Comparison of effective thermal conductivity in closed-loop vertical ground heat exchangers

2011 ◽  
Vol 31 (17-18) ◽  
pp. 3669-3676 ◽  
Author(s):  
Chulho Lee ◽  
Moonseo Park ◽  
Sunhong Min ◽  
Shin-Hyung Kang ◽  
Byonghu Sohn ◽  
...  
Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3919
Author(s):  
Yu Zhou ◽  
Asal Bidarmaghz ◽  
Nikolas Makasis ◽  
Guillermo Narsilio

Ground-source heat pump systems are renewable and highly efficient HVAC systems that utilise the ground to exchange heat via ground heat exchangers (GHEs). This study developed a detailed 3D finite element model for horizontal GHEs by using COMSOL Multiphysics and validated it against a fully instrumented system under the loading conditions of rural industries in NSW, Australia. First, the yearly performance evaluation of the horizontal straight GHEs showed an adequate initial design under the unique loads. This study then evaluated the effects of variable trench separations, GHE configurations, and effective thermal conductivity. Different trench separations that varied between 1.2 and 3.5 m were selected and analysed while considering three different horizontal loop configurations, i.e., the horizontal straight, slinky, and dense slinky loop configurations. These configurations had the same length of pipe in one trench, and the first two had the same trench length as well. The results revealed that when the trench separation became smaller, there was a minor increasing trend (0.5 °C) in the carrier fluid temperature. As for the configuration, the dense slinky loop showed an average that was 1.5 °C lower than those of the horizontal straight and slinky loop (which were about the same). This indicates that, when land is limited, compromises on the trench separation should be made first in lieu of changes in the loop configuration. Lastly, the results showed that although the effective thermal conductivity had an impact on the carrier fluid temperature, this impact was much lower compared to that for the GHE configurations and trench separations.


2012 ◽  
Vol 42 ◽  
pp. 77-83 ◽  
Author(s):  
Chulho Lee ◽  
Moonseo Park ◽  
The-Bao Nguyen ◽  
Byonghu Sohn ◽  
Jong Min Choi ◽  
...  

Energy ◽  
2013 ◽  
Vol 58 ◽  
pp. 655-663 ◽  
Author(s):  
G. Florides ◽  
E. Theofanous ◽  
I. Iosif-Stylianou ◽  
S. Tassou ◽  
P. Christodoulides ◽  
...  

2019 ◽  
Vol 192 ◽  
pp. 15-30 ◽  
Author(s):  
Iosifina Iosif Stylianou ◽  
Savvas Tassou ◽  
Paul Christodoulides ◽  
Lazaros Aresti ◽  
Georgios Florides

Energies ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3737
Author(s):  
Aneta Sapińska-Śliwa ◽  
Tomasz Sliwa ◽  
Kazimierz Twardowski ◽  
Krzysztof Szymski ◽  
Andrzej Gonet ◽  
...  

This work concerns borehole heat exchangers and their testing using apparatus for thermal response tests. In the theoretical part of the article, an equation was derived from the known equation of heat flow, on which the interpretation of the thermal response test was based. The practical part presents the results of several measurements taken in the AGH Laboratory of Geoenergetics. They were aimed at examining the potential heat exchange capacity between the heat carrier and rock mass. Measurement results in the form of graphs are shown in relation to the examined, briefly described wells. Result analysis made it possible to draw conclusions regarding the interpretation of the thermal response test. The method of averaging the measurement results was subjected to further study. The measuring apparatus recorded data at a frequency of one second, however such accuracy was too large to be analyzed efficiently. Therefore, an average of every 1 min, every 10 min, and every 60 min was proposed. The conclusions stemming from the differences in the values of effective thermal conductivity in the borehole heat exchanger, resulting from different data averaging, were described. In the case of three borehole heat exchangers, ground properties were identical. The effective thermal conductivity λeff was shown to depend on various borehole heat exchanger (BHE) designs, heat carrier flow geometry, and grout parameters. It is important to consider the position of the pipes relative to each other. As shown in the charts, the best (the highest) effective thermal conductivity λeff occurred in BHE-1 with a coaxial construction. At the same time, this value was closest to the theoretical value of thermal conductivity of rocks λ, determined on the basis of literature. The standard deviation and the coefficient of variation confirmed that the effective thermal conductivity λeff, calculated for different time intervals, showed little variation in value. The values of effective thermal conductivity λeff for each time interval for the same borehole exchanger were similar in value. The lowest values of effective thermal conductivity λeff most often appeared for analysis with averaging every 60 min, and the highest—for analysis with averaging every 1 min. For safety reasons, when designing (number of BHEs), safer values should be taken for analysis, i.e., lower, averaging every 60 min.


2015 ◽  
Vol 81 ◽  
pp. 288-297 ◽  
Author(s):  
Antonio Capozza ◽  
Angelo Zarrella ◽  
Michele De Carli