MEDIUM TEMPERATURE SOLAR THERMAL SYSTEMS

1986 ◽  
pp. 967-976 ◽  
Author(s):  
R.E. Collins
Author(s):  
Bandi Sai Mukesh ◽  
Sudipto Mukhopadhyay ◽  
Ashish Mondal ◽  
Laltu Chandra

Abstract Solar thermal energy systems are future sustainable solutions for both domestic as well as industrial use. Solar thermal systems operating in medium temperature range (373-673 K) require concentrated solar-thermal heating (CSH). In this work, a comprehensive numerical tool is developed to design and study multipurpose on-sun CSH system. The model uses a combined Monte-Carlo ray tracing, finite difference method and all heat transfer modes. The model is validated with in-house experiment, which demonstrates its predictive capability. Next, the tool is used to optimise the cavity receiver geometry and predict the performance of the optimised CSH system under different direct normal irradiance (DNI) conditions. A CSH system using Therminol D12 as HTF is presented. Therminol D12 HTF based system is predicted to take longer time than the system using water as HTF, for heating water to a specified temperature because of the heat exchanger effectiveness. However, the designed CSH system using Therminol D12 can attain higher temperatures than water without pressurization and through the heat exchanger can be used as multipurpose system suitable for cooking, laundry, sterilization, process industry etc.


2021 ◽  
Vol 11 (9) ◽  
pp. 4100
Author(s):  
Rasa Supankanok ◽  
Sukanpirom Sriwong ◽  
Phisan Ponpo ◽  
Wei Wu ◽  
Walairat Chandra-ambhorn ◽  
...  

Evacuated-tube solar collector (ETSC) is developed to achieve high heating medium temperature. Heat transfer fluid contained inside a copper heat pipe directly affects the heating medium temperature. A 10 mol% of ethylene-glycol in water is the heat transfer fluid in this system. The purpose of this study is to modify inner structure of the evacuated tube for promoting heat transfer through aluminum fin to the copper heat pipe by inserting stainless-steel scrubbers in the evacuated tube to increase heat conduction surface area. The experiment is set up to measure the temperature of heat transfer fluid at a heat pipe tip which is a heat exchange area between heat transfer fluid and heating medium. The vapor/ liquid equilibrium (VLE) theory is applied to investigate phase change behavior of the heat transfer fluid. Mathematical model validated with 6 experimental results is set up to investigate the performance of ETSC system and evaluate the feasibility of applying the modified ETSC in small-scale industries. The results indicate that the average temperature of heat transfer fluid in a modified tube increased to 160.32 °C which is higher than a standard tube by approximately 22 °C leading to the increase in its efficiency by 34.96%.


2018 ◽  
Vol 176 ◽  
pp. 99-109 ◽  
Author(s):  
Angeliki Kylili ◽  
Paris A. Fokaides ◽  
Andreas Ioannides ◽  
Soteris Kalogirou

2021 ◽  
pp. 60-71
Author(s):  
Tshewang Darjay ◽  
Cheku Dorji ◽  
Tshewang Lhendup ◽  
Martin Elborg

The Royal Government of Bhutan has accorded the highest priority towards diversifying the energy-mix through the promotion of renewable energy technologies. There is a national target to generate 3 MW equivalent of energy from the installation of solar thermal systems alone. However, little investment and priority are given for development of solar thermal applications. Some of the present existing solar water heating (SWH) systems are exhibiting faults which leads to low consumer confidence in SWH technology due to the non-functioning of previous installations which is very detrimental in this introductory stage. This study aims to identify problems of existing SWH systems through field surveys and develop a draft guideline to avoid faults in the future. To analyse the problems with existing SWH systems in Bhutan, the first phase of the study consists of collecting secondary information and opinion from the relevant government sector, local installing companies and end-users. The information on the manufacturer’s products, policy barriers, markets and consumer challenges is also collected. Base on this information, findings on the limitation of existing policy instrument and gap in demand and supply side is described. The second phase of the study comprises field visits to existing SWH system sites. The field surveys of twelve representative existing SWH systems are analyzed. Out of twelve sites, eight SWH systems had critical faults which causes major failure of the system and the other four sites had minor faults. To analyse the faults of existing SWH systems, faults are classified into design faults, plumbing circuit faults, solar collector faults, absorber faults, installation faults and user behavior faults. The major faults which lead to the failure of the existing SWH system are plumbing failure, condensation inside the collector and absorber tube leakage. The causes and solutions of the faults are discussed.


2012 ◽  
Vol 30 ◽  
pp. 134-143 ◽  
Author(s):  
Christian Holter ◽  
Bernhard Gerardts ◽  
Philip Ohnewein ◽  
Angela Dröscher ◽  
Franz Feichtner ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document