Measurement and covariance analysis of 232Th(n, 2n)231Th reaction cross sections at the effective neutron energies of 8.97 and 16.52 MeV

2018 ◽  
Vol 318 (3) ◽  
pp. 1893-1900 ◽  
Author(s):  
Meghna Karkera ◽  
Haladhara Naik ◽  
Sripathi Punchithaya ◽  
Manjunatha Prasad ◽  
Santhi Sheela Yeraguntla ◽  
...  
2020 ◽  
Vol 325 (3) ◽  
pp. 831-840
Author(s):  
Sangeetha Prasanna Ram ◽  
Jayalekshmi Nair ◽  
Saraswatula Venkata Suryanarayana ◽  
Laxman Singh Danu ◽  
Saroj Bishnoi ◽  
...  

2020 ◽  
Vol 326 (1) ◽  
pp. 637-645
Author(s):  
A. M. Sunitha ◽  
Kamsali Nagaraja ◽  
H. B. Sachhidananda ◽  
S. V. Suryanarayana ◽  
B. Rudraswamy ◽  
...  

2020 ◽  
Vol 325 (3) ◽  
pp. 863-868
Author(s):  
Imran Pasha ◽  
Rudraswamy Basavanna ◽  
Santhi Sheela Yerranguntla ◽  
Saraswatula Venkata Suryanarayana ◽  
Rebecca Pachuau ◽  
...  

2018 ◽  
Vol 319 (3) ◽  
pp. 695-701
Author(s):  
B. Lawriniang ◽  
R. Ghosh ◽  
S. Badwar ◽  
Santhi Sheela Yerraguntla ◽  
B. Jyrwa ◽  
...  

2017 ◽  
Vol 314 (1) ◽  
pp. 457-465 ◽  
Author(s):  
Santhi Sheela Yerraguntla ◽  
Haladhara Naik ◽  
Manjunatha Prasad Karantha ◽  
Srinivasan Ganesan ◽  
Saraswatula Venkata Suryanarayana ◽  
...  

2018 ◽  
Vol 106 (11) ◽  
pp. 877-884 ◽  
Author(s):  
Santhi Sheela Yerraguntla ◽  
Haladhara Naik ◽  
Manjunatha Karantha ◽  
Srinivasan Ganesan ◽  
Suryanarayana Venkata Saraswatula ◽  
...  

Abstract The 59Co(n, 2n)58Co reaction cross sections relative to the cross sections of the 115In(n, n′)115mIn reaction have been measured at the effective neutron energies of 11.98 and 15.75 MeV by using activation and off-line γ-ray spectrometric technique. Neutron beam used in the present experiment was generated from the 7Li(p, n)7Be reaction with the proton energies of 14 and 18 MeV at the 14UD BARC-TIFR Pelletron facility, Mumbai. We also present the covariance information by taking into account the sources of error and the correlations between the attributes influencing the measurements. The 59Co(n, 2n)58Co reaction cross sections from the present work are then compared with the values from different evaluated nuclear data libraries. The micro-correlation technique suggested by Smith was modified to generate the covariance matrix for the measurements of reaction cross sections as the efficiencies of detector for the sample and monitor are correlated.


2019 ◽  
Vol 322 (3) ◽  
pp. 2057-2064 ◽  
Author(s):  
Imran Pasha ◽  
Rudraswamy Basavanna ◽  
Santhi Sheela Yerranguntla ◽  
Saraswatula Venkata Suryanarayana ◽  
Haladhara Naik ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document