Experimental investigation on solid desiccant–vapor compression hybrid air-conditioning system in hot and humid weather

2016 ◽  
Vol 104 ◽  
pp. 556-564 ◽  
Author(s):  
D.B. Jani ◽  
Manish Mishra ◽  
P.K. Sahoo
Author(s):  
Yilin Du ◽  
Jan Muehlbauer ◽  
Jiazhen Ling ◽  
Vikrant Aute ◽  
Yunho Hwang ◽  
...  

A rechargeable personal air-conditioning (RPAC) device was developed to provide an improved thermal comfort level for individuals in inadequately cooled environments. This device is a battery powered air-conditioning system with the phase change material (PCM) for heat storage. The condenser heat is stored in the PCM during the cooling operation and is discharged while the battery is charged by using the vapor compression cycle as a thermosiphon loop. The conditioned air is discharged towards a single person through adjustable nozzle. The main focus of the current research was on the development of the cooling system. A 100 W cooling capacity prototype was designed, built, and tested. The cooling capacity of the vapor compression cycle measured was 165.6 W. The PCM was recharged in nearly 8 hours under thermosiphon mode. When this device is used in the controlled built environment, the thermostat setting can be increased so that building air conditioning energy can be saved by about 5–10%.


Energy ◽  
2016 ◽  
Vol 109 ◽  
pp. 180-189 ◽  
Author(s):  
Li Yinglin ◽  
Zhang Xiaosong ◽  
Tan Laizai ◽  
Zhang Zhongbin ◽  
Wu Wei ◽  
...  

2021 ◽  
Vol 250 ◽  
pp. 114926
Author(s):  
Erjian Chen ◽  
Jinfeng Chen ◽  
Teng Jia ◽  
Yao Zhao ◽  
Yanjun Dai

2008 ◽  
Vol 130 (11) ◽  
Author(s):  
Akihiko Horibe ◽  
Syahrul Husain ◽  
Hideo Inaba ◽  
Naoto Haruki ◽  
Ping Tu

An experimental investigation of a fluidized bed with multiple cooling pipes was conducted to study adsorption characteristics of a new organic sorbent desiccant material (HU300P) for a new air conditioning system. The mass ratio of the present sorbent desiccant powder type is from 1.3 to 2.3 times greater than that of silica gel. The sorption rate of the water vapor in the sorbent bed was measured under various conditions. It was found that the sorption rate is highly dependent on the effect of cooling pipes. The sorption ratio increases and the completion time for the sorption process decreases by using multiple cooling pipes.


2017 ◽  
Vol 123 ◽  
pp. 1134-1139 ◽  
Author(s):  
Dongliang Zhang ◽  
Ning Cai ◽  
Dongyan Gao ◽  
Xueying Xia ◽  
Xiaoqing Huang ◽  
...  

2019 ◽  
Vol 25 (7) ◽  
pp. 1-20
Author(s):  
Yasser Abdul Lateef Ghani ◽  
Abdul Hadi N. Khalifa

A time series analysis can help to observe the behavior of the system and specify the system faults. In addition, it also helps to explain the various energy flows in the system and further aid in reducing the thermodynamic losses. The intelligent supervisory LabVIEW software can monitor the incoming data from the system by using Arduino microcontroller and calculates the important parameters. Energy, exergy, and anergy analysis present in this paper to investigate the system performance as well as its components. To accomplish this, a 4-ton vertical split air conditioner based on vapor compression refrigeration cycle charged with refrigerant R-22 was modified for experimental analysis. The results showed that during 5400 secs of experimental study, the system shut down once by the software for 5 min. The volumetric and isentropic efficiencies of the compressor were 79.85 % and 64.48 % respectively. The maximum entropy generation was due to the compressor of 3.4 W/K while the maximum anergy was due to the condenser of 1.39 kW. The exergy efficiencies of the compressor, condenser, and the evaporator were 73.57, 40.18, and 47.45 % respectively. The system and Carnot COP were 2.53 and 4.9 respectively. The exergy efficiency of the air conditioning system was 48.7 %.  


Sign in / Sign up

Export Citation Format

Share Document