Vortex-induced vibration dynamics of a flexible fluid-conveying marine riser subjected to axial harmonic tension

Author(s):  
Xiaodong Zhang ◽  
Ruyi Gou ◽  
Wenwu Yang ◽  
Xueping Chang
2011 ◽  
Vol 30 (4) ◽  
pp. 96-101 ◽  
Author(s):  
Min Lou ◽  
Wenyi Dong ◽  
Haiyan Guo

2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Jun Liu ◽  
Zhigang Du ◽  
Xiaoqiang Guo ◽  
Liming Dai ◽  
Liang Huang ◽  
...  

Vortex-induced vibration (VIV) is one of the most common dynamic mechanisms that cause damage to marine risers. Hamilton’s variational principle is used to establish a vortex-induced vibration (VIV) model of a flexible riser in which the wake oscillator model is used to simulate cross-flow (CF) and inline flow (IL) vortex-induced forces and their coupling, taking into account the effect of the top tension and internal flow in the riser. The VIV model is solved by combining the Newmark-β and Runge–Kutta methods and verified with experimental data from the literature. Combining Option 1 and Option 2 failure assessment diagrams (FADs) in the BS7910 standard, a fracture failure assessment model for a marine riser with circumferential semielliptical outside surface cracks is established. Using the VIV model and FAD failure assessment chart, the effects of riser length, inside/outside flows, and top tension on the VIV response and safety assessment of marine risers with outside surface cracks are investigated. It is shown that increasing the top tension can inhibit the lateral displacement amplitude and bending stress in a riser, but excessive top tension can increase the axial stress in the riser, which counteracts the decrease in the bending stress, so that the effect of top tension on crack safety is not significant. The increasing outside flow velocity significantly increases the lateral vibration amplitude and bending stress in the riser and reduces the crack safety. When other parameters remain unchanged, increasing riser length has no significant effect on the vibration amplitude of the lower part of the riser.


2021 ◽  
pp. 2150248
Author(s):  
Jin-Long Duan ◽  
Xu Wang ◽  
Ke Chen

The dynamics of a full-scale pipe conveying fluid inside is investigated based on the finite element method (FEM). During the numerical simulation, the Euler–Bernoulli beam equations are used to model the motion of the full-scale pipe while the effect of internal flow is considered. And the semi-empirical time-domain model is applied to simulate the external hydrodynamic forces exerted on the pipe. Then the typical vortex-induced vibration (VIV) characteristics of the full-scale pipe considering both internal and external flows are analyzed. The results show that with the increase of the internal flow velocity, the natural frequencies of the full-scale pipe decrease and the in-line (IL) and cross-flow (CF) dominating modes are increased. Furthermore, the dominating frequencies in both IL and CF directions are not notably changed. And the IL and CF root-mean-square (RMS) values of amplitudes fluctuate at around the stable values due to the stable external hydrodynamic forces. It should be noticed that the IL and CF RMS strain values of the full-scale pipe are increased, especially for high external and internal flow velocities. The maximal RMS strain values in both IL and CF directions appear next to the pipe top, which could have an influence on the motion of the ship on the sea surface.


Sign in / Sign up

Export Citation Format

Share Document