Friction anlysis of large diameter steel cylinder penetration process using 3D-DEM

2021 ◽  
Vol 23 (2) ◽  
Author(s):  
Xiaobin Ding ◽  
Yu Shi ◽  
Rui Chen ◽  
Mi Zhou
2020 ◽  
Vol 198 ◽  
pp. 03026
Author(s):  
Chang-yi Yu ◽  
Ming-yue Lu

The stability mechanism of large-diameter steel cylinder under fill load has not yet formed a complete theory. In order to calculate the stability of the steel cylinder island arm structure in a certain project, the limit equilibrium and finite element method are used in this paper. The limit equilibrium method is based on the limit equilibrium of the soil inside and outside the steel cylinder, taking into account the earth pressure and friction force on the cylinder, and using moment equilibrium to calculate its stability coefficient. Secondly, the finite element strength reduction method is adopted to analyze the stability of the steel cylinder island arm structure by using strength parameters to correlate with the temperature field and changing the boundary conditions of the temperature field. The results and analysis methods of this paper provide references for the construction and design of the same type of projects.


Author(s):  
A. Yamada ◽  
A. Shibano ◽  
K. Harasawa ◽  
T. Kobayashi ◽  
H. Fukuda ◽  
...  

A newly developed digital scanning electron microscope, the JSM-6300, has the following features: Equipped with a narrower conical objective lens (OL), it allows high resolution images to be obtained easily at a short working distance (WD) and a large specimen tilt angle. In addition, it is provided with automatic functions and digital image processing functions for ease of operation.Conical C-F lens: The newly developed conical C-F objective lens, having low aberration characteristics over a wide WD range, allows a large-diameter (3-inch) specimen to be tilted up to 60° at short WD, and provides images with low magnifications starting at 10*. On the bottom of the lens, a p n junction type detector is provided to detect backscattered electrons (BE) from the specimen. As the narrower conical 0L increases the secondary electron (SE) detector's field intensity on the specimen surface, high SE image quality is obtained.


2020 ◽  
Vol 7 (2) ◽  
pp. 21-28
Author(s):  
SALI RADZHAPOV ◽  
◽  
RUSTAM RAKHIMOV ◽  
BEGJAN RADZHAPOV ◽  
MARS ZUFAROV

The article describes the developed radiometer for Express measurement of alpha radiation of radioactive elements based on a large-diameter silicon detector. The main element of the PPD detector is made using computer mathematical modeling of all stages of the technological process of manufacturing detectors, taking into account at each stage the degree of influence of the properties of the initial silicon on the electrophysical and radiometric characteristics of the detector. Detectors are manufactured for certain types of devices. The developed radiometer is designed to measure alpha radiation of natural isotopes (238U, 234U, 232Th, 226Ra, 222Rn, 218Po, 214Bi, etc.) in various environments. It also shows the principle of operation of the device, provides a block diagram of the measuring complex, describes the electronic components of the radiometer, as well as the block diagram. Signal transformations (spectrum transfer, filtering, accumulation) are implemented programmatically on the basis of a digital processing module. The device can detect the presence of specific elements in various environments, as well as protect people from the harmful effects of adverse radiation and can be used both in the field and stationary.