Evaluating response modification factor (R) of reinforced concrete frames with chevron brace equipped with steel slit damper

2016 ◽  
Vol 21 (4) ◽  
pp. 1417-1423 ◽  
Author(s):  
A. Keykhosravi ◽  
R. Aghayari
Author(s):  
Amira Elyamany Mohamed ◽  
Walid A Attia ◽  
Wael M. El-Degwy

Response modification factor is an essential factor in seismic analysis to provide economic design of reinforced concrete structures. Base shear force is divided by the response modification factor to consider the ability of the structure to dissipate energy through plastic hinges. The current study investigates the effects of changing some parameters on response modification factor (R-factor). Four groups of reinforced concrete frames were studied with different number of bays, number of stories, load pattern, and fundamental period of vibration. All reinforced concrete frames were analyzed using SAP 2000 then the straining actions results were used at specific excel sheets which are developed to design reinforced concrete members according to the Egyptian code of practice ECP-203 and ECP-201. Frames were analyzed by nonlinear static analysis (pushover analysis) using SAP2000. A sum of thirty two systems of frames was analyzed. According to the results, every frame has its unique value of R-factor. Accordingly, many parameters should be mentioned and considered at code to simulate the actual value of R-factor for each frame. Response modification factor is affected by many factors like stiffness, fundamental period of vibration, number of bays, frame height, geometry of the structure, etc. The given values of R-factor at ECP-201 can be considered conservative; as the accurate values of R-factor is higher than the given values.


2019 ◽  
Vol 3 (Special Issue on First SACEE'19) ◽  
pp. 233-240
Author(s):  
Junaid Akbar ◽  
Naveed Ahmad ◽  
Bashir Alam

Shaking table tests were performed on five one-third reduced scale two storey reinforced concrete (RC) moment resisting frames having construction defects (using low strength concrete without confining ties in beam-column joints, larger tie spacing, and reduced longitudinal and transverse reinforcements). The deficient frames were observed to have severe joint damageability, resulting in joint panel cover spalling and core concrete crushing. Haunch retrofitting technique was adopted to upgrade the seismic behaviour of deficient RC frames. Additional four deficient RC frames were built and retrofitted with steel haunch; both axially stiffer and deformable with energy dissipation, fixed to the beam-column connections to reduce shear demand on joint panels. The as-built and retrofitted frame seismic response modification factor (R) was calculated and compared to evaluate the viability of the haunch retrofitting technique. The haunch retrofitting technique increased the lateral stiffness and strength of the structure, resulting in the increase of structure overstrength. The retrofitting increased R factor by sixty percent to one hundred percent. The presented results indicate that the technique can significantly enhance the seismic performance of deficient RC frames, particularly against the frequent and rare earthquake events.


2020 ◽  
Vol 87 (1) ◽  
pp. 92-100 ◽  
Author(s):  
N.V. FEDOROVA ◽  
◽  
FAN DINH GUOK ◽  
NGUYEN THI CHANG ◽  
◽  
...  

Author(s):  
Seung-Jae Lee ◽  
Tae-Sung Eom ◽  
Eunjong Yu

AbstractThis study analytically investigated the behavior of reinforced concrete frames with masonry infills. For the analysis, VecTor2, a nonlinear finite element analysis program that implements the Modified Compression Field Theory and Disturbed Stress Field Model, was used. To account for the slip behavior at the mortar joints in the masonry element, the hyperbolic Mohr–Coulomb yield criterion, defined as a function of cohesion and friction angle, was used. The analysis results showed that the lateral resistance and failure mode of the infilled frames were significantly affected by the thickness of the masonry infill, cohesion on the mortar joint–brick interface, and poor mortar filling (or gap) on the masonry boundary under the beam. Diagonal strut actions developed along two or three load paths on the mortar infill, including the backstay actions near the tension column and push-down actions near the compression columns. Such backstay and push-down actions increased the axial and shear forces of columns, and ultimately affect the strength, ductility, and failure mode of the infilled frames.


2019 ◽  
Vol 289 ◽  
pp. 04004
Author(s):  
George Hopartean ◽  
Ted Donchev ◽  
Diana Petkova ◽  
Costas Georgopoulos ◽  
Mukesh Limbachiya ◽  
...  

Fibre reinforced polymers (FRP) have been used as strengthening for existing RC structures for many decades. Lately, there has been a lot of interest in using FRP as internal reinforcement in beams, slabs and columns. One potential area of application could be reinforced concrete frames internally reinforced with GFRP bars. With limited research in this direction, the objective of this publication is to assess the behaviour of glass FRP (GFRP) reinforced concrete frames under reversed cyclic lateral in plane loading and to analyse the seismic performances of such elements. For the purpose of this paper, experimental testing of two 1/3 scaled down frames is conducted in displacement-controlled mode with the loading history according to ACI 374.1-05. The control sample is reinforced with conventional steel reinforcement and the results obtained are compared with the sample reinforced with GFRP bars. In summary, observations on the sample behaviour at specified drift ratio such as load-displacement behaviour, envelope curves and energy dissipation are presented.


Sign in / Sign up

Export Citation Format

Share Document