scholarly journals Instrumental methods in surface property analysis of magnetic nanoparticles

Nanomaterials ◽  
2021 ◽  
pp. 691-697
Author(s):  
G. Carlin Geor Malar ◽  
Muthulingam Seenuvasan ◽  
Kannaiyan Sathish Kumar ◽  
Madhava Anil Kumar
Author(s):  
E. M. Timanin ◽  
N. S. Sydneva ◽  
A. A. Zakharova

Introduction. To date there is a lack of studies dedicated to the objectification of the palpation data obtained by a specialist during the osteopathic examination. The issue of the evidence of the results of osteopathic correction still remains important. Search for instrumental methods allowing to register and to measure various palpation phenomena and manifestations of somatic dysfunctions is very relevant for the development of osteopathy as a science. It is also very important to find objective characteristics of these methods.Goal of research — to study viscoelastic characteristics of the soft tissues of the lower legs by palpation and instrumental methods before and after osteopathic correction.Materials and methods. 22 volunteers (12 women and 10 men) aged 18–23 years without complaints of the musculoskeletal system were examined. Osteopathic diagnostics and measurement of the viscoelastic properties of muscles were carried out by the method of vibration viscoelastometry before and after osteopathic correction.Results. Correlation analysis by Spearman showed that the subjective assessment of an osteopath positively correlated with both elasticity (r=0,43, p<0,05) and viscosity of soft issues (r=0,29, p<0,05). For the gastrocnemius muscle, this pattern was even more pronounced — for elasticity r=0,51, p<0,05, for viscosity =0,34, p<0,05. After osteopathic correction no changes in the elasticity of the soft tissues were observed. The viscosity of the tissues reduced, but in the projection of the gastrocnemius muscle, these changes were not statistically significant (p=0,12), whereas in the projection of the soleus muscle statistically significant changes (p=0,034) were observed.Conclusion. Changes in the viscoelastic properties of tissues demonstrated that the effects of osteopathic correction with the use of myofascial mobilization techniques, articulation mobilization techniques, and lymphatic drainage techniques were not obvious. The elasticity of soft tissues of the lower legs did not change, while the viscosity decreased, especially in the projection of the soleus muscles. This effect of the osteopathic correction can be associated with the effect of thixotropy — the transformation of gel-like intercellular substance into sol. Thus, the research showed that vibration viscoelastometry can be used for the objectifi cation of the condition of soft tissues and of the effects of osteopathic correction.


Author(s):  
D. Pletcher ◽  
R. Greff ◽  
R. Peat ◽  
L. M. Peter ◽  
J. Robinson
Keyword(s):  

2020 ◽  
Vol 23 (9) ◽  
pp. 1064-1076
Author(s):  
O.V. Ovchar

Subject. Under rapid changes in the external economic environment, new forms and methods of State regulation of oil and gas industries, especially, improving the taxation and tax regulation instruments become relevant. Objectives. The study aims to provide an original interpretation of methods of improving the tax administration of major taxpayers in the oil and gas sector applied at the present stage. Methods. I employ normative and holistic approaches to examine taxation efficiency in the oil and gas sector, general scientific and special methods of scientific cognition, i.e. retrospective, system analysis, observation, classification, instrumental methods of grouping, sampling, comparison and synthesis, as well as evolutionary and dynamic analysis. Results. I consider basic problems and solutions in the sphere of tax administration of major taxpayers of Russian oil and gas industries. The paper offers a package of measures and recommendations aimed at improving the efficiency of tax regulation, underpins the applied approach to tax administration of organizations operating in the oil and gas sector. Conclusions and Relevance. Our country needs a comprehensive program for tax administration of the entire technological cycle: from upstream operations to full-scale import substitution of consumer goods.


PIERS Online ◽  
2009 ◽  
Vol 5 (3) ◽  
pp. 231-234 ◽  
Author(s):  
Tsung-Han Tsai ◽  
Long-Sheng Kuo ◽  
Ping-Hei Chen ◽  
Chin-Ting Yang

2017 ◽  
Author(s):  
Bo Tian ◽  
Peter Svedlindh ◽  
Mattias Strömberg ◽  
Erik Wetterskog

In this work, we demonstrate for the first time, a ferromagnetic resonance (FMR) based homogeneous and volumetric biosensor for magnetic label detection. Two different isothermal amplification methods, <i>i.e.</i>, rolling circle amplification (RCA) and loop-mediated isothermal amplification (LAMP) are adopted and combined with a standard electron paramagnetic resonance (EPR) spectrometer for FMR biosensing. For RCA-based FMR biosensor, binding of RCA products of a synthetic Vibrio cholerae target DNA sequence gives rise to the formation of aggregates of magnetic nanoparticles. Immobilization of nanoparticles within the aggregates leads to a decrease of the net anisotropy of the system and a concomitant increase of the resonance field. A limit of detection of 1 pM is obtained with an average coefficient of variation of 0.16%, which is superior to the performance of other reported RCA-based magnetic biosensors. For LAMP-based sensing, a synthetic Zika virus target oligonucleotide is amplified and detected in 20% serum samples. Immobilization of magnetic nanoparticles is induced by their co-precipitation with Mg<sub>2</sub>P<sub>2</sub>O<sub>7</sub> (a by-product of LAMP) and provides a detection sensitivity of 100 aM. The fast measurement, high sensitivity and miniaturization potential of the proposed FMR biosensing technology makes it a promising candidate for designing future point-of-care devices.<br>


2020 ◽  
Vol 84 (11) ◽  
pp. 1362-1365
Author(s):  
A. V. Komina ◽  
R. N. Yaroslavtsev ◽  
Y. V. Gerasimova ◽  
S. V. Stolyar ◽  
I. A. Olkhovsky ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document