Energy and exergy performance comparison of different configurations of an absorption-two-stage compression cascade refrigeration system with carbon dioxide refrigerant

2016 ◽  
Vol 104 ◽  
pp. 104-120 ◽  
Author(s):  
S.M. Hojjat Mohammadi ◽  
Mehran Ameri
Author(s):  
Hendri ◽  
Roswati Nurhasanah ◽  
Prayudi ◽  
Suhengki

Low temperature storage with a single refrigeration system only stable up to 228 K temperature. The purpose of this study is to develop a low temperature cool storage with cascade refrigeration system, with hydrocarbon refrigerants in terms of energy and exergy analysis. Experimental research in laboratories using refrigerant hydrocarbon MC22 and MC134 on the hight temperature circuit, and R404A and R502 using on low temperature circuit. Condenser heat exchanger using a type of exchanger plate. Resulting from this research, obtained that result the MC22/R404A, MC22/R502 and MC134/R404A refrigerant pair can reach a temperature of 220 K. The MC22/R404A refrigerant pair has god performance, COP, total loss exergy, and exergy efficiency is better than MC22/R502, and MC134/R04A refrigerant pairs.


Energy ◽  
2019 ◽  
Vol 170 ◽  
pp. 1170-1180 ◽  
Author(s):  
Zhili Sun ◽  
Qifan Wang ◽  
Zhiyuan Xie ◽  
Shengchun Liu ◽  
Dandan Su ◽  
...  

Author(s):  
Ahmet Selim Dalkilic¸ ◽  
Somchai Wongwises

Single-stage vapour compression refrigeration system was compared with an actual vapour compression cycle, single-stage process with internal heat exchanger, and a two-stage process with economiser using the refrigerants of HCFC-22, CFC-502 and their alternatives such as HFC-134a, HFC-32, HFC-152a, HFC-404A, HFC-407C, HFC-507, HFC-410A. A theoretical performance study on a cascade refrigeration system was performed using two refrigeration cycles connected through the heat exchanger in the middle working as the evaporator for the high pressurized cycle and condenser for the low pressurized cycle. Other performance study was performed using a two-stage cascade refrigeration system having low and high pressure compressors connected through the mixing chamber in the middle. The condensation temperatures were between 30 and 50 °C, evaporation temperatures were between −50 °C and 5 °C and heat exchanger and economiser temperatures were kept as constant for the comparisons. Some of the alternative refrigerants’ coefficients of performance values are found to be higher than their base traditional pure refrigerants. The effects of the main parameters of performance analysis such as refrigerant type, degree of subcooling, and superheating on the performance coefficient, refrigerant charge rate and volumetric refrigeration capacity are investigated for various operating conditions as case studies.


2021 ◽  
Vol 20 (2) ◽  
pp. 20
Author(s):  
V. B. Rangel ◽  
A. G. S. Almeida

Cascade refrigeration systems work with two or more serial disposed cycles and can obtain internal temperatures below -60°C, which is necessary for several activities in medicine and scientific research. This paper presents a thermodynamic analysis of cascade system refrigeration using natural refrigerant fluids for ultra-low temperatures. These fluids are environmentally friendly refrigerant and are an alternative to hydro chlorofluorocarbons (HCFCs) and to hydrofluorocarbons (HFCs). Energy and exergy analyses were performed using a thermodynamic model based on the law of conservation of mass and also on the first and second laws of thermodynamics. A simulator was developed to assess the technical practicability of this system, considering it running as a real refrigeration cycle. Natural fluids have best performance energetically and environmentally.


2013 ◽  
Vol 388 ◽  
pp. 96-100
Author(s):  
Nasruddin ◽  
M. Idrus Alhamid ◽  
Darwin R.B. Syaka ◽  
Arnas

Medicine and biomedical research activities require cold storage to store biomedical specimens such as, for example, stem cell, sperm, blood and other organs. During storage, to prevent the specimen from damage required a special cold storage reaches -80°C [1]. Using single cycle refrigeration machine can only reach -40°C, and performance deteriorates below -35°C drop in pressure associated with evaporation. Thus, to reach lower temperatures, use cascade refrigeration machine [2]. During this low-temperature circuit cascade refrigeration systems still use refrigerants that contain ozone-depleting or global warming (CFCs and HCFCs). To overcome this, a mixture of carbon dioxide and ethane azeotropic a promising alternative refrigerants. Simulation studies and experiments indicate a mixture of carbon dioxide and ethane were able to achieve the minimum temperature to -80°C [4-7]. With the mass ratio 70% R170 and 30% R744 circuit at low temperature refrigeration systems and uses a capillary tube expansion device 0.054 inch diameter with a length of 6 meters and 3 meters then use an electric heater as the cooling load. Cooling load is given by the variation of 90 W, 120 W and 150 W at a cabin in the low temperature circuit. From the experiment will be known characteristics of cascade refrigeration system with refrigerant mixture and will get the parameter data to make cascade refrigeration machine.