gold nanostructure
Recently Published Documents


TOTAL DOCUMENTS

121
(FIVE YEARS 36)

H-INDEX

20
(FIVE YEARS 7)

2021 ◽  
Vol 171 ◽  
pp. 106788
Author(s):  
Silvia Dortez ◽  
Maria Cristina González ◽  
Agustín G. Crevillen ◽  
Alberto Escarpa

2021 ◽  
Author(s):  
Qi Cai ◽  
Valentina Castagnola ◽  
Luca Boselli ◽  
Alirio Moura ◽  
Hender Lopez ◽  
...  

Automatized approaches for nanoparticle synthesis and characterization represent a great asset to their applicability in the biomedical field by improving reproducibility and standardization, which help to meet the selection criteria of regulatory authorities. The scaled-up production of nanoparticles with carefully defined characteristics, including intrinsic morphological features, minimal intra-batch, batch-to-batch, and operator variability, is an urgent requirement to elevate nanotechnology towards more trustable biological and technological applications. In this work, microfluidic approaches were employed to achieve fast mixing and good reproducibility in synthesizing a variety of gold nanostructures. The microfluidic setup allowed exploiting spatial resolution to investigate the growth evolution of the complex nanoarchitectures. By physically isolating intermediate reaction fractions, we performed an advanced characterization of the shape properties during their growth, not possible with routine characterization methods. Employing an in-house developed method to assign a specific identity to shapes, we followed the particle growth/deformation process and identified key reaction parameters for more precise control of the generated morphologies. Besides, this investigation led to the optimization of a one-pot multi-size and multi-shape synthesis of a variety of gold nanoparticles. In summary, we describe an optimized platform for highly controlled synthesis and a novel approach for the mechanistic study of shape-evolving nanomaterials.


Small ◽  
2021 ◽  
Vol 17 (15) ◽  
pp. 2170066
Author(s):  
Intan Rosalina Suhito ◽  
Novi Angeline ◽  
Kwang‐Ho Lee ◽  
Huijung Kim ◽  
Chun Gwon Park ◽  
...  

2021 ◽  
Vol 56 (17) ◽  
pp. 10249-10263
Author(s):  
Samir V. Jenkins ◽  
Seunghyun Jung ◽  
Shruti Shah ◽  
Paul C. Millett ◽  
Ruud P. M. Dings ◽  
...  

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Shanshan Chen ◽  
Zhiguang Liu ◽  
Huifeng Du ◽  
Chengchun Tang ◽  
Chang-Yin Ji ◽  
...  

AbstractKirigami, with facile and automated fashion of three-dimensional (3D) transformations, offers an unconventional approach for realizing cutting-edge optical nano-electromechanical systems. Here, we demonstrate an on-chip and electromechanically reconfigurable nano-kirigami with optical functionalities. The nano-electromechanical system is built on an Au/SiO2/Si substrate and operated via attractive electrostatic forces between the top gold nanostructure and bottom silicon substrate. Large-range nano-kirigami like 3D deformations are clearly observed and reversibly engineered, with scalable pitch size down to 0.975 μm. Broadband nonresonant and narrowband resonant optical reconfigurations are achieved at visible and near-infrared wavelengths, respectively, with a high modulation contrast up to 494%. On-chip modulation of optical helicity is further demonstrated in submicron nano-kirigami at near-infrared wavelengths. Such small-size and high-contrast reconfigurable optical nano-kirigami provides advanced methodologies and platforms for versatile on-chip manipulation of light at nanoscale.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Wenlong Chang ◽  
Jing Zhao ◽  
Lu Liu ◽  
Xiaoming Xing ◽  
Chao Zhang ◽  
...  

Nanotechnology is playing a major role in the field of medical diagnosis, in particular with the biosensor and bioimaging. It improves the performance of the desired system dramatically by displaying higher selectivity and sensitivity. Carbon nanomaterial, gold nanostructure, magnetite nanoparticle, and silica substrate are the most popular nanomaterials greatly contributed to make the affordable and effective biosensor at low-cost. This research work is introducing a new sensing strategy with graphene oxide-constructed triangular electrodes to diagnose Alzheimer’s disease (AD). MicroRNA-137 (miRNA-137) was found as a suitable biomarker for AD, and the sensing method was established here to detect miRNA-137 on the complementary sequence. To enhance the immobilization of capture miRNA-137, gold nanostar (GNS) was conjugated with capture miRNA and immobilized on the GO-modified surface through an amine linker. This immobilization process enhanced the hybridization of the target and reaches the detection limit at 10 fM with the sensitivity of 1 fM on the linear curve with a regression coefficient of 0.9038. Further control sequences of miRNA-21 and single and triple base mismatched miRNA-137 did not show a significant response in current changes, indicating the specific miRNA-137 detection for diagnosing AD.


Chemosensors ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 37
Author(s):  
Agnes Purwidyantri ◽  
Ya-Chung Tian ◽  
Gardin Muhammad Andika Saputra ◽  
Briliant Adhi Prabowo ◽  
Hui-Ling Liu ◽  
...  

The nanostructuring of a sensing membrane is performed through colloidal nanosphere lithography (NSL) techniques with a tiny polystyrene nanobead template 100 nm in size. The solvent ratio adjustment has been proven to be effective in assisting the monolayer deposition of small templating particles with minimal defects. Two distinct structures, namely, a billowy gold nanostructure (BGN) where the nanobead template is left unetched and a gold nanoframe array (GNA) with a regular ring-like structure after template removal, are used for the extended-gate field-effect transistor (EGFET) electrodes. The GNA structure generates an electroactive surface area significantly (~20%) larger than its geometrical area as well as a greater surface roughness than the BGN. When integrated with the portable constant voltage–constant current (CVCC) FET circuitry for pH screening to determine the optimized measurement conditions for H2O2 sensing, the GNA sensing membrane also shows more improved Nernstian sensitivity at ~50 mV/pH than the BGN electrode. The more optimized sensitivity is then proven using the GNA in the detection of H2O2, the most common representative reactive oxygen species (ROS) involved in the environment, food, and neurodegenerative diseases, such as Parkinson´s and Alzheimer´s diseases. The GNA electrode has a sensitivity of 70.42 mV/log µM [H2O2] and a limit of detection (LoD) of 1.183 µM H2O2. The integrated ion sensing system employing unique, highly ordered gold array gate electrodes and a portable CVCC circuit system has shown a stable real-time output voltage signal, representing an alternative to bulky conventional FET devices for potential on-site H2O2 detection.


Nanomaterials ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 376
Author(s):  
Lu He ◽  
Mahfujur Rahaman ◽  
Teresa I. Madeira ◽  
Dietrich R.T. Zahn

Tip-enhanced Raman spectroscopy (TERS) has experienced tremendous progress over the last two decades. Despite detecting single molecules and achieving sub-nanometer spatial resolution, attaining high TERS sensitivity is still a challenging task due to low reproducibility of tip fabrication, especially regarding very sharp tip apices. Here, we present an approach for achieving strong TERS sensitivity via a systematic study of the near-field enhancement properties in the so-called gap-mode TERS configurations using the combination of finite element method (FEM) simulations and TERS experiments. In the simulation study, a gold tip apex is fixed at 80 nm of diameter, and the substrate consists of 20 nm high gold nanodiscs with diameter varying from 5 nm to 120 nm placed on a flat extended gold substrate. The local electric field distributions are computed in the spectral range from 500 nm to 800 nm with the tip placed both at the center and the edge of the gold nanostructure. The model is then compared with the typical gap-mode TERS configuration, in which a tip of varying diameter from 2 nm to 160 nm is placed in the proximity of a gold thin film. Our simulations show that the tip-nanodisc combined system provides much improved TERS sensitivity compared to the conventional gap-mode TERS configuration. We find that for the same tip diameter, the spatial resolution achieved in the tip-nanodisc model is much better than that observed in the conventional gap-mode TERS, which requires a very sharp metal tip to achieve the same spatial resolution on an extended metal substrate. Finally, TERS experiments are conducted on gold nanodisc arrays using home-built gold tips to validate our simulation results. Our simulations provide a guide for designing and realization of both high-spatial resolution and strong TERS intensity in future TERS experiments.


Sign in / Sign up

Export Citation Format

Share Document