X-Ray Fluorescence Analysis of Trace Elements in Coal and Solvent Refined Coal

Author(s):  
John W. Prather ◽  
James A. Guin ◽  
Arthur R. Tarrer
Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


2020 ◽  
Author(s):  
E. V. Kochergina ◽  
A. O. Vagina ◽  
A. O. Taukin ◽  
A. V. Abramov ◽  
G. M. Bunkov ◽  
...  

1968 ◽  
Vol 22 (4) ◽  
pp. 321-324 ◽  
Author(s):  
Frank Cuttitta ◽  
Harry J. Rose

A new approach to solving matrix problems in x-ray fluorescence analysis of trace elements has been applied to the determination of bromine in saline waters and zinc in silicates. The method requires no prior knowledge of the chemical composition of the sample. Marked matrix effects are minimized by dilution, and the problem of variable backgrounds due to residual matrix effects is solved by using a slope-ratio technique. In this proposed technique, the slope of a standard curve prepared from pure solutions is compared with that of spiked samples. The ratio of the slopes of these two curves permits the calculation of an adjusted background which does not significantly differ from that of an absorbent impregnated with the sample matrix free of the element sought. Experimental parameters concerning the technique are presented. The excellent agreement of the zinc and bromine data with analytical results obtained by more conventional methods suggests that the technique can be used for the determination of other trace constituents in geologic materials. Application of the slope-ratio technique to other modes of instrumental analysis appears feasible.


1993 ◽  
Vol 22 (4) ◽  
pp. 248-251 ◽  
Author(s):  
M. O. Figueiredo ◽  
M. J. Basto ◽  
K. Abbas ◽  
P. Chevallier ◽  
Z. Melo ◽  
...  

2010 ◽  
Vol 59 (6) ◽  
pp. 521-530 ◽  
Author(s):  
Hiroshi Hasegawa ◽  
Nozomu Iwasaki ◽  
Atsushi Suzuki ◽  
Teruya Maki ◽  
Shinjiro Hayakawa

Sign in / Sign up

Export Citation Format

Share Document