scholarly journals Special Issue in Fire Hazards in Energy Systems

2016 ◽  
Vol 52 (2) ◽  
pp. 285-287
Author(s):  
Georgios Boustras ◽  
Guillermo Rein
2021 ◽  
Vol 51 (4) ◽  
pp. 2036-2040
Author(s):  
Ratnesh Kumar ◽  
Thomas I. Strasser ◽  
Geert Deconinck ◽  
Chun Sing Lai ◽  
Loi Lei Lai

2012 ◽  
Vol 468-471 ◽  
pp. 1753-1757
Author(s):  
Yang Wei Shao ◽  
Shih Feng Kao ◽  
Neng Chun Yu ◽  
Yu Shiang Wu ◽  
Chi Jan Huang ◽  
...  

Although meeting the regulations of the time, early buildings are prone to fire hazards, such as damages to the fire zones, changes of floor entrances and exits, locked emergency exit doors, blocking of entrances and exits by vehicles, increased fire sources, dense population in the buildings, due to insufficient professional knowledge and technology in fire prevention. Once a fire occurs, it can result in major casualties, serious loss of social costs, as well as environmental and social issues. This study investigated 17 major fire cases occurring in residential-commercial composite buildings in the last 20 years in Taiwan. The fire hazard factors were determined based on expert review. The findings can serve as a reference for fire agencies in promoting fire prevention.


JOURNAL ASRO ◽  
2021 ◽  
Vol 12 (02) ◽  
pp. 10
Author(s):  
Dodiek Alfianzi ◽  
Ikhwan Syahtaria ◽  
Udisubakti Cipto Mulyono ◽  
I Made Jiwa Astika

Designing a fire prevention inspection system in buildings is very necessary, to determine the level of reliability. The fire prevention management system uses the following criteria: precautionary measures and preventive supervision against fire hazards. The assessment of the system design is carried out by means of a questionnaire for respondents who understand / are experts in fire problems, and the application of the system design uses direct surveys and questionnaires to the building manager. The assessment is carried out at the smallest level. Analysis of the building reliability inspection system in fire prevention using the Analytical Hierarchy Process (AHP) method, the criteria used are: prevention, limitation and extinguishing against fire. The fire prevention management system uses the following criteria: precautionary measures and preventive supervision against fire hazards. The results of the reliability inspection of the Ki Hadjar Dewantara Mako Kodiklatal building in Surabaya with a value of 94.06% indicated that the reliability system was in the "Less Reliable" category for fire hazard prevention.   Keywords: Inspection, fire prevention, reliability.


2019 ◽  
Vol 21 (4) ◽  
pp. 1778-1780
Author(s):  
Jian Chen ◽  
Mohamed Becherif ◽  
Haitham S. Ramadan

Sign in / Sign up

Export Citation Format

Share Document