Power flow calculation method of large shipboard power system

2010 ◽  
Vol 9 (1) ◽  
pp. 93-98
Author(s):  
Hai Lan ◽  
Jiu-fang Li ◽  
Dian-hua Zhang
2020 ◽  
Vol 10 (3) ◽  
pp. 1034
Author(s):  
Insu Kim

Dynamic and static reactive power resources have become an important means of maintaining the stability and reliability of power system networks. For example, if reactive power is not appropriately compensated for in transmission and distribution systems, the receiving end voltage may fall dramatically, or the load voltage may increase to a level that trips protection devices. However, none of the previous optimal power-flow studies for reactive power generation (RPG) units have optimized the location and capacity of RPG units by the bus impedance matrix power-flow calculation method. Thus, this study proposes a genetic algorithm that optimizes the location and capacity of RPG units, which is implemented by MATLAB. In addition, this study enhances the algorithm by incorporating bus impedance power-flow calculation method into the algorithm. The proposed hybrid algorithm is shown to be valid when applied to well-known IEEE test systems.


2017 ◽  
Vol 2017 (14) ◽  
pp. 2615-2621
Author(s):  
Jinquan Wang ◽  
Jun Yan ◽  
Ye Xu ◽  
Kefeng Huang

2013 ◽  
Vol 385-386 ◽  
pp. 668-674
Author(s):  
Jia Yang ◽  
Hai Bao ◽  
Ling Wang ◽  
Gang Liu

Steady-state power flow calculation belongs to power system steady-state analysis, and the data used in calculation should be steady-state data. However, the existing SCADA system hasnt distinguished the transient data from the steady-state data. The real-time measured data reflect the dynamic electric power system. It is the right reason for not all of the real-time measured power can be used for power flow calculation. In another word, it causes the matching problem between measured data and power flow calculations. Based on the current situation of information collection system, the characteristics of the measured data had been analyzed in this paper. And an effective acquisition method for steady-state measured data is proposed on the theoretical basis of the law of large numbers. It uses the average value of the measured data that in the same load state to approximate the steady-state true value in one period. And the steady-state data can be used in power flow calculation. The simulation results show that the method proposed in this paper ensures the accuracy and reliability of power flow calculation.


Sign in / Sign up

Export Citation Format

Share Document