Rovibrational line width of polar diatomic molecules diluted in rare gases. Application to HCl in dense Ar.

1992 ◽  
Vol 266 ◽  
pp. 295-301
Author(s):  
A. Padilla ◽  
J.R. Pérez ◽  
A. Calvo Hernández ◽  
F. Mauricio
1982 ◽  
Vol 15 (3) ◽  
pp. 439-450 ◽  
Author(s):  
J M Mestdagh ◽  
J Berlande ◽  
J Cuvellier ◽  
P de Pujo ◽  
A Binet

1976 ◽  
Vol 32 ◽  
pp. 49-55 ◽  
Author(s):  
F.A. Catalano ◽  
G. Strazzulla

SummaryFrom the analysis of the observational data of about 100 Ap stars, the radii have been computed under the assumption that Ap are main sequence stars. Radii range from 1.4 to 4.9 solar units. These values are all compatible with the Deutsch's period versus line-width relation.


Author(s):  
William Krakow

It has long been known that defects such as stacking faults and voids can be quenched from various alloyed metals heated to near their melting point. Today it is common practice to irradiate samples with various ionic species of rare gases which also form voids containing solidified phases of the same atomic species, e.g. ref. 3. Equivalently, electron irradiation has been used to produce damage events, e.g. ref. 4. Generally all of the above mentioned studies have relied on diffraction contrast to observe the defects produced down to a dimension of perhaps 10 to 20Å. Also all these studies have used ions or electrons which exceeded the damage threshold for knockon events. In the case of higher resolution studies the present author has identified vacancy and interstitial type chain defects in ion irradiated Si and was able to identify both di-interstitial and di-vacancy chains running through the foil.


Author(s):  
James B. Pawley

Past: In 1960 Thornley published the first description of SEM studies carried out at low beam voltage (LVSEM, 1-5 kV). The aim was to reduce charging on insulators but increased contrast and difficulties with low beam current and frozen biological specimens were also noted. These disadvantages prevented widespread use of LVSEM except by a few enthusiasts such as Boyde. An exception was its use in connection with studies in which biological specimens were dissected in the SEM as this process destroyed the conducting films and produced charging unless LVSEM was used.In the 1980’s field emission (FE) SEM’s came into more common use. The high brightness and smaller energy spread characteristic of the FE-SEM’s greatly reduced the practical resolution penalty associated with LVSEM and the number of investigators taking advantage of the technique rapidly expanded; led by those studying semiconductors. In semiconductor research, the SEM is used to measure the line-width of the deposited metal conductors and of the features of the photo-resist used to form them. In addition, the SEM is used to measure the surface potentials of operating circuits with sub-micrometer resolution and on pico-second time scales. Because high beam voltages destroy semiconductors by injecting fixed charges into silicon oxide insulators, these studies must be performed using LVSEM where the beam does not penetrate so far.


1989 ◽  
Vol 86 ◽  
pp. 853-859 ◽  
Author(s):  
Federico Moscardó ◽  
José Pérez-Jordá ◽  
Emilio San-Fabián

Sign in / Sign up

Export Citation Format

Share Document