Assessment of Inflammation in Idiopathic Orbital Myositis With Fat-Suppressed T2-weighted Magnetic Resonance Imaging

2007 ◽  
Vol 143 (4) ◽  
pp. 718-720 ◽  
Author(s):  
Toshinobu Kubota ◽  
Hiroshi Kano
2019 ◽  
Vol 84 ◽  
pp. 142-146 ◽  
Author(s):  
Ahmed Razek ◽  
El-hadidy Mohamed El-Hadidy ◽  
Mohamed El-Said Moawad ◽  
Nader El-Metwaly ◽  
Amr Abd El-hamid El-Said

2021 ◽  
Vol 9 (7) ◽  
pp. 1781-1786
Author(s):  
Ze’ai Wang ◽  
Yanfeng Wang ◽  
Yuan Wang ◽  
Chaogang Wei ◽  
Yibin Deng ◽  
...  

Biomineralized iron oxide–polydopamine hybrid nanodots are constructed using albumin nanoreactors to facilitate contrast-enhanced T1-weighted magnetic resonance imaging as well as photothermal therapeutic efficacy.


Author(s):  
Rania Sobhy Abou khadrah ◽  
Haytham Haroon Imam

Abstract Background Differentiation between malignant and benign masses is essential for treatment planning and helps in improving the prognosis of malignant tumors; the aim of this work is to determine the role of diffusion-weighted magnetic resonance imaging (DW-MRI) and the apparent diffusion coefficient (ADC) in the differentiation between benign and malignant solid head and neck masses by comparing diagnostic performance of low b values (0.50 and 400 s/mm2) versus high b values (800 and 1000 s/mm2) and comparing the result with histopathological finding. Results The study included 60 patients (34 male and 26 female) with solid head and neck masses > 1 cm who referred to radiodiagnosis department for MRI evaluation. Multiple b values were used 50, 400, 800, and 1000 s/mm2 (at least 2 b values). DWI and ADC value of all 60 patients were acquired. Mean ADC values of both malignant and benign masses were statistically measured and compared, and cut off value was determined. Solid head and neck masses in our study DWI with the use of high b value 800 and 1000 s/mm2 were of higher significance (P value 0.001*). There was a significant difference in the mean ADC value between benign and malignant masses (P < 0.01); solid masses were divided into 2 categories: (a) malignant lesions 46.7% (n = 28) with mean ADC value (0.82 ± 0.19) × 10−3 s/mm2 and (b) benign lesions 53.3% (n = 32) with mean ADC value (2.05 ± 0.46) × 10−3 s/mm2) with ADC cutoff value of 1.0 × 10−3 s/mm2 and 94% sensitivity, 93% specificity, negative predictive value (NPV) = 94%, positive predictive value (PPV) 93%, and an accuracy of 93.5%. Conclusion The DWI with ADC mapping were valuable as non-invasive tools in differentiating between benign and malignant solid head and neck masses. The use of high b value 800 and 1000 s/mm2 was of higher significance (P value 0.001*) in differentiation between benign and malignant lesion than that with low b values 0, 50, and 400 s/mm2 (0.01). The mean ADC values were significantly lower in malignant solid masses. Attention had to be paid to the choice of b values in MRI-DWI in the head and neck region.


2019 ◽  
Vol 30 (4) ◽  
pp. 676-679
Author(s):  
Massimiliano Serafino ◽  
Matteo Scaramuzzi ◽  
Edoardo Villani ◽  
Paolo Nucci

Objective: To assess the efficacy of “Yokoyama Procedure,” on non-highly myopic patients with acquired esotropia and hypotropia. Methods: The study involved 10 eyes of 5 patients with eso-hypotropia. Inclusion criteria were acquired esotropic-hypotropic strabismus with lateral rectus inferior displacement and superior rectus nasal displacement confirmed by magnetic resonance imaging, refractive errors between ±6 D, and axial length < 27 mm. Range of full duction movements and maximum angles of abduction-sursumduction was measured in each eye before and after surgery. All patients underwent T1- and T2-weighted magnetic resonance imaging. The surgery was aimed at creating a junction between the muscle bellies of the superior and lateral rectus muscles. This junction was made approximately 14 mm behind the insertions using a non-absorbable mersilene 5/0 suture (Yokoyama procedure). Results: Mean patient age was 64.8 ± 4.8 years. The mean globe axial length was 25.4 ± 0.76 mm and a mean corresponding spherical equivalent refraction of −3.7 ± 1.7 D was observed. Eight eyes on 10 had mild limitation in abduction, while the remaining 2 had no limitation. Three out of 10 eyes showed a moderate limited sursumduction, 5 eyes were categorized as mild, and the remaining 2 had no limitation. No evident post-operative limitation was present in any eye, in both abduction and sursumduction (p < 0.01). Pre-operative esotropia and hypotropia were, respectively, 32 ± 11 prismatic diopters and 25 ± 5 prismatic diopters, and they were significantly reduced after surgery as 9 ± 1.7 prismatic diopters and 6 ±1 prismatic diopters (p = 0.043), respectively. Conclusion: Yokoyama procedure is an effective, fast, reversible procedure to face eso-hypotropic acquired strabismus, even in patients with a clear magnetic resonance imaging displacement of superior and lateral rectus muscles, and absence of globe dislocation and of elevated myopia.


Sign in / Sign up

Export Citation Format

Share Document