Experimental and Numerical Investigation of the Effect of a New Type of Channel Stiffener on the Seismic Behavior of Steel Shear Wall Incorporated Moment Resisting Frames

2019 ◽  
Vol 19 (6) ◽  
pp. 1785-1800
Author(s):  
M. TahamouliRoudsari ◽  
M. Torkaman ◽  
L. Shirkhani ◽  
M. R. Nasimi ◽  
M. Mirzaei
2014 ◽  
Vol 638-640 ◽  
pp. 1932-1936 ◽  
Author(s):  
Jian Hua Shao ◽  
Qun Wu

The seismic behavior factor of moment resisting steel frame-steel plate shear wall under two different horizontal loading patterns was investigated according to the maximum inter-story drift ratio reaching 1/50. It could be achieved with the same calculated standard as the foreign codes and the determined behavior factor was compared with foreign research results. The method using the software SAP2000 to calculate seismic behavior factor according to the maximum inter-story drift ratio reaching 1/50 was presented and the specific example was used to elaborate the operating process. The seismic behavior factor R, the overstrength factor RΩ and the ductility reduction factor Rμ of 10-storey 3-span steel frame-steel plate shear wall under the inverted triangle load are respectively 6.07, 2.96 and 2.05. while they are respectively 7.2, 3.37 and 2.13 under the uniform load. Finally, it can be concluded that the economic and reasonable design goals are achieved for this structure.


2021 ◽  
Vol 186 ◽  
pp. 106910
Author(s):  
Abed Rigi ◽  
Behtash JavidSharifi ◽  
Mohammad Ali Hadianfard ◽  
T.Y. Yang

2019 ◽  
Vol 15 (8) ◽  
pp. 155014771985756 ◽  
Author(s):  
Mehdi Firoozbakht ◽  
Hamidreza Vosoughifar ◽  
Alireza Ghari Ghoran

The coverage intensity of sensors is the most important issue on structural health monitoring technique. The geometric configuration of sensors must be optimized based on coverage intensity with proper objectives. In this article, a novel algorithm for optimal sensor placement in various steel frames was evaluated. These frames including moment-resisting frame, moment-resisting frame with base isolation, and moment-resisting frame with base isolation with steel shear wall were selected for case studies. This approach was proposed based on combination of common optimal sensor placement algorithm and nonlinear time history analysis. A new method called transformed time history to frequency domain approach was evaluated to transform nonlinear time history analysis results to frequency domain and then the effective frequencies according the maximum range of Fourier amplitude were selected. The modified type of modal assurance criterion values can be achieved from modal assurance criterion with the exact seismic displacement. All of novel optimal sensor placement processes were done through FEM-MAC-TTFD code modeled and developed in MATLAB by authors of this article. The results show that there is good relative correlation between the sensors number and coverage intensity obtained with modal and modified modal assurance criterion approaches for moment-resisting frame system, but for integrated frame such as moment-resisting frame with base isolation and moment-resisting frame with base isolation with steel shear wall, the modified modal assurance criterion approach is better approach. There is no significant difference between coverage intensity of sensors for top joints between modal assurance criterion and modified modal assurance criterion approaches for moment-resisting frame, moment-resisting frame with base isolation, and moment-resisting frame with base isolation with steel shear wall systems ( R2 = 0.994, 0.986, and 0.724, respectively). It was found that if reference point is located in center of frame, there is significant difference between modal assurance criterion and modified modal assurance criterion approaches, and modified modal assurance criterion generated slightly better results.


2017 ◽  
Vol 11 (1) ◽  
pp. 255-273 ◽  
Author(s):  
Jun He ◽  
Jing Li ◽  
Zhuoyang Xin ◽  
Weian Jiang

Background and Methods: This paper illustrates a research on the behavior of the composite timber panels used in a new-type cold-formed steel shear wall, when subjected to monotonic and reversed cyclic in-plane loading. The framing members of this new-type cold-formed steel shear wall are made of cold-formed steels. The inner timber frameworks, sheathed with veneer plywood, form the composite timber panels. Objective: In order to improve the lateral performance of the new-type cold-formed steel shear wall, two different optimized composite timber panels were proposed and tested, namely, increasing the thickness of the sheathings and the addition of steel X-bracings. The main objective of the study is to determine the quantification of the improvement in lateral performance of these two optimized composite timber panels. Results and Conclusion: Observed failure modes, structural performance parameters and the data of the strain gauges were given for each specimen, which indicates two optimized panels both have better lateral performance. But larger deformation and damage of the sheathings happened on the panels with steel X-bracings, so the panels with thick sheathings are more suitable and practical for normal use.


Sign in / Sign up

Export Citation Format

Share Document