Effectiveness of the intraoperative magnetic resonance imaging during endoscopic endonasal approach for acromegaly

Pituitary ◽  
2021 ◽  
Author(s):  
Toshihiro Ogiwara ◽  
Takahide Hori ◽  
Yu Fujii ◽  
Takuya Nakamura ◽  
Yota Suzuki ◽  
...  
2022 ◽  
Vol 11 ◽  
Author(s):  
Beste Gulsuna ◽  
Burak Karaaslan ◽  
Memduh Kaymaz ◽  
Hakan Emmez ◽  
Emetullah Cindil ◽  
...  

BackgroundCranial base chordomas are typically indolent and usually appear as encapsulated tumors. They slowly grow by infiltrating the bone, along with the lines of least resistance. Due to its relationship with important neurovascular structures, skull base chordoma surgery is challenging.ObjectiveThe usefulness of intraoperative magnetic resonance imaging (IO-MRI) in achieving the goal of surgery, is evaluated in this study.MethodsBetween March 2018 and March 2020, 42 patients were operated on for resection of skull base chordomas in our institution. All of them were operated on under IO-MRI. Patients were analyzed retrospectively for identifying common residue locations, complications and early post-operative outcomes.ResultsIn 22 patients (52,4%) gross total resection was achieved according to the final IO-MRI. In 20 patients (47,6%) complete tumor removal was not possible because of extension to the petrous bone (8 patients), pontocerebellar angle (6 patients), prepontine cistern (4 patients), temporobasal (1 patient), cervical axis (1 patient). In 13 patients, the surgery was continued after the first IO-MRI control was performed, which showed a resectable residual tumor. 7 of these patients achieved total resection according to the second IO-MRI, in the other 6 patients all efforts were made to ensure maximal resection of the tumor as much as possible without morbidity. Repeated IO-MRI helped achieve gross total resection in 7 patients (53.8%).ConclusionsOur study proves that the use of IO-MRI is a safe method that provides the opportunity to show the degree of resection in skull base chordomas and to evaluate the volume and location of the residual tumor intraoperatively. Hence IO-MRI can improve the life expectancy of patients because it provides an opportunity for both gross total resection and maximal safe resection in cases where total resection is not possible.


2006 ◽  
Vol 58 (suppl_1) ◽  
pp. ONS-44-ONS-51 ◽  
Author(s):  
Theodore H. Schwartz ◽  
Phillip E. Stieg ◽  
Vijay K. Anand

Abstract OBJECTIVE: The two most recent significant advances in pituitary surgery have been the endonasal endoscopic approach and intraoperative magnetic resonance imaging (IMRI). Each provides improved visualization of intra- and parasellar anatomy with the goal of attaining a complete resection. The combination of the two techniques has not been previously reported in the literature. METHODS: We performed endoscopic, endonasal resection of pituitary macroadenomas in 15 patients using the Polestar N-10 (0.12T) IMRI (Odin Medical Technologies, Inc., Newton, MA). Eleven patients had nonfunctioning tumors, three had acromegaly, and one had a medication-resistant prolactinoma. The effect of the magnetic field on the cathode ray tube screen and the image quality of the IMRI images were assessed. The presence of residual tumor on IMRI was noted and then re-examined with the endoscope. RESULTS: Although the Polestar N-10 is a low Tesla magnet, the IMRI caused significant distortion of the cathode ray tube screen regardless of the viewing angle. This was overcome with the use of a wall-mounted plasma screen. IMRI images were obtained in all cases and were of sufficiently high quality to demonstrate adequate decompression of the optic chiasm and the removal of all suprasellar tumor. In three cases, residual tumor was found with IMRI that was resected endoscopically before the completion of surgery. In four other cases, potential residual tumor was examined endoscopically and found to be normal postoperative change. In eight cases no residual intrasellar tumor was seen on the IMRI. Preresection visual deficits improved in all cases and the insulin-like growth factor levels normalized in two of three cases. There were no delayed cerebrospinal fluid leaks. CONCLUSION: Combining intraoperative endoscopy and IMRI is feasible and distortion of the cathode ray tube screen can be overcome with the use of either a plasma or liquid crystal display screen. Each technology provides complementary information, which can assist the surgeon in safely maximizing the extent of resection. In this small series using a low-field magnet, rates of residual tumor following endoscopic trans-sphenoidal surgery were less than have been reported following microscope-based transsphenoidal surgery.


Sign in / Sign up

Export Citation Format

Share Document