Elevated intraocular pressure, pigment dispersion and dark hypopyon in endogenous endophthalmitis from Listeria monocytogenes

1992 ◽  
Vol 37 (2) ◽  
pp. 117-124 ◽  
Author(s):  
Dean Eliott ◽  
Terrence P. O'Brien ◽  
W.Richard Green ◽  
Henry D. Jampel ◽  
Morton F. Goldberg
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Wei Wei ◽  
Xueqing Yu ◽  
Lu Yang ◽  
Chan Xiong ◽  
Xu Zhang

Abstract Background With the rapid development of intraocular collamer lens (ICL) operation, it is foreseeable that we will encounter a large number of glaucoma patients with ICL implantation history. However, our current understanding of the treatment of glaucoma patients with ICL is limited. Hence we report a rare case of refractory glaucoma after intraocular collamer lens and intraocular lens implantation in a patient who underwent unsuccessful transscleral cyclophotocoagulation, which led to intraocular collamer lens displacement, angle closure and uncontrolled intraocular pressure. Case presentation A 39-year-old woman presented with intractably elevated intraocular pressure in the right eye. Since her intraocular collamer lens implantation surgery in 2017, her intraocular pressure had remained over 40 mmHg while using 3 types of anti-glaucoma medications. The patient had a history of phacoemulsification and posterior chamber phakic intraocular lens implantation for complicated cataracts secondary to uveitis in 2006. On gonioscope examination, there were signs of pigment dispersion, and the anterior chamber angle was open. Ultrasound biomicroscopy examination showed contact and rubbing between the intraocular collamer lens and posterior surface of the iris. And typical advanced glaucomatous optic neuropathy and visual field defects were observed. Transscleral cyclophotocoagulation was performed to control the intraocular pressure and prevent further visual field loss. However, the intraocular collamer lens was displaced after transscleral cyclophotocoagulation, which resulted in formation of a shallow anterior chamber 1 week later, angle closure and loss of intraocular pressure control 1 month later, even though the maximum dose of anti-glaucoma medication was used. Finally, an Ahmed glaucoma valve was successfully implanted in her anterior chamber, and the glaucoma was controlled, as observed at the 10-month follow-up. Conclusions Pigment dispersion is a common phenomenon after intraocular collamer lens implantation and may accelerate the progression of glaucoma. Transscleral cyclophotocoagulation should be carefully considered in glaucoma patients with elevated intraocular pressure after intraocular collamer lens implantation, given that transscleral cyclophotocoagulation may cause intraocular collamer lens displacement.


2015 ◽  
Vol 6 (2) ◽  
pp. 239-245 ◽  
Author(s):  
Aditya Kelkar ◽  
Rachana Shah ◽  
Jai Kelkar ◽  
Shreekant Kelkar ◽  
Ekta Arora

Sutureless, glueless, scleral fixation of an intraocular lens is a known technique of fixing a lens in the scleral pockets. However, this technique is applied to single-piece and toric lenses instead of 3-piece lenses, allowing the advantage of the use of premium lenses in patients with poor capsular support. Favourable results without complications of pigment dispersion, iris transillumination defects, dysphotopsia, elevated intraocular pressure, intraocular hemorrhage and cystoid macular edema with a well-centered, stable intraocular lens have been observed in the 3-month postoperative period in both cases.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Maiko Maruyama-Inoue ◽  
Tatsuya Inoue ◽  
Shaheeda Mohamed ◽  
Yoko Kitajima ◽  
Shoko Ikeda ◽  
...  

AbstractThe purpose of this study was to report the incidence of elevated intraocular pressure (IOP) after intravitreal injection (IVI) of anti-vascular endothelial growth factor (VEGF) in Japanese patients with age-related macular degeneration (AMD). A retrospective study of chart review of patients who underwent ≥ 10 intravitreal anti-VEGF injections between April 2009 and December 2019 was conducted. Elevated IOP was defined as IOP ≥ 25 mmHg at one visit. Cases with elevated IOP resulting from IVI were identified. Furthermore, the association between elevated IOP and some parameters, as the risk factors that influence elevated IOP, was investigated. A total of 402 eyes of 370 patients were included in this study. Twenty-eight eyes of 26 patients (7.0%) were identified as cases with elevated IOP after IVI. The mean time of elevation after baseline was 50.6 ± 26.5 months. History of glaucoma (p = 0.021; odds ratio, 5.85), treatment modality (p = 0.019; odds ratio, 6.32), and total number of injections (p = 0.003; odds ratio, 1.03) were significantly associated with elevated IOP. A late complication of elevated IOP is associated with IVI in patients with AMD. Particularly, history of glaucoma and treat and extend regimen with frequent injections were found to be risk factors of elevated IOP.


2021 ◽  
pp. 538-542
Author(s):  
Yuko Mano ◽  
Kei Mizobuchi ◽  
Tomoyuki Watanabe ◽  
Akira Watanabe ◽  
Tadashi Nakano

A 88-year-old female who was being treated for end-stage pseudoexfoliation syndrome was referred to our hospital for treatment of dislocated intraocular lens (IOL) and the elevated intraocular pressure (IOP) and in the right eye (RE). At the first visit to our hospital, best-corrected visual acuity (BCVA) was 0.2 in the RE and 0.02 in the left eye (LE). IOP was 47 mm Hg in the RE and 21 mm Hg in the LE. Slit-lamp examination showed no abnormalities in anterior segments and dislocated IOL in the RE. Fundus photograph showed optic disc pallor in both eyes. We performed the combined therapy of flanged intrascleral IOL fixation with the double-needle technique and trabeculectomy. Throughout the follow-up period, BCVA slightly improved from 0.2 to 0.4 in the RE. The angle of tilt of the IOL was 6.6, 7.9, and 8.7° as measured by swept-source optical coherence tomography at 1, 4, and 6 months after the surgery, respectively. The IOP remained less than 10 mm Hg without having to administer any other glaucoma medications. Furthermore, any complications associated with the surgery were not confirmed.


Sign in / Sign up

Export Citation Format

Share Document