Analysis of biological clogging potential in a simulated compacted clay liner subjected to high-strength leachate infiltration

2017 ◽  
Vol 15 (5) ◽  
pp. 1029-1038 ◽  
Author(s):  
E. Safari ◽  
R. Valizadeh
2021 ◽  
Vol 13 (13) ◽  
pp. 7301
Author(s):  
Marcin K. Widomski ◽  
Anna Musz-Pomorska ◽  
Wojciech Franus

This paper presents research considering hydraulic as well as swelling and shrinkage characteristics of potential recycled fine particle materials for compacted clay liner for sustainable landfills. Five locally available clay soils mixed with 10% (by mass) of NaP1 recycled zeolite were tested. The performed analysis was based on determined plasticity, cation exchange capacity, coefficient of saturated hydraulic conductivity after compaction, several shrinkage and swelling characteristics as well as, finally, saturated hydraulic conductivity after three cycles of drying and rewetting of tested specimens and the reference samples. The obtained results showed that addition of zeolite to clay soils allowed reduction in their saturated hydraulic conductivity to meet the required threshold (≤1 × 10−9 m/s) of sealing capabilities for compacted clay liner. On the other hand, an increase in plasticity, swelling, and in several cases in shrinkage, of the clay–zeolite mixture was observed. Finally, none of the tested mixtures was able to sustain its sealing capabilities after three cycles of drying and rewetting. Thus, the studied clayey soils mixed with sustainable recycled zeolite were assessed as promising materials for compacted liner construction. However, the liner should be operated carefully to avoid extensive dissication and cracking.


1989 ◽  
Vol 16 (4) ◽  
pp. 552-559 ◽  
Author(s):  
Peter A. L. Richards ◽  
Christopher D. Thompson

The Provisional Certificate of Approval to construct a sanitary landfill for municipal waste in an old gravel pit in the Oak Ridges Moraine north of Toronto, Ontario, required that a 1.2 m thick compacted clay liner with a permeability of less than 10−8 cm/s should be placed beneath any refuse. Preliminary testing indicated that the native tills from the immediate vicinity were marginally capable of providing such a liner, as long as they were carefully selected and compacted at moisture contents just above optimum values. However, it was clear that the variability of material and (or) testing was such that some liner samples could have permeabilities greater than 10−8 cm/s. Additionally, there was concern that the sampling and testing procedures could affect the results. This paper details the trials which were carried out at the beginning of construction to establish acceptable sampling and testing techniques.These were finally determined to consist of carefully obtained Shelby tube samples, the permeability of which was tested at representative pressures in triaxial cells. The paper then presents the statistical analyses which were used to verify that the overall permeability of the liner is less than 10−8 cm/s. It also outlines other testing and instrumentation which has been undertaken to verify the liner permeability and integrity. It is concluded that, to date, the permeability testing and protocol are suitable control procedures to verify compliance with the condition of the Provisional Certificate of Approval that a liner permeability of 10−8 cm/s be achieved. Key words: clay liner, permeability, protocol, quality control, sanitary landfill, sampling, statistical analysis, testing.


Author(s):  
Sanjay Kumar Shukla ◽  
Pavan Chauhan ◽  
M. Muthukumar ◽  
Apurv Kumar ◽  
Dharmil Baldev

2020 ◽  
Vol 25 (4) ◽  
pp. 430
Author(s):  
Dharmil Baldev ◽  
Apurv Kumar ◽  
Pavan Chauhan ◽  
M. Muthukumar ◽  
Sanjay Kumar Shukla

Sign in / Sign up

Export Citation Format

Share Document