Graphene and 2D-Like Nanomaterials: Different Biofunctionalization Pathways for Electrochemical Biosensor Development

2018 ◽  
pp. 1-35 ◽  
Author(s):  
Riccarda Antiochia ◽  
Cristina Tortolini ◽  
Federico Tasca ◽  
Lo Gorton ◽  
Paolo Bollella
2020 ◽  
Vol 1135 ◽  
pp. 73-82 ◽  
Author(s):  
Zhen Yang ◽  
Mingji Li ◽  
Hongji Li ◽  
Huayi Li ◽  
Cuiping Li ◽  
...  

Nanomaterials ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 416
Author(s):  
Zari Tehrani ◽  
Hina Yaqub Abbasi ◽  
Anitha Devadoss ◽  
Jonathan Edward Evans ◽  
Owen James Guy

Electrochemical biosensors using carbon-based electrodes are being widely developed for the detection of a range of different diseases. Since their sensitivity depends on the surface coverage of bioreceptor moieties, it necessarily depends on the surface coverage of amine precursors. Electrochemical techniques, using ferrocene carboxylic acid as a rapid and cheap assay, were used to assess the surface coverage of amino-phenyl groups attached to the carbon electrode. While the number of electrons transferred in the first step of diazotisation indicated a surface coverage of 8.02 ± 0.2 × l0−10 (mol/cm2), and those transferred in the second step, a reduction of nitrophenyl to amino-phenyl, indicated an amine surface coverage of 4–5 × l0−10 (mol/cm2), the number of electrons transferred during attachment of the amine coupling assay compound, ferrocene carboxylic acid, indicated a much lower available amine coverage of only 2.2 × l0−11 (mol/cm2). Furthermore, the available amine coverage was critically dependent upon the number of cyclic voltammetry cycles used in the reduction, and thus the procedures used in this step influenced the sensitivity of any subsequent sensor. Amine coupling of a carboxyl terminated anti-beta amyloid antibody specific to Aβ(1-42) peptide, a potential marker for Alzheimer’s disease, followed the same pattern of coverage as that observed with ferrocene carboxylic acid, and at optimum amine coverage, the sensitivity of the differential pulse voltammetry sensor was in the range 0–200 ng/mL with the slope of 5.07 µA/ng·mL−1 and R2 = 0.98.


Author(s):  
Jing Zhang ◽  
Meifeng Hou ◽  
Guanyu Chen ◽  
Huifang Mao ◽  
Wenqian Chen ◽  
...  

2021 ◽  
pp. 107801
Author(s):  
José M. R. Flauzino ◽  
Rafaela C. S. Peres ◽  
Lívia M. Alves ◽  
Jussara G. Vieira ◽  
Júlia G. dos Santos ◽  
...  

2021 ◽  
Vol 882 ◽  
pp. 115029
Author(s):  
Mengke Yu ◽  
Yu-Tao Li ◽  
Youfan Hu ◽  
Lina Tang ◽  
Fan Yang ◽  
...  

RSC Advances ◽  
2015 ◽  
Vol 5 (64) ◽  
pp. 51990-51999 ◽  
Author(s):  
Fei Liu ◽  
Guiming Xiang ◽  
Liqun Zhang ◽  
Dongneng Jiang ◽  
Linlin Liu ◽  
...  

lncRNA biosensor based on single-wall carbon nanotubes wrapped with Au–Rh hollow nanospheres (Au/Rh-HNP@SWCNT) complex signal amplification and an l-Cys Au nano-film provided ultrasensitive detection for the nuclear paraspeckle assembly transcript 1 (NEAT1).


Sign in / Sign up

Export Citation Format

Share Document