scholarly journals Modeling of an Air Conditioning System with Geothermal Heat Pump for a Residential Building

2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Silvia Cocchi ◽  
Sonia Castellucci ◽  
Andrea Tucci

The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling), through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP) uses the shallow ground as a source of heat, thus taking advantage of its seasonally moderate temperatures. GSHP must be coupled with geothermal exchangers. The model leads to design optimization of geothermal heat exchangers and to verify the operation of the geothermal plant.

2012 ◽  
Vol 252 ◽  
pp. 433-437
Author(s):  
Zhi Yang Yuan

The ground-source heat pump is a system which takes the shallow surface soil energy as the source of heating and cooling. The temperature of ground source is relatively stable throughout the year, which makes the ground-source heat pump have the higher operation efficiency compared with the traditional air-conditioning system.Study on the ground-source heat pump with properties of thermal dynamics used in heating and air comditioning by ecomomic analysis is still an important issue. In this paper, the ground-source heat pump and the traditional heating and air-conditioning system have been compared in terms of their economic competitiveness. Firstly, it is required to compare the ground-source heat pump with the traditional heating method in terms of the heating economy. Afterwards, it is necessary to compare the ground-source heat pump with the conventional electric refrigeration in terms of the air-conditioning economy. Finally, it is needed to conduct the comprehensive and economic analysis for the ground-source heat pump and the boilers and air conditioning, which includes four programs.


2017 ◽  
Vol 27 (6) ◽  
pp. 805-817 ◽  
Author(s):  
Byung C. Kwag ◽  
Moncef Krarti

Ground medium can be utilized as a direct energy source to heat and cool buildings. In particular, ground source heat pump systems take advantage of the year-round mild deep earth temperature without a significant reliance on any external energy sources. However, the high installation cost of ground source heat pumps associated with high drilling cost of vertical boreholes often make these systems less cost-effective compared to conventional heating and cooling systems. Thermo-active foundations can be a viable solution to reduce ground source heat pump high installation costs by embedding heat exchangers within building foundation structures. Compared to ground source heat pumps, only limited analyses and research studies have been reported for thermo-active foundations especially for the US climates. In particular, no specific design guidelines have been reported for thermo-active foundations especially for US climates. In this paper, a simplified design approach was developed and applied for specifying geothermal heat pump size and heat exchanger loop length to meet all or part of building heat and cooling thermal loads. The developed guidelines would thus provide a proper design guide for installation of thermo-active foundations for heating and cooling of both US residential and commercial buildings.


2008 ◽  
Vol 2008.47 (0) ◽  
pp. 99-100
Author(s):  
Ko WATANABE ◽  
Takayoshi SUZUKI ◽  
Hiroyuki SEKI ◽  
Masafumi SASAKI ◽  
Noboru ENDOH ◽  
...  

2012 ◽  
Vol 512-515 ◽  
pp. 168-171
Author(s):  
Wei Yu ◽  
Feng Chen ◽  
Hong Bo Li

This article on a villas in Langfang city, Hebei province, heating and air conditioning systems. According to the owners of the double requirement of energy saving and environmental protection to owners selection of solar energy and geothermal heat pump heating system combined. To better achieve heating and air conditioning energy saving operation of villas, the system can be run by optimizing the control scheme, time-sharing partition building heat adjustment.


Author(s):  
Abdeen Omer

Globally buildings are responsible for approximately 40% of the total world annual energy consumption. Most of this energy is for the provision of lighting, heating, cooling and air conditioning. An increase in awareness of the environmental impact of CO2, NOx and CFCs emissions triggered a renewed interest in environmentally friendly cooling and heating technologies. Under the 1997 Montreal Protocol, governments agreed to phase out chemicals used as refrigerants that have the potential to destroy stratospheric ozone. An approach isneeded to integrate renewable energies in a way to achieve high building performance standards. However, because renewable energy sources are stochastic and geographically diffuse, their ability to match demand is determined by the adoption of one of the following two approaches: the utilisation of a capture area greater than that occupied by the community to be supplied, or the reduction of the community’s energy demands to a level commensurate with the locally available renewable resources. Ground source heat pump (GSHP) systems (also referred to as geothermal heat pump systems, earth-energy systems and GeoExchange systems) have received considerable attention in recent decades as an alternative energy source for residential and commercial space heating and cooling applications. The GSHP applications are one of three categories of geothermal energy resources as defined by ASHRAE and include high-temperature (>150°C) for electric power production, intermediate temperature (<150°C) for direct-use applications and GSHP applications (generally (<32°C). The GSHP applications are distinguished from the others by the fact that they operate at relatively low temperatures.


Sign in / Sign up

Export Citation Format

Share Document