scholarly journals Exergy study of amine regeneration unit for diethanolamine used in refining gas sweetening: A real start-up plant

Author(s):  
Ahmed Y. Ibrahim ◽  
Fatma H. Ashour ◽  
Mamdouh A. Gadalla ◽  
Rania Farouq
Heliyon ◽  
2021 ◽  
Vol 7 (2) ◽  
pp. e06241
Author(s):  
Ahmed Y. Ibrahim ◽  
Fatma H. Ashour ◽  
Mamdouh A. Gadalla

2008 ◽  
Vol 48 (1) ◽  
pp. 249
Author(s):  
Anthea Condilis ◽  
Jon Even Vale ◽  
Tor-Erik Stranna

Aker Kværner Process Systems (AKPS) in Norway provided the monoethylene glycol (MEG) regeneration unit for BP’s Shah Deniz Gas Export Project. Design by AKPS began in 2003. The MEG unit was installed by May 2006 at the Sangachal Terminal outside Baku, Azerbaijan. MEG injection was selected to prevent hydrate formation in the pipelines conveying gas and condensate from the Shah Deniz gas field in the Caspian Sea to the onshore terminal. This MEG unit employs full stream reclamation, where reclamation (salts removal) is integrated into the reconcentration process (water removal). The commissioning of this MEG unit by BP was completed by November 2006 and the start-up phase was complete by May 2007. The chemistry of the MEG system was evaluated by AKPS during this period. Improved understanding of the chemistry has led to advances in the design of subsequent MEG units by AKPS. Two fundamental improvements are proposed for future MEG unit designs. One fundamental improvement is the use of a slip stream reclaimer for salts removal. Consequently, the reconcentration operation is not dependent on the operation of the reclaimer, greatly improving the availability and flexibility of the system. Another consequence of slip stream reclamation is the significant reduction in size of the reclaimer, and with this comes reduced capital investment and improved maintainability. The second fundamental improvement is the inclusion of pre-treatment operations for controlled precipitation and removal of low solubility salts originating from formation water and pipeline corrosion. Together with careful consideration of chemical additions to facilitate this precipitation, this design improvement is expected to prevent scaling in the downstream equipment. The function of the reclaimer is primarily to remove high solubility salts (chlorides). Improvements in the design of MEG regeneration units that are described above and the motives behind them are explored in detail.


2016 ◽  
Vol 21 (06) ◽  
pp. 70-73
Author(s):  
Christian Schünemann
Keyword(s):  

Bei einer Hochzeit hörte Nicolas Schulwitz (32) von einer zündenden Idee: Wie wäre es, mit einer Online-Video-Sprechstunde das Verhältnis von Arzt und Patient zu revolutionieren? Gesagt, getan. Schulwitz kündigte einen sicheren Job und gründete das Start-up-Unternehmen Patientus.


2019 ◽  
Vol 01 (02) ◽  
pp. 48-49
Author(s):  
Norbert Ruch
Keyword(s):  

Im Rahmen der 37. femak-Bundesfachtagung in Rotenburg an der Fulda gab es einen neuen Höhepunkt im Programmablauf. Der Berufsverband für Einkäufer und Logistiker im Krankenhaus veranstaltete zum ersten Mal einen Wettbewerb für Unternehmensgründer und innovative Ideen im Gesundheitswesen. Dabei durften sich drei junge Unternehmen vorstellen, die sich im Vorfeld qualifiziert hatten.