scholarly journals Sequential ultra-high density contact mapping of persistent atrial fibrillation: An efficient technique for rotors identification

2018 ◽  
Vol 10 (1) ◽  
pp. 92 ◽  
Author(s):  
D. Latcu ◽  
S. Bun ◽  
B. Enache ◽  
A. Wedn ◽  
A. Amourha ◽  
...  
EP Europace ◽  
2017 ◽  
Vol 19 (suppl_3) ◽  
pp. iii245-iii245
Author(s):  
DG. Latcu ◽  
A. Amourha ◽  
B. Enache ◽  
SS. Bun ◽  
T. Delassi ◽  
...  

EP Europace ◽  
2017 ◽  
Vol 19 (suppl_3) ◽  
pp. iii44-iii45 ◽  
Author(s):  
DG. Latcu ◽  
A. Amourha ◽  
B. Enache ◽  
SS. Bun ◽  
T. Delassi ◽  
...  

2021 ◽  
Vol 12 ◽  
Author(s):  
Merle Friederike Fenner ◽  
Giulia Gatta ◽  
Stefan Sattler ◽  
Marion Kuiper ◽  
Eva Melis Hesselkilde ◽  
...  

BackgroundSmall-conductance Ca2+-activated K+ (KCa2) channels have been proposed as a possible atrial-selective target to pharmacologically terminate atrial fibrillation (AF) and to maintain sinus rhythm. However, it has been hypothesized that the importance of the KCa2 current—and thereby the efficacy of small-conductance Ca2+-activated K+ current (IK,Ca) inhibition—might be negatively related to AF duration and the extent of AF-induced remodeling.Experimental Approach and MethodsTo address the hypothesis of the efficacy of IK,Ca inhibition being dependent on AF duration, the anti-arrhythmic properties of the IK,Ca inhibitor NS8593 (5 mg/kg) and its influence on atrial conduction were studied using epicardial high-density contact mapping in horses with persistent AF. Eleven Standardbred mares with tachypacing-induced persistent AF (42 ± 5 days of AF) were studied in an open-chest experiment. Unipolar AF electrograms were recorded and isochronal high-density maps analyzed to allow for the reconstruction of wave patterns and changes in electrophysiological parameters, such as atrial conduction velocity and AF cycle length. Atrial anti-arrhythmic properties and adverse effects of NS8593 on ventricular electrophysiology were evaluated by continuous surface ECG monitoring.ResultsIK,Ca inhibition by NS8593 administered intravenously had divergent effects on right and left AF complexity and propagation properties in this equine model of persistent AF. Despite global prolongation of AF cycle length, a slowing of conduction in the right atrium led to increased anisotropy and electrical dissociation, thus increasing AF complexity. In contrast, there was no significant change in AF complexity in the LA, and cardioversion of AF was not achieved.ConclusionsIntra-atrial heterogeneity in response to IK,Ca inhibition by NS8593 was observed. The investigated dose of NS8593 increased the AF cycle length but was not sufficient to induce cardioversion. In terms of propagation properties during AF, IK,Ca inhibition by NS8593 led to divergent effects in the right and left atrium. This divergent behavior may have impeded the cardioversion success.


2020 ◽  
Vol 36 (12) ◽  
pp. 1956-1964 ◽  
Author(s):  
Pablo B. Nery ◽  
Wael Alqarawi ◽  
Girish M. Nair ◽  
Mouhannad M. Sadek ◽  
Calum J. Redpath ◽  
...  

2019 ◽  
Vol 30 (12) ◽  
pp. 2704-2712 ◽  
Author(s):  
Michael Wolf ◽  
René Tavernier ◽  
Ziad Zeidan ◽  
Milad El Haddad ◽  
Yves Vandekerckhove ◽  
...  

EP Europace ◽  
2020 ◽  
Vol 22 (11) ◽  
pp. 1653-1658
Author(s):  
Giulio Conte ◽  
Kyoko Soejima ◽  
Carlo de Asmundis ◽  
Jolie Bruno ◽  
Fabio Cattaneo ◽  
...  

Abstract Aims To assess the value of high-density mapping (HDM) in revealing undetected incomplete pulmonary vein isolation (PVI) after the fourth-generation cryoballoon (CB4G) ablation compared to the previous cryoballoon’s versions. Methods and results Consecutive patients with paroxysmal or early-persistent atrial fibrillation (AF) undergoing CB ablation as the index procedure, assisted by HDM, were retrospectively included in this study. A total of 68 patients (52 males; mean age: 60 ± 12 years, 58 paroxysmal AF) were included, and a total of 272 veins were mapped. Fourth-generation cryoballoon with the new spiral mapping catheter (SMC) was used in 35 patients (51%). Time to PVI was determined in 102/132 (77%) and in 112/140 (80%) veins during second-generation cryoballoon/third-generation cryoballoon (CB2G/CB3G) and CB4G ablation, respectively (P = 0.66). There was a statistically significant difference in terms of discrepancy rate between the SMC and the mini-basket catheter in PV detection after CB4G and CB2G/CB3G ablation(1.4% vs. 7.6%; P = 0.01). A total of 57 patients (84%) remained free of symptomatic AF during a mean follow-up of 9.8 ± 4.6 months. Conclusion High-density mapping after cryoballoon ablation using CB4G and the new SMC identifies incomplete PVI, not detected by the new SMC, in a significantly lower proportion of veins compared to HDM performed after the other generation CB ablation.


Sign in / Sign up

Export Citation Format

Share Document