Load bearing capacity of bored piles, a problem not yet satisfactorily solved - some suggestions

Geotecnia ◽  
2019 ◽  
Vol 147 ◽  
pp. 103-116
Author(s):  
Jorge Luís Augusto Almada ◽  
◽  
Verônica Ricken Marques ◽  
Raquel Souza Teixeira ◽  
Jeselay Hemetério Cordeiro dos Reis ◽  
...  

2019 ◽  
Vol 828 ◽  
pp. 194-201
Author(s):  
Lidia Kondratieva ◽  
Vladimir Konyushkov ◽  
Le Van Trong ◽  
Vladimir Kirillov

The purpose of the study is to establish accuracy of determining the load-bearing capacity of bored piles according to the method specified in Regulations 24.13330.2011 "Pile foundations". Relevance of the topic is determined by the following: the load-bearing capacity of a pile is a fundamental indicator affecting all subsequent activities related to foundation design, and accuracy of analytical solutions for complex engineering and geological conditions is highly questionable. Field tests of bored piles were carried out in engineering and geological conditions of Saint Petersburg with deformation modulus from 10 to 40 MPa at a load in the range from 1,000 to 6,300 kN, at achievement of absolute settlement of 40 mm. Piles with a diameter from 0.15 to 0.88 m and a length from 10 to 47 m were made using various technologies: using casing, using slurry, using a flight auger. Following the results of field tests, diagrams of load-bearing capacity of piles according to the material, depending on geometrical parameters and manufacturing techniques, diagrams of actual and designed load-bearing capacity of piles were plotted. Approximating functions to describe the dependences were obtained. According to the analysis of the results, it is possible to conclude that the load-bearing capacity of the bored pile during field tests is 1.4–1.7 times higher than the load-bearing capacity of the pile designed according to Regulations 24.13330.2011; the average share of the load-bearing capacity along the side surface of the pile was 65% and under the pile toe — 35%.


2020 ◽  
Vol 62 (1) ◽  
pp. 55-60
Author(s):  
Per Heyser ◽  
Vadim Sartisson ◽  
Gerson Meschut ◽  
Marcel Droß ◽  
Klaus Dröder

2017 ◽  
Vol 68 (1) ◽  
pp. 94-100
Author(s):  
Oana Tanculescu ◽  
Adrian Doloca ◽  
Raluca Maria Vieriu ◽  
Florentina Mocanu ◽  
Gabriela Ifteni ◽  
...  

The load-bearing capacity and fracture pattern of direct inlay-retained FRC FDPs with two different cross-sectional designs of the ponticwere tested. The aim of the study was to evaluate a new fibre disposition. Two types of composites, Filtek Bulk Fill Posterior Restorative and Filtek Z250 (3M/ESPE, St. Paul, MN, USA), and one braided polyethylene fibre, Construct (Kerr, USA) were used. The results of the study suggested that the new tested disposition of the fibres prevented in some extend the delamination of the composite on buccal and facial sides of the pontic and increased the load-bearing capacity of the bridges.


Sign in / Sign up

Export Citation Format

Share Document