Characterization and assessment of a large-scale domestic advanced wastewater treatment plant in Turkey

2011 ◽  
Vol 184 (9) ◽  
pp. 5275-5281 ◽  
Author(s):  
Oktay Özkan ◽  
Merve Oğuz ◽  
Özgür Özdemir
2017 ◽  
Vol 77 (2) ◽  
pp. 337-345 ◽  
Author(s):  
I. Brückner ◽  
K. Kirchner ◽  
Y. Müller ◽  
S. Schiwy ◽  
K. Klaer ◽  
...  

Abstract The project DemO3AC (demonstration of large-scale wastewater ozonation at the Aachen-Soers wastewater treatment plant, Germany) of the Eifel-Rur Waterboard contains the construction of a large-scale ozonation plant for advanced treatment of the entire 25 million m³/yr of wastewater passing through its largest wastewater treatment plant (WWTP). In dry periods, up to 70% of the receiving water consists of treated wastewater. Thus, it is expected that effects of ozonation on downstream water biocoenosis will become observable. Extensive monitoring of receiving water and the WWTP shows a severe pollution with micropollutants (already prior to WWTP inlet). (Eco-)Toxicological investigations showed increased toxicity at the inlet of the WWTP for all assays. However, endocrine-disrupting potential was also present at other sampling points at the WWTP and in the river and could not be eliminated sufficiently by the WWTP. Total cell counts at the WWTP are slightly below average. Investigations of antibiotic resistances show no increase after the WWTP outlet in the river. However, cells carrying antibiotic-resistant genes seem to be more stress resistant in general. Comparing investigations after implementation of ozonation should lead to an approximation of the correlation between micropollutants and water quality/biocoenosis and the effects that ozonation has on this matter.


2012 ◽  
Vol 2012 (15) ◽  
pp. 1959-1967
Author(s):  
Ahmed Al-Omari ◽  
Mofei Han ◽  
Bernhard Wett ◽  
Norman Dockett ◽  
Beverley Stinson ◽  
...  

2009 ◽  
Vol 2009 (3) ◽  
pp. 887-898 ◽  
Author(s):  
Christopher A. Wilson ◽  
John T. Novak ◽  
Sudhir N. Murthy ◽  
Walter F. Bailey

Author(s):  
Ragessi I. Matias ◽  
Leyria Rainieri Gianina ◽  
Ganancias Facundo ◽  
García C. Marcelo ◽  
Di Buo Melina ◽  
...  

Abstract The Costa Azul wastewater treatment plant is situated in Carlos Paz city (Córdoba, Argentina). The treated water is discharged to the San Roque reservoir, which is the source of water for the city of Córdoba and surrounding towns. Consequently, it is of great importance to evaluate the potential impact on the water quality reservoir for the preservation of public health. Currently, the WWTP lacks an accurate flow monitoring system at the last treatment: disinfection. This problem led to the development of a methodology in which experimental in-situ work and computational fluid dynamics (CFD) were applied, in a combined way, to calibrate the flow measurement system. First, Large Scale Particle Image Velocimetry (LS-PIV) was applied. The results made it possible to obtain characteristic parameters of the average flow: cross-sectional velocity profiles, recirculation and flow stagnation zones, flow discharge and characteristic parameters of the contact chamber. Second, numerical models, based on the Reynolds-average Navier–Stokes equations with the k–ε turbulent closure model were used. Based on the simulations results, it was possible to calibrate the discharge equation for a rectangular weir, and elaborate recommendations to improve the discharge measurement system and hydraulics in the area of the contact chamber curves.


Author(s):  
A. Bernardelli ◽  
S. Marsili-Libelli ◽  
A. Manzini ◽  
S. Stancari ◽  
G. Tardini ◽  
...  

Abstract Two separate goals should be jointly pursued in wastewater treatment: nutrient removal and energy conservation. An efficient controller performance should cope with process uncertainties, seasonal variations and process nonlinearities. This paper describes the design and testing of a model predictive controller (MPC) based on neuro-fuzzy techniques that is capable of estimating the main process variables and providing the right amount of aeration to achieve an efficient and economical operation. This algorithm has been field tested on a large-scale municipal wastewater treatment plant of about 500,000 PE, with encouraging results in terms of better effluent quality and energy savings.


2010 ◽  
Vol 2010 (16) ◽  
pp. 1200-1228
Author(s):  
Christian Davies-Venn ◽  
Laetitia Mulamula ◽  
Dennis Greene ◽  
Salil Kharkar ◽  
Aklile Tesfaye ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document