Heat transfer correlation of the falling film evaporation on a single horizontal smooth tube

2016 ◽  
Vol 103 ◽  
pp. 177-186 ◽  
Author(s):  
Chuang-Yao Zhao ◽  
Wen-Tao Ji ◽  
Pu-Hang Jin ◽  
Wen-Quan Tao
Author(s):  
Lei Wang ◽  
Weiyu Tang ◽  
Limin Zhao ◽  
Wei Li

Abstract An experimental investigation was conducted on falling film evaporation along two porous tubes, which were sintered by stainless-steel powder with a diameter of 0.45 and 1 um, respectively. The test section is a 2 m long sintered tube with an outer diameter of 25 mm and a wall thickness of 2 mm. During the experiment, the pressure inside the tube was maintained at 1 atm, the inlet temperature was 373 K, and mass flux ranged from 0.51 to 1.36 kg/ (m s). Conditions of the steam outside the pipe, which was the heat source, were fixed, while the fouling tests were carried out at a constant mass flow of 0.74 kg/ (m s) using high-concentration brine as work fluid. The overall heat transfer coefficient under different working conditions was tested and compared with the stainless steel smooth tube of the same dimensions. The heat transfer coefficient of the two porous stainless tubes are about 35% and 20% lower than that of the smooth one, showing an inferior effect because the steam in the pores of the pipe wall during the infiltration process will reduce the heat conductivity. The heat transfer coefficient of the smooth tube deteriorated severely due to the deposition of calcium carbonate, which had little effect on the sintered tubes. Besides, the fouling weight of porous tubes is 2.01 g and 0 g compared with 5.52 g of the smooth tube.


2012 ◽  
Vol 28 (2) ◽  
pp. 319-327 ◽  
Author(s):  
L.-H. Chien ◽  
R.-H. Chen

AbstractThis study investigates evaporation heat transfer performance of refrigerant R-134a falling film on three horizontal copper tubes in a vertical column. Experiments were performed at saturation temperatures of 10 and 26.7°C. The liquid flows through a liquid feeder with a row of circular holes at a rate of 0.0075 ∼ 0.0363kg/ms, while heat fluxes varied from 4.5 to 48.5kW/m2. A smooth tube, a fin tube of 0.4mm fin height, 60FPI (Fins Per Inch), and a new boiling enhanced tube (mesh tube) were tested. The test results show that heat transfer coefficient of the smooth tube increases with increasing heat flux and fluid temperature, and increases slightly with increasing flow rate before dry-out occurs. At low flow rates (less than 0.015kg/ms) or when Ref (≤ 255), the fin tube is in thin film evaporation mode and results in a large heat transfer coefficient. At high flow rates (0.0225, 0.03, and 0.0375kg/ms) the falling film evaporation curves are similar to those in pool boiling. For all tubes, the fluid temperature and the flow rate have only minor influences on heat transfer coefficient before dry-out occurs. The 60 FPI tube and the mesh tube enhance the falling film evaporation heat transfer coefficient 6.3 ∼ 8.29 fold and 1.9 ∼ 5.0 fold, respectively, as compared with the smooth tube. A new correlation of falling film evaporation, accounting for contributions of nucleate boiling and spray convection, is proposed. It predicts h-values of the falling film evaporation data of the smooth surface within ±30%.


2012 ◽  
Vol 614-615 ◽  
pp. 296-300 ◽  
Author(s):  
Wei Kang Hu ◽  
Li Yang ◽  
Lei Hong Guo

This paper mainly studies the falling film evaporator in the field of water desalination. Using the method of fluent simulates the process of the liquid flowing and heat-transfer on the horizontal-tube falling film evaporation. The author analyses the distribution of the liquid film, and obtain the rule that spray density, evaporation temperature, temperature difference and pipe diameter affect the performance of heat-transfer in a certain range. So the paper plays a guiding role in heat transfer enhancement in the falling film evaporator.


Author(s):  
Wei Li ◽  
Xiaoyu Wu ◽  
Zhong Luo

This paper reports an experimental study on falling film evaporation of water on 6-row horizontal configured tube bundles in a vacuum. Three types of configured tubes, Turbo-CAB-19fpi and −26fpi, Korodense, including smooth tubes for reference, were tested in a range of film Reynolds number from about 10 to 110. Results show that as the falling film Reynolds number increases, falling film evaporation goes from tubes partial dryout regime to fully wet regime; the mean heat transfer coefficients reach peak values in the transition point. Turbo-CAB tubes have the best heat transfer enhancement of falling film evaporation in both regimes, but Korodense tubes’ overall performances are better when tubes are fully wet. The inlet temperature of heating water has hardly any effects on the heat transfer, but the evaporation pressure has controversial effects. A correlation with errors within 10% was also developed to predict the heat transfer enhancement capacity.


Sign in / Sign up

Export Citation Format

Share Document