High resolution electron microscope lattice images of powdered gallstones

1987 ◽  
Vol 18 (4) ◽  
pp. 281-290 ◽  
Author(s):  
Ying-Shiung Lee
Author(s):  
Mihir Parikh

It is well known that the resolution of bio-molecules in a high resolution electron microscope depends not just on the physical resolving power of the instrument, but also on the stability of these molecules under the electron beam. Experimentally, the damage to the bio-molecules is commo ly monitored by the decrease in the intensity of the diffraction pattern, or more quantitatively by the decrease in the peaks of an energy loss spectrum. In the latter case the exposure, EC, to decrease the peak intensity from IO to I’O can be related to the molecular dissociation cross-section, σD, by EC = ℓn(IO /I’O) /ℓD. Qu ntitative data on damage cross-sections are just being reported, However, the microscopist needs to know the explicit dependence of damage on: (1) the molecular properties, (2) the density and characteristics of the molecular film and that of the support film, if any, (3) the temperature of the molecular film and (4) certain characteristics of the electron microscope used


Author(s):  
G.Y. Fan ◽  
O.L. Krivanek

Full alignment of a high resolution electron microscope (HREM) requires five parameters to be optimized: the illumination angle (beam tilt) x and y, defocus, and astigmatism magnitude and orientation. Because neither voltage nor current centering lead to the correct illumination angle, all the adjustments must be done on the basis of observing contrast changes in a recorded image. The full alignment can be carried out by a computer which is connected to a suitable image pick-up device and is able to control the microscope, sometimes with greater precision and speed than even a skilled operator can achieve. Two approaches to computer-controlled (automatic) alignment have been investigated. The first is based on measuring the dependence of the overall contrast in the image of a thin amorphous specimen on the relevant parameters, the other on measuring the image shift. Here we report on our progress in developing a new method, which makes use of the full information contained in a computed diffractogram.


1982 ◽  
Vol 21 ◽  
Author(s):  
H. Yoshida ◽  
H. Hashimoto ◽  
Y. Yokota ◽  
M. Takeda

ABSTRACTAtomic structures of G.P. zones and solute clusters in Al-Cu and Cu-Be alloys are studied by the atom resolution electron microscope images. The images of plate-like G.P. zones appear as dotted images with various brightnesses along (200) lattice planes. The solute clusters are also observed along (111) lattice planes.


1983 ◽  
Vol 219 (1215) ◽  
pp. 111-117 ◽  

The calcite coccoliths from the alga Emiliania huxleyi (Lohmann) Hay and Mohler have been studied by ultra-high resolution electron microscopy. This paper describes the two different types of structure observed, one in the upper elements, the other in the basal plate, or lower element. The former consisted of small, microdomain structures of 300-500 Å (1 Å = 10 -10 m) in length with no strong orientation. At places along these elements, and particularly in the junction between stem and head pieces, triangular patterns of lattice fringes were observed indicating multiple nucleation sites in the structure. In contrast, the lower element consisted of a very thin single crystalline sheet of calcite which could be resolved into a two dimensional lattice image, shown by a computer program that is capable of simulating electron diffraction patterns and lattice images to be a [421] zone of calcite. A possible mechanism for these growth patterns in the formation of coccoliths is discussed, together with the relevance of such mechanisms to biomineralization generally.