3D resistivity model of 1D vertical electrical sounding (VES) data for groundwater potential and aquifer protective capacity assessment: a case study

Author(s):  
Kolawole Isaac Arowoogun ◽  
Olawale Olakunle Osinowo
2020 ◽  
Vol 4 (2) ◽  
pp. 99-102
Author(s):  
Johnson C. Ibuot ◽  
Moses M. M. Ekpa ◽  
Doris O. Okoroh ◽  
Aniefiok S. Akpan Emmanuel T. Omeje

Geoelectric survey employing Vertical Electrical Sounding (VES) was carried out in order to assess the groundwater repositories. A total of seven soundings were obtained with their layer resistivity, thickness and depth within the maximum electrode separation. The geoelectric parameters obtained were used to estimate the Dar-Zarrouk parameters (longitudinal conductance and transverse resistance), hydraulic conductivity and transmissivity. The result shows the aquifer resistivity ranging from 77.14 to 784.76 Ωm, with thickness ranging from 28.78 to 80.04 m. The longitudinal conductance have values ranging from 0.071 to 0.825 Ω-1 while the values of hydraulic conductivity and transmissivity range from 1.087 to 5.881 m/day and 60.180 to 374.031 𝑚2/day respectively. The contour maps generated show the variation of these parameters across the subsurface, and areas with poor protective capacity were delineated. The results also delineate the groundwater potential of the study area as moderate, while the corrosivity rating indicates non-corrosive and slightly corrosive.


2020 ◽  
Vol 4 (2) ◽  
pp. 102-104
Author(s):  
Johnson C. Ibuot ◽  
Moses M. M. Ekpa ◽  
Doris O. Okoroh ◽  
Aniefiok S. Akpan Emmanuel T. Omeje

Geoelectric survey employing Vertical Electrical Sounding (VES) was carried out in order to assess the groundwater repositories. A total of seven soundings were obtained with their layer resistivity, thickness and depth within the maximum electrode separation. The geoelectric parameters obtained were used to estimate the Dar-Zarrouk parameters (longitudinal conductance and transverse resistance), hydraulic conductivity and transmissivity. The result shows the aquifer resistivity ranging from 77.14 to 784.76 Ωm, with thickness ranging from 28.78 to 80.04 m. The longitudinal conductance have values ranging from 0.071 to 0.825 Ω-1 while the values of hydraulic conductivity and transmissivity range from 1.087 to 5.881 m/day and 60.180 to 374.031 𝑚2/day respectively. The contour maps generated show the variation of these parameters across the subsurface, and areas with poor protective capacity were delineated. The results also delineate the groundwater potential of the study area as moderate, while the corrosivity rating indicates non-corrosive and slightly corrosive.


2016 ◽  
Vol 4 (1) ◽  
pp. 1 ◽  
Author(s):  
Chika Osele ◽  
Ajana Onwuemesi ◽  
Emmanuel Anakwuba ◽  
Augustine Chinwuko

<p>Surface geo-electrical survey using vertical electrical sounding (VES) method has been carried out in Onitsha and environs in southwestern part of Anambra state in order to determine the aquifer characteristics and groundwater potential of the area. Eleven vertical electrical soundings were carried out within the area of study using schlumberger array configuration. The interpretation of the vertical electrical sounding (VES) data revealed three to five geoelectric units with depth to the aquiferous layers ranging from 21 to 78m and resistivity of the saturated layers varying between 20 and 5600 ohm-m. Aquifer characteristics such as transmissivity and hydraulic conductivity calculated from interpretated VES result ranged from 2.55m2/day to 29.01m2/day and 0.03m/day to 1.37m/day respectively. This result shows that the water saturated sandstone units of the study area is hydrological good and capable of producing optimum groundwater yield. Furthermore, borehole could be drilled at depth between 40 and 110m in the area for sustainable water supply and hydrochemical study carried out to determine the water quality for domestics and municipal purposes.</p>


2021 ◽  
Vol 30 (1) ◽  
pp. 43-52
Author(s):  
Kenechukwu A. Ifeanyichukwu ◽  
Elizabeth Okeyeh ◽  
Okechukwu E. Agbasi ◽  
Onwe I. Moses ◽  
Ogechukwu Ben-Owope

In Nnewi, Anambra State Nigeria, twenty vertical electrical sounding (VES) were performed to delineate vulnerability and transmissivity of identified aquifer within the study area. Hydraulic parameters (transverse resistance, longitudinal conductivity, hydraulic conductivity and transmissivity) were delineated from geoelectrical parameters (depth, thickness, and apparent resistance). The geo- parameters of the aquifer: apparent resistance from 1000.590 to 1914.480, thickness from 42.850 – 66.490 m and 65.530 to 100.400 m of depth. The estimated hydraulic parameters of the aquifers are transverse resistance 54264.383 - 104568.898 Ωm, longitudinal conductance 0.029 – 0.062 mho, hydraulic conductivity 0.664 – 2.015 m/day and transmis- sivity between 4.167 and 13.963 m2/day. All aquifers have poor protective capacity, 40 percent of the aquifers have low classification with smaller withdrawal potential for local groundwater supply, while 60 percent of the delineated aquifer has intermediate classification and withdrawal potential for local groundwater supply. Due to its groundwater supply potential and protective capacity, the eastern part of the study area has stronger groundwater potential.


Sign in / Sign up

Export Citation Format

Share Document