Numerical analysis of how ventilation conditions impact compartment fire suppression by water mist

2020 ◽  
Vol 136 ◽  
pp. 107021 ◽  
Author(s):  
Jaiho Lee
Author(s):  
Paolo E. Santangelo ◽  
Paolo Tartarini ◽  
Beatrice Pulvirenti ◽  
Paolo Valdiserri ◽  
Andre´ W. Marshall

Water-mist systems have become a promising technology in the fire-fighting field over the last twenty years. The present work is aimed at employing the available knowledge on water-mist sprays in an experimental and numerical analysis of the suppression mechanism. Therefore, a water-mist system has been operated within a typical fire case. Most notably, this latter is constituted by a heptane pool fire: experiments have been carried out inside a test chamber, where a set of thermocouples has conveniently been placed to evaluate the thermal transient at different locations of interest. Some free-combustion tests have been run as a benchmark to validate combustion models. Then, a typical water-mist nozzle has been inserted and activated to realize control, suppression and potential extinction of the generated fire. The recognized FDS (Fire Dynamics Simulator) and Fluent® codes have been challenged in reproducing the test case: thermal transient and suppression time have been considered as parameters for validation. Therefore, the water-mist spray has been modeled and the already mentioned results about its characterization have been implemented as initial or boundary conditions. Moreover, the fire scenario has been modeled as well. A good agreement between experimental and numerical results has been obtained, even under some approximations, with specific reference to combustion mechanisms.


Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3099 ◽  
Author(s):  
Ho Trong Khoat ◽  
Ji Tea Kim ◽  
Tran Dang Quoc ◽  
Ji Hyun Kwark ◽  
Hong Sun Ryou

Understanding fire characteristics under sprinkler spray is valuable for performance-based safety design. However, fire characteristics during fire suppression by sprinkler spray has seldom been studied in detail. In order to present a fire suppression model by sprinkler spray and determine the fire characteristics after sprinkler activation in a compartment, a numerical analysis was conducted using a fire dynamics simulator (FDS). A simple fire suppression model by sprinkler spray was calibrated by comparing ceiling temperatures from experimental data. An extinguishing coefficient of 3.0 was shown to be suitable for the fire suppression model. The effect of sprinkler spray on the smoke layer during fire suppression was explained, revealing a smoke logging phenomenon. In addition, the smoke, which spread under the influence of the sprinkler spray, was also investigated. The temperature, velocity, and mass flow rate of the smoke layer through the doorway was significantly reduced during fire suppression compared to a free burn case.


2020 ◽  
Vol 133 ◽  
pp. 230-242 ◽  
Author(s):  
Wei-Yi Liu ◽  
Chiun-Hsun Chen ◽  
Yi-Liang Shu ◽  
Wei-Ting Chen ◽  
Chi-Min Shu

2001 ◽  
Vol 10 (3) ◽  
pp. 277-294 ◽  
Author(s):  
B. YAO ◽  
W. K. CHOW

2014 ◽  
Vol 915-916 ◽  
pp. 356-361
Author(s):  
Zheng Wen Xie

FDS simulation software was used to establish the full size lampblack physics model of single wind pipe, using the orthogonal design method design of analog calculation conditions, research in the nozzle pressure, the droplet radius, nozzle, flow quantity and injection angle parameters under different conditions of water mist fire extinguishing effect. Based on a full-scale combustion and water mist fire extinguishing experiment, the water mist fire suppression was observed and test analysis etc, to better understand the flue water mist fire extinguishing feasibility, provides the theory basis for the design of efficient, reliable flue fire extinguishing system.


Sign in / Sign up

Export Citation Format

Share Document