scholarly journals Comparison of the Spreading Characters of Fire Products in the Typical Metro Stations of Washington, D.C., and Guangzhou

Author(s):  
Heng Yu

AbstractFire is one of the most common disasters that threaten the safety of the crowd in metro stations. Due to the variations in the design of metro stations, the hazard posed by the spreading products of the fire can pose different risks. The typical structures of metro stations in Guangzhou and Washington, D.C., are very different from each other. In Washington, D.C., the “high-dome” structure is predominant in the construction of metro stations, while in Guangzhou, most metro stations have the “flat ceiling” structure. In this article, a numerical modeling for fire dynamic simulation is used to predict and compare the spreading characters of fire products (the smoke height change, the temperature distribution and the visibility change) when fires with 2.5 MW heat release rate occur in the platform center and at the platform end in the two kinds of metro stations. The results show that, in the same fire scenario, the lowest smoke heights monitored in the Guangzhou model is 0.6 m (fire at the platform end) and 0.8 m (fire in the platform center) above the safe smoke height in 360 s after a fire breaks out, while it is 6.15 m (fire in the platform center) and 6.2 m (fire at the platform end) above the smoke height in the Washington model. The temperature increment in the Guangzhou model is 23 °C (fire in the platform center) to 29 °C (fire at the platform end) in 360 s after the fire breaks out, while the temperature increment in the same period in the Washington model is 8.5 °C (fire at the platform end) to 9 °C (fire in the platform center). The visibility of most areas on the platform of the Guangzhou model is about 1 m no matter the fire is in the platform center or at the platform end at 360 s after the fire begins, while in the Washington model, the visibility of most areas is 1.5–13.5 mm (fire at the platform end) to 4–14 m (fire in the platform center) at the same moment. Based on the results, the environment is worse when the fire happens at the end of the platform than that when the fire happens in the platform center of the Guangzhou model. While the fire location has fewer impacts on the smoke height, temperature, and visibility in the Washington model, metro stations with a high-dome structure can be beneficial to fire evacuation safety; however, the construction cost can be high. Metro stations with flat ceiling are widely used in more cities for it has lower construction cost; to compensate for its weaker abilities under fire conditions, it is suggested that smoke exhaust systems should be carefully and fully considered.

2014 ◽  
Vol 659 ◽  
pp. 353-358
Author(s):  
Gelu Coman ◽  
Cristian Iosifescu ◽  
Valeriu Damian

The paper presents the experimental and theoretical study for temperature distribution around the cooling pipes of an ice rink pad. The heat transfer in the skating rink track is nonstationary and phase changing. In case of skating rinks equipped with pipe registers, the temperature field during the ice formation process can’t be modeled by analytical methods. The experimental research was targeted on finding the temperatures in several points of the pad and also details on ice shape and quality around the pipes. The temperatures measured on the skating ring surface using thermocouples is impossible due to the larger diameter of the thermocouple bulb compared with the air-water surfaces thickness. For this reason we used to measure the temperature by thermography method, thus reducing the errors The experimental results were compared against the numerical modeling using finite elements.


2010 ◽  
Vol 42 (1) ◽  
pp. 99-124 ◽  
Author(s):  
A.K. Shukla ◽  
A. Mondal ◽  
A. Upadhyaya

The present study compares the temperature distribution within cylindrical samples heated in microwave furnace with those achieved in radiatively-heated (conventional) furnace. Using a two-dimensional finite difference approach the thermal profiles were simulated for cylinders of varying radii (0.65, 6.5, and 65 cm) and physical properties. The influence of susceptor-assisted microwave heating was also modeled for the same. The simulation results reveal differences in the heating behavior of samples in microwaves. The efficacy of microwave heating depends on the sample size and its thermal conductivity.


2009 ◽  
Vol 419-420 ◽  
pp. 29-32 ◽  
Author(s):  
Tung-Hsin Yeh ◽  
Jiin Yuh Jang ◽  
Yu Bin Chen ◽  
Der Her Wang

In order to inspect on wall condition inside the coke oven, an inspection device has been developed to protect a camera inside and sustains high temperature long enough so that it can be permanently-installed on the pusher ram beam. The temperature of the coking chamber during operation is about 1200 °C while the maximum tolerable temperature of a camera is less than 40 °C. The device has to function as a good thermal insulator with cooling element for the camera at the pusher head and for signal cables along the beam. In this paper, the necessary conditions of the inspective device were found out by building a three-dimensional numerical model of the device to simulate the temperature distribution inside the device with CFD commercial software.


2007 ◽  
Vol 26 (4) ◽  
pp. 373-378
Author(s):  
Masayuki Mizuno ◽  
Shin-ichi Tsuburaya ◽  
Shigeru Yamada ◽  
Takeyoshi Tanaka ◽  
Masahiro Morita ◽  
...  