Late Reconstruction of Patellar Ligament Ruptures Using Ilizarov External Fixation

1996 ◽  
Vol 322 ◽  
pp. 174-178 ◽  
Author(s):  
Z. U. Isiklar ◽  
K. E. Varner ◽  
R. W. Lindsey ◽  
J. R. Bocell ◽  
D. M. Lintner
1996 ◽  
Vol 09 (04) ◽  
pp. 165-171 ◽  
Author(s):  
D. A. Hulse ◽  
M. R. Slater ◽  
J. F. Hunter ◽  
W. A. Hyman ◽  
B. A. Shelley

SummaryA test apparatus that allowed the stifle to move in five degrees of freedom was used to determine the effect of graft location, graft preload, and flexion angle at the time of graft fixation on the tensile graft forces experienced by a replacement graft material used to simulate reconstruction of the cranial cruciate ligament deficient stifle. Two graft locations (tibial insertion site of the patellar ligament and tibial insertion site of the cranial cruciate ligament), two graft preloads (5 N and 20 N), and three flexion angles at the time of graft fixation (15°, 30° and 90°) were examined. The tibial insertion site and preload did not have as great an effect on graft force as did the flexion angle of the limb at time of graft fixation. Graft forces were highest when reconstructions were performed with the limb in 90° of flexion (ρ <0.0001). This study supports the notion that intracapsular grafts should be fixed with the limb in a normal standing angle.A five degree of freedom test apparatus was used to evaluate the effect of graft location, graft preload, and limb flexion angle at time of graft fixation on reconstructions of the cranial cruciate ligament deficient stifle. Our results suggest that intracapsular grafts should not be fixed with the limb in 90° of flexion, but in a normal standing angle.


1993 ◽  
Vol 06 (02) ◽  
pp. 85-92 ◽  
Author(s):  
G. L. Coetzee

SummaryThe immediate postoperative biomechanical properties of an “underand-over” cranial cruciate ligament (CCL) replacement technique consisting of fascia lata and the lateral onethird of the patellar ligament, were compared with that of a modified intra- and extracapsular “under-and-over-the-top” (UOTT) method. The right CCL in twelve adult dogs was dissected out and replaced with an autograft. The contralateral, intact CCL served as the control. In group A, the graft was secured to the lateral femoral condyle with a spiked washer and screw. In group B the intracapsular graft was secured to the lateral femoro-fabellar ligament, and the remainder to the patellar tendon. Both CCL replacement techniques exhibited a 2.0 ± 0.5 mm anterior drawer immediately after the operation. After skeletonization of the stifles, the length and cross-sectional area of the intact CCL and CCL substitutes were determined. Each bone-ligament unit was tested in linear tension to failure at a fixed distraction rate of 15 mm/s with the stifle in 120° flexion. Data was processed to obtain the corresponding material parameters (modulus, stress and strain in the linear loading region, and energy absorption to maximum load).The immediate postoperative structural and material properties of the “under-and-over” cranial cruciate ligament replacement technique with autogenous fascia lata, were compared to that of a modified intra- and extracapsular “under-and-over-the-top” (UOTT) method. The combined UOT T technique was slightly stronger (6%), but allowed 2.8 ± 0.9 mm more cranial tibial displacement at maximum linear force.


1989 ◽  
Vol 02 (02) ◽  
pp. 59-66 ◽  
Author(s):  
G. J. Miller ◽  
Maron Calderwood Mays ◽  
L. Tilmant ◽  
P. A. Indelicato ◽  
M. S. Bloomberg

2020 ◽  
Vol 99 (8) ◽  

Introduction: The study compares the results of open reduction using volar locking plates with ligamentotaxis by external fixation in fractures of distal radius type 2R3C according to AO classification. Methods: A retrospective study evaluating the results of osteosynthesis in patients with distal radius fractures type 2R3C according to AO classification, operated until December 2018. The ORIF method with volar locking plates (LCP) was used in 54 patients, and closed reduction with ligamentotaxis using external fixation (EF) was used in 33 patients. The mean age of the patients was 46.7 years in the LCP group and 59.6 years in the EF group. All were evaluated for their X-ray and functional outcomes and according to the Green and O’Brien score at 6 and 12 months after surgery. Results: According to X-rays at 12 months in the LCP group, the mean sagittal tilt was 10.13°, the mean radial inclination was 23.89°, and the mean radial length was 11.84 mm. In the EF group, the mean sagittal tilt was 6.32°, the mean radial inclination was 24.78°, and the mean radial length was 9.89 mm. According to the Green and O’Brien score, we recorded a mean score of 84.44 points in the LCP group at 12 month; we achieved good and excellent results in 83.33% of the patients and no poor result was observed. In the EF group the final mean score was 77.27; good and excellent results were achieved in 45.46% of the patients and a poor result in one patient. Conclusion: Based on the results in our group of patients, the internal type osteosynthesis using LCP implants can be recommended as a first-choice technique in the treatment of 2R3C fractures according to AO classification.


2013 ◽  
Vol 22 (04) ◽  
pp. 316-320 ◽  
Author(s):  
Robert K. Lark ◽  
John S. Lewis Jr. ◽  
Tyler Steven Watters ◽  
Robert D. Fitch

Sign in / Sign up

Export Citation Format

Share Document