Response characteristics of lead-selective membrane sensors based on a newly synthesized quinoxaline derivatives as neutral carrier ionophores

Ionics ◽  
2017 ◽  
Vol 23 (12) ◽  
pp. 3497-3506 ◽  
Author(s):  
Ayman H. Kamel ◽  
Abeer M. El-Naggar ◽  
Amina A. A. Argig
Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6375
Author(s):  
Junghwan Kim ◽  
Dae Hee Kim ◽  
Jin Cheol Yang ◽  
Jae Sang Kim ◽  
Ji Ha Lee ◽  
...  

A beryllium(II)-ion-selective poly(ethylenedioxythiophene) (PEDOT) solid contact electrode comprising 9,10-dinitrobenzo-9-crown-3-ether was successfully developed. The all-solid-state contact electrode, with an oxygen-containing cation-sensing membrane combined with an electropolymerized PEDOT layer, exhibited the best response characteristics. The performance of the constructed electrode was evaluated and optimized using potentiometry, conductance measurements, constant-current chronopotentiometry, and electrochemical impedance spectroscopy (EIS). Under optimized conditions, which were found for an ion-selective membrane (ISM) composition of 3% ionophore, 30% polyvinylchloride (PVC), 64% o-nitro phenyl octyl ether (o-NPOE), and 3% sodium tetraphenylborate (NaTPB), the fabricated electrode exhibited a good performance over a wide concentration range (10−2.5–10−7.0 M) and a wide pH range of 2.0–9.0, with a Nernstian slope of 29.5 mV/D for the beryllium (II) ion and a detection limit as low as 10−7.0 M. The developed electrode shows good selectivity for the beryllium(II) ion over alkali, alkaline earth, transition, and heavy metal ions.


Desalination ◽  
2005 ◽  
Vol 180 (1-3) ◽  
pp. 207-215 ◽  
Author(s):  
Ya-Qing Chai ◽  
Jian-Yuan Dai ◽  
Ruo Yuan ◽  
Xia Zhong ◽  
Yan Liu ◽  
...  

1999 ◽  
Vol 364 (8) ◽  
pp. 690-693 ◽  
Author(s):  
M. K. Amini ◽  
M. Mazloum ◽  
A. A. Ensafi

1984 ◽  
Vol 49 (10) ◽  
pp. 2371-2375 ◽  
Author(s):  
Olen Ryba ◽  
Jaromír Petránek

Shifts of the potentials of a calcium ion-selective electrode based on the complex of 7,19-dibenzyl-2,2,3,3-tetramethyl-7,19-diaza-1,4,10,13,16-pentaoxacycloheneicosane-6,20-dione with calcium tetra(4-chlorophenyl)borate in various membrane solvents caused by changes in hydrodynamic conditions in the measured solution were examined. The use of 2-fluoro-2'-nitrodiphenyl ether as a membrane solvent combined with substitution of benzyl groups with octyl ones in the neutral carrier eliminates this unfavourable phenomenon while preserving the selectivity parameters of the electrode.


2005 ◽  
Vol 38 (1) ◽  
pp. 45-56 ◽  
Author(s):  
Yaqing Chai ◽  
Ruo Yuan ◽  
Jianyun Dai ◽  
Lan Xu ◽  
Guofeng Gui ◽  
...  

2005 ◽  
Vol 107 (2) ◽  
pp. 756-761 ◽  
Author(s):  
H. Aghaie ◽  
M. Giahi ◽  
M. Monajjemi ◽  
M. Arvand ◽  
G.H. Nafissi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document