scholarly journals Discussion of “Strength and Consolidation Characteristics for Cement Stabilized Cohesive Soil Considering Consistency Index” by Ahmed F. Zidan, published in Geotechnical and Geological Engineering, https://doi.org/10.1007/s10706-020-01367-6

Author(s):  
Brendan C. O’Kelly
2015 ◽  
Vol 37 (4) ◽  
pp. 37-46
Author(s):  
Piotr Pezowicz ◽  
Krystyna Choma-Moryl

Abstract Results of investigations of shearing resistance and compressibility of fine-grained cohesive soil from the southern part of the wielkopolskie voivodeship in relation to the increasing moisture content are presented. The analysis of two series of samples, using soil paste for the consistency index of 0.9 and 0.4–0.3 was carried out. The results imply that the increasing moisture content causes a decrease in the angle of shearing resistance and cohesion and is also reflected in the higher compressibility of the soil. It was observed that regardless of the soil consistency, the angle of shearing resistance decreases and the cohesion value and the oedometric modulus of primary (consolidation) and secondary compressibility grows with the increase in the clay fraction.


2019 ◽  
Vol 12 ◽  
pp. 141-150
Author(s):  
I.P. Bashilov ◽  
◽  
A.A. Vereshchagin ◽  
L.S. Zagorskiy ◽  
D.L. Zagorskiy ◽  
...  

2019 ◽  
Vol 92 ◽  
pp. 01004
Author(s):  
Christopher Ibeh ◽  
Matteo Pedrotti ◽  
Alessandro Tarantino ◽  
Rebecca Lunn

The quality and reliability of cohesive soil laboratory test data can be significantlyaffected by sample disturbance during sampling or sample preparation. Sample disturbance may affect key design and modelling parameters such as stiffness, preconsolidation stress, compressibility and undrained shear strength, and ultimately determine particle mobilization and shear plane development. The use of X-ray computed tomography (X-CT) in the study of soil is restricted by the inverse relationship of specimen size and obtainable image resolution. This has led to the testing of miniature specimen sizes which are far less than conventional laboratory sample size in a bid to obtain high resolution images and detailed particle-scale soil properties; however, these miniature soil specimens are more prone to sample disturbance. In this work 2% muscovite was mixed with speswhite kaolin clay as a strain marker for use in X-CT. The clay soil sample was prepared from slurry and either consolidated using an oedometer or a gypsum mould. Specimens obtained from a 7 mm tube sampler were compared to lathe trimmed specimens with a diameter (Ø) of 7 mm. Results from X-CT imaging were used to study the influence of sampler type on specimen disturbance, by analysing the muscovite particle orientation of the obtained 3D images. The results show that; for samples subjected to large consolidation stress (>200kpa) lathe trimmed specimens may be subject to lesser disturbance compared to tube sampled specimens.


Sign in / Sign up

Export Citation Format

Share Document