VEGF-Capturing Aligned Electrospun Polycaprolactone/Gelatin Nanofibers Promote Patellar Ligament Regeneration

Author(s):  
Zhengchao Yuan ◽  
Dandan Sheng ◽  
Muhammad Shafiq ◽  
Liping Jiang ◽  
Atta ur Rehman Khan ◽  
...  
Keyword(s):  
1996 ◽  
Vol 09 (04) ◽  
pp. 165-171 ◽  
Author(s):  
D. A. Hulse ◽  
M. R. Slater ◽  
J. F. Hunter ◽  
W. A. Hyman ◽  
B. A. Shelley

SummaryA test apparatus that allowed the stifle to move in five degrees of freedom was used to determine the effect of graft location, graft preload, and flexion angle at the time of graft fixation on the tensile graft forces experienced by a replacement graft material used to simulate reconstruction of the cranial cruciate ligament deficient stifle. Two graft locations (tibial insertion site of the patellar ligament and tibial insertion site of the cranial cruciate ligament), two graft preloads (5 N and 20 N), and three flexion angles at the time of graft fixation (15°, 30° and 90°) were examined. The tibial insertion site and preload did not have as great an effect on graft force as did the flexion angle of the limb at time of graft fixation. Graft forces were highest when reconstructions were performed with the limb in 90° of flexion (ρ <0.0001). This study supports the notion that intracapsular grafts should be fixed with the limb in a normal standing angle.A five degree of freedom test apparatus was used to evaluate the effect of graft location, graft preload, and limb flexion angle at time of graft fixation on reconstructions of the cranial cruciate ligament deficient stifle. Our results suggest that intracapsular grafts should not be fixed with the limb in 90° of flexion, but in a normal standing angle.


1993 ◽  
Vol 06 (02) ◽  
pp. 85-92 ◽  
Author(s):  
G. L. Coetzee

SummaryThe immediate postoperative biomechanical properties of an “underand-over” cranial cruciate ligament (CCL) replacement technique consisting of fascia lata and the lateral onethird of the patellar ligament, were compared with that of a modified intra- and extracapsular “under-and-over-the-top” (UOTT) method. The right CCL in twelve adult dogs was dissected out and replaced with an autograft. The contralateral, intact CCL served as the control. In group A, the graft was secured to the lateral femoral condyle with a spiked washer and screw. In group B the intracapsular graft was secured to the lateral femoro-fabellar ligament, and the remainder to the patellar tendon. Both CCL replacement techniques exhibited a 2.0 ± 0.5 mm anterior drawer immediately after the operation. After skeletonization of the stifles, the length and cross-sectional area of the intact CCL and CCL substitutes were determined. Each bone-ligament unit was tested in linear tension to failure at a fixed distraction rate of 15 mm/s with the stifle in 120° flexion. Data was processed to obtain the corresponding material parameters (modulus, stress and strain in the linear loading region, and energy absorption to maximum load).The immediate postoperative structural and material properties of the “under-and-over” cranial cruciate ligament replacement technique with autogenous fascia lata, were compared to that of a modified intra- and extracapsular “under-and-over-the-top” (UOTT) method. The combined UOT T technique was slightly stronger (6%), but allowed 2.8 ± 0.9 mm more cranial tibial displacement at maximum linear force.


1989 ◽  
Vol 02 (02) ◽  
pp. 59-66 ◽  
Author(s):  
G. J. Miller ◽  
Maron Calderwood Mays ◽  
L. Tilmant ◽  
P. A. Indelicato ◽  
M. S. Bloomberg

2012 ◽  
Vol 81 (4) ◽  
pp. 403-407 ◽  
Author(s):  
Dávid Kňazovický ◽  
Valent Ledecký ◽  
Marián Hluchý ◽  
Marek Ďurej

The aim of this study was to evaluate if the modified Insall Salvati (IS) method can be applied for the canine patient despite differences of proximal tibial morphology, and if such potential differences are also seen in dogs with cranial cruciate ligament rupture. Insall Salvati method is a simple and convenient method for determination of the vertical position of patella, by dividing the length of patella by length of the patellar ligament. The influence of the variable proximal tibial morphology on the modified (IS) index was measured and the value of modified IS index in healthy dogs (n = 25) was compared with dogs with cranial cruciate ligament rupture (n = 26). Medio-lateral radiographs of 102 stifles were evaluated. Patellar ligament length (PLL), patellar length (PL), modified IS ratio and the height of insertion point of patellar ligament on tibial tuberosity were measured. Data of the IS ratio were compared with the value of the height of the insertion point with no significant difference (P = 0.36). There was no significant difference (P = 0.07) in the PLL:PL ratio between dogs affected or unaffected with cranial cruciate ligament rupture. Based on the results of this study we can conclude that the morphology of the cranio-proximal tibia and the height of insertion point of the patellar ligament do not have an influence on the value of the modified IS index both in healthy dogs and in dogs with cranial cruciate ligament rupture.


1996 ◽  
Vol 322 ◽  
pp. 174-178 ◽  
Author(s):  
Z. U. Isiklar ◽  
K. E. Varner ◽  
R. W. Lindsey ◽  
J. R. Bocell ◽  
D. M. Lintner

Author(s):  
Esa V. Eskelinen ◽  
Ari P. Suhonen ◽  
Juha V. Virolainen ◽  
William D. Liska

Abstract Objectives The purpose of this study was to compare the load at failure, stiffness and mode of failure between three types of tibial tuberosity transposition fixation techniques: (a) pin and figure-8 tension band wire (Pin-TBW), (b) locking plate with pin and a tension band wire (Plate-Pin-TBW) and (c) locking plate with a pin (Plate-Pin). Methods Six pairs of raccoon dog cadaveric tibiae were tested in Phase I Pin-TBW versus Plate-Pin-TBW and seven pairs in Phase II Plate-Pin-TBW versus Plate-Pin. One limb of each pair was randomly assigned to one of two groups for each phase. A tensile force was applied to the patellar ligament until construct failure. Results Pin-TBW (342N ± 54.7N) failed at a lower load than Plate-Pin-TBW (469N ± 77.3N), p = 0.00748, with all Pin-TBW failing by fracture and the majority of Plate-Pin-TBW failing by rupture of patellar ligament. Pin-TBW group Phase I, normalized with Plate-Pin-TBW Phase I, failed at a lower load than Plate-Pin group Phase II, normalized with Plate-Pin-TBW Phase II, p = 0.00467. There was no significant difference in mean load at failure, stiffness or mode at failure between the groups in the Phase II study. Clinical Significance Although ex vivo mechanical testing does not replicate the postoperative live dog or cat, these results demonstrate lower construct strength of the Pin-TBW construct compared with the Plate-Pin construct in the raccoon dog cadaver model.


2015 ◽  
Vol 50 (6) ◽  
pp. 743-746
Author(s):  
Rodrigo Pires e Albuquerque ◽  
Idemar Monteiro da Palma ◽  
Hugo Cobra ◽  
Alan de Paula Mozella ◽  
Victor Vaques

Sign in / Sign up

Export Citation Format

Share Document