Energy and exergy analysis of a geothermal heat pump air conditioning system

2015 ◽  
Vol 86 ◽  
pp. 333-347 ◽  
Author(s):  
Roberto Baccoli ◽  
Costantino Mastino ◽  
Giuseppe Rodriguez
2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Silvia Cocchi ◽  
Sonia Castellucci ◽  
Andrea Tucci

The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling), through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP) uses the shallow ground as a source of heat, thus taking advantage of its seasonally moderate temperatures. GSHP must be coupled with geothermal exchangers. The model leads to design optimization of geothermal heat exchangers and to verify the operation of the geothermal plant.


2012 ◽  
Vol 433-440 ◽  
pp. 4952-4958
Author(s):  
Dilek Ozlem Esen

In this paper, a detailed energy and exergy analysis have been dealt with on experimental AAC (Automobile Air Conditioning) system with R134a as working refrigerant. For this aim, an experimental AAC system consisting of a laminated type evaporator, swash plate type compressor, a parallel flow type condenser, TXV(thermostatic expansion valve) and a receiver drier. The performance analysis of separate components of AAC system has been carried out under various compressor speeds and thermal loads. AAC system equipped with increasing compressor speed by three-phase electric motor controlled by frequency converter. Various thermal loads in the range of 1500 and 2850 W were applied to the system by means of electric heaters. The experiments were conducted at the condensing temperatures of 50-60 oC for each thermal load, and at the compressor speeds of 600, 800, 1000, 1200, 1400 rpm for each thermal load-condensing temperature combination. The refrigerant and air temperatures, refrigerant pressures, compressor speed, air velocity passing through the evaporator and thermal load were measured. Effects on system performance of such operational parameters as compressor speed, return air in the evaporator and condensing air temperatures have been experimentally evaluated and by means of energy and exergy analysis.


2008 ◽  
Vol 2008.47 (0) ◽  
pp. 99-100
Author(s):  
Ko WATANABE ◽  
Takayoshi SUZUKI ◽  
Hiroyuki SEKI ◽  
Masafumi SASAKI ◽  
Noboru ENDOH ◽  
...  

2012 ◽  
Vol 512-515 ◽  
pp. 168-171
Author(s):  
Wei Yu ◽  
Feng Chen ◽  
Hong Bo Li

This article on a villas in Langfang city, Hebei province, heating and air conditioning systems. According to the owners of the double requirement of energy saving and environmental protection to owners selection of solar energy and geothermal heat pump heating system combined. To better achieve heating and air conditioning energy saving operation of villas, the system can be run by optimizing the control scheme, time-sharing partition building heat adjustment.