The Influence of Audible Alarm Loudness and Type on Clinical Multitasking

2021 ◽  
Vol 46 (1) ◽  
Author(s):  
Alexandra L. Bruder ◽  
Clayton D. Rothwell ◽  
Laura I. Fuhr ◽  
Matthew S. Shotwell ◽  
Judy Reed Edworthy ◽  
...  
Keyword(s):  
Author(s):  
Judy Reed Edworthy ◽  
Richard R. McNeer ◽  
Christopher L. Bennett ◽  
Roman Dudaryk ◽  
Siné J. P. McDougall ◽  
...  

The reserved set of audible alarm signals embodied within the global medical device safety standard, IEC 60601-1-8, is known to be problematic and in need of updating. The current alarm signals are not only suboptimal, but there is also little evidence beyond learnability (which is known to be poor) that demonstrates their performance in realistic and representative clinical environments. In this article, we describe the process of first designing and then testing potential replacement audible alarm signals for IEC 60601-1-8, starting with the design of several sets of candidate sounds and initial tests on learnability and localizability, followed by testing in simulated clinical environments. We demonstrate that in all tests, the alarm signals selected for further development significantly outperform the current alarm signals. We describe the process of collecting considerably more data on the performance of the new sounds than exists for the current sounds, which ultimately will be of use to end users. We also reflect on the process and practice of working with the relevant committees and other practical issues beyond the science, which also need constant attention if the alarms we have developed are to be included successfully in an updated version of the standard.


1996 ◽  
Vol 24 (6) ◽  
pp. 682-684 ◽  
Author(s):  
R. W. Morris ◽  
S. R. Montano

Objective To measure and compare the response times to audibly or visually presented alarms in the operating theatre. Methods The time taken by anaesthetists to cancel randomly generated visual and audible false alarms was measured during maintenance of routine anaesthesia. Alarms were generated and times recorded by a laptop computer on the anaesthetic machine. The visual signal was a 15mm diameter red light positioned next to the physiological monitor mounted on top of the machine. The audible alarm was a Sonalert® buzzer of the type incorporated into many medical devices. Results Nineteen anaesthetists provided a total of seventy-two hours of data (887 alarm events). The response times to visual alarms was significantly longer than to audible alarms (P=0.001 Mann Whitney U test). Conclusions The ability of anaesthetists to appreciate changes in patient physiology may be limited by delays in noticing information presented by monitors. The rapid response to the vast majority of alarms indicates a high level of vigilance among the anaesthetists studied. However, this study suggests that it is safer to rely on audible rather than visual alarms when time-critical information such as oxygenation, heart beat and ventilator disconnection is concerned. Visual alarms would appear to be more appropriate for conveying less urgent information.


2008 ◽  
Vol 86 ◽  
pp. 0-0
Author(s):  
P KOTHY ◽  
G HOLLO
Keyword(s):  

2003 ◽  
Vol 113 (4) ◽  
pp. 1791
Author(s):  
Mead C. Killion
Keyword(s):  

Hemodialysis is a life-preserving treatment for a number of patients with kidney failure. Hemodialysis is usually done three times per week for about four hours at a time. During the hemodialysis procedure, the patient usually suffering from many inconvenient, fatigue, stress and disturbance in the work of the heart and cardiovascular system are the most common signs. This paper provides a solution to reduce the previous problems by designing a wearable artificial kidney (WAK) taking in consideration minimization the size of the dialysis machine. The WAK system consists of two circuits: blood circuit and dialysate circuit. The blood from the patient is filtered in the dialyzer before returning back to the patient. Several parameters using an advanced microcontroller and array of sensors are considered. WAK equipped with visible and audible alarm system to aware the patients if there is any problem.