia F showed intermediary values (8.5±5.1). Conclusion: 2.106 million cycles are not able to damage the union between resin cement and dentin; conventional adhesive cementation strategy promoted the more stable interfaces between restoration and dentin.


2020 ◽  
Vol 10 (8) ◽  
pp. 2696
Author(s):  
Satheesh B. Haralur ◽  
Alaa Ali Alamri ◽  
Shatha Abdulrahman Alshehri ◽  
Danyah Saeed Alzahrani ◽  
Mohammed Alfarsi

Endocrowns are primarily recommended in a molar region with a standardized preparation design. The aim of the study was to evaluate the effect of different occlusal preparation depths, pulp chamber-radicular extension, and all-ceramic materials on the fracture resistance of premolar endocrowns. Ninety human premolar teeth were root canal treated, randomly divided into three main groups according to all-ceramic material used for fabrication as Lithium Disilicate (LD) ceramic, Polymer infiltrated ceramic (PIC) and High translucency zirconia (HTZ). They were further subdivided into three subgroups (n = 10) according to preparation design of 2 mm occlusal reduction, 4.5 mm occlusal reduction and 4.5 mm occlusal reduction with 2 mm radicular extension. The endocrowns from respective restorative materials were fabricated, surface conditioned, and cemented with self-adhesive resin cement. All samples were thermocycled for 5000 cycles and subjected to compressive static load at 45° angluation with the cross-head speed of 0.5 mm/minute until the fracture. The mean fracture resistance of LD ceramic at 2 mm, 4.5 mm thickness and radicular extension was 62.55 MPa, 45.80 MPa, 74.27 MPa respectively. The corresponding values for the PIC and HTZ ceramics were 26.30 MPa, 21.65 MPa, 25.66 Mpa and 23.47 MPa, 27.30 MPa, 37.29 MPa respectively. The LD ceramic and greater extension inside the pulp chamber had higher fracture resistance.


Sign in / Sign up

Export Citation Format

Share Document