Experimental assessment of the retrofit of an internal heat exchanger in refrigeration systems: The effect on energy performance and system operation

2020 ◽  
Vol 180 ◽  
pp. 115843
Author(s):  
Vedat Oruç ◽  
Atilla G. Devecioğlu
2013 ◽  
Vol 21 (01) ◽  
pp. 1350005 ◽  
Author(s):  
Z. WANG ◽  
Y. GONG ◽  
X. H. WU ◽  
W. H. ZHANG ◽  
Y. L. LU

This work presents the experimental evaluation of the energy performance of transcritical CO2 refrigeration and heat pump systems. The optimal gas cooler pressures and the optimal COP have been analyzed from a thermodynamic point of view. The systems used a new dual expansion valve and a balance CO2 liquid receiver adjustment device, which can control high and low side pressure effectively. Moreover, we demonstrate the influence of the internal heat exchanger (IHX) on the systems' performances, on the basis of the analysis of the relative COP index RCOPI, the compressor power index RPCI and other parameters which can confirm the truth of. The experimental evaluation covers five evaporating levels (-10 to 10°C) and in a wide range of gas cooler pressures (75 to 120 bar). It is concluded that with the IHX system, compressor power is relatively low when the high side pressure is over 100 bar, and the evaporation temperature is below 0°C. The COP of the system without the IHX is slightly higher than the system with the IHX; it is increasing about 3% to 5%, when the evaporation temperature is over 5°C. Relative to the single expansion process, the dual expansion cycle can decrease the influence of pressure fluctuations of CO2 supercritical fluid and liquid mixture on the systems.


2012 ◽  
Vol 614-615 ◽  
pp. 259-264
Author(s):  
Wen Hui Zhang ◽  
Zhe Wang ◽  
Yi Gong ◽  
Xue Hong Wu ◽  
Yan Li Lu

This work present the experimental evaluation of the energy performance of trans-critical CO2refrigeration and heat pump systems. The optimal gas cooler pressure and the optimal COP have been analysed from a thermodynamic point of view. The experimental evaluation covers five evaporating levels (-10 to 10°C) and in a wide range of gas cooler outlet pressures (75 to 120bar). It is concluded that: With the the internal heat exchanger (IHX) system compressor power is relatively low, when the high side pressure is over 100bar, and the evaporation temperature is below 0°C. The COP of the system without IHX is slightly higher than the system with the IHX, it is increase about 3% to 5%, when the evaporation temperature is over 5°C.


Author(s):  
V. Pérez-García ◽  
D. Méndez-Méndez ◽  
J.M. Belman-Flores ◽  
J.L. Rodríguez-Muñoz ◽  
J.J. Montes-Rodríguez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document