Determination of Inorganic Anions by Capillary IC Using Hexadimethrine Bromide-Modified Silica Stationary Phases

2011 ◽  
Vol 73 (5-6) ◽  
pp. 501-506 ◽  
Author(s):  
Li Rong ◽  
Zhiguo Liu ◽  
Menglin Ma ◽  
Lee Wah Lim ◽  
Toyohide Takeuchi
2019 ◽  
Vol 19 (1) ◽  
pp. 191
Author(s):  
Roza Linda ◽  
Mohamad Rafi ◽  
Lee Wah Lim ◽  
Toyohide Takeuchi

Tetraethylene glycol monomethyl ether (TEGMM) and tetraethylene glycol (TEG) modified silica were synthesized and used in capillary liquid chromatography as stationary phases. The stationary phases were prepared by chemically bonding TEGMM or TEG on silica via reaction with 3-glycidyloxypropyltrimethoxysilane. The present stationary phases were successfully used for the separation of several inorganic anions and phenolic compounds. The TEG-modified silica stationary phase had a better selectivity and higher retention for five anions compared to TEGMM-modified silica stationary phase. The repeatability of retention time for the five anions was satisfactory on both stationary phases. By using 2 mM sodium chloride as eluent, the relative standard deviation values were in ranging from 0.68–3.21 and 2.00–2.16% for analytes in the TEG-and TEGMM-bonded stationary phase, respectively. It was found that the TEG-bonded stationary phase had hydrophilic properties due to the presence of the hydroxyl group at the end of the TEG chains.


2008 ◽  
Vol 57 (12) ◽  
pp. 991-999 ◽  
Author(s):  
Xiao-Lin Jiang ◽  
Li Rong ◽  
Atsushi Suzuki ◽  
Masahiro Kobayashi ◽  
Lee Wah Lim ◽  
...  

1975 ◽  
Vol 58 (5) ◽  
pp. 1051-1061
Author(s):  
William P Cochrane ◽  
James F Lawrence ◽  
Young W Lee ◽  
Ronald B Maybury ◽  
Brian P Wilson

Abstract An interlaboratory investigation of technical chlordane residues in food crops was carried out to determine the most practical and consistent method of reporting results. Using a technical chlordane reference standard, 8 gas chromatographic stationary phases were studied for their resolution capabilities. The best separations were obtained with SE-30 and its OV-1 equivalent. Using these columns and electron capture detection, potatoes and carrots from supervised field experiments were analyzed in duplicate and quantitated by using 4 methods of calculation. The data were statistically treated to determine the precision and bias for each method. Also, 1 sample was analyzed in duplicate on 2 different occasions by 6 laboratories to substantiate the initial conclusions. Based on the criterion of high precision it is suggested that a comparison of total area under the chromatogram of the sample with total area of a standard technical chlordane be the method of quantitation. Only peaks which are common to both standard and sample have any significance in this type of calculation.


1998 ◽  
Vol 61 (4) ◽  
pp. 449-453 ◽  
Author(s):  
Valérie Magne ◽  
Mohamed Mathlouthi ◽  
Bertrand Robilland

2010 ◽  
Vol 48 (7) ◽  
pp. 553-558 ◽  
Author(s):  
H. Zhu ◽  
H. Chen ◽  
Y. Zhong ◽  
D. Ren ◽  
Y. Qian ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document