scholarly journals Optimal placement and sizing of multi-type FACTS devices in power systems using metaheuristic optimisation techniques: An updated review

2020 ◽  
Vol 11 (3) ◽  
pp. 611-628 ◽  
Author(s):  
Ahmad AL Ahmad ◽  
Reza Sirjani
2019 ◽  
Vol 14 (1) ◽  
pp. 5-11
Author(s):  
S. Rajasekaran ◽  
S. Muralidharan

Background: Increasing power demand forces the power systems to operate at their maximum operating conditions. This leads the power system into voltage instability and causes voltage collapse. To avoid this problem, FACTS devices have been used in power systems to increase system stability with much reduced economical ratings. To achieve this, the FACTS devices must be placed in exact location. This paper presents Firefly Algorithm (FA) based optimization method to locate these devices of exact rating and least cost in the transmission system. Methods: Thyristor Controlled Series Capacitor (TCSC) and Static Var Compensator (SVC) are the FACTS devices used in the proposed methodology to enhance the voltage stability of power systems. Considering two objectives of enhancing the voltage stability of the transmission system and minimizing the cost of the FACTS devices, the optimal ratings and cost were identified for the devices under consideration using Firefly algorithm as an optimization tool. Also, a model study had been done with four different cases such as normal case, line outage case, generator outage case and overloading case (140%) for IEEE 14,30,57 and 118 bus systems. Results: The optimal locations to install SVC and TCSC in IEEE 14, 30, 57 and 118 bus systems were evaluated with minimal L-indices and cost using the proposed Firefly algorithm. From the results, it could be inferred that the cost of installing TCSC in IEEE bus system is slightly higher than SVC.For showing the superiority of Firefly algorithm, the results were compared with the already published research finding where this problem was solved using Genetic algorithm and Particle Swarm Optimization. It was revealed that the proposed firefly algorithm gives better optimum solution in minimizing the L-index values for IEEE 30 Bus system. Conclusion: The optimal placement, rating and cost of installation of TCSC and SVC in standard IEEE bus systems which enhanced the voltage stability were evaluated in this work. The need of the FACTS devices was also tested during the abnormal cases such as line outage case, generator outage case and overloading case (140%) with the proposed Firefly algorithm. Outputs reveal that the recognized placement of SVC and TCSC reduces the probability of voltage collapse and cost of the devices in the transmission lines. The capability of Firefly algorithm was also ensured by comparing its results with the results of other algorithms.


2020 ◽  
Vol 39 (3) ◽  
pp. 3839-3851
Author(s):  
Arun Nambi Pandian ◽  
Aravindhababu Palanivelu

Optimal placement of FACTS devices attempts to improve power transfer, minimize active power loss, enhance voltage profile and improve voltage stability, thereby making the operation of power systems more flexible and secured. The classical methods experience difficulties in solving the FACTS placement problem (FPP) with discontinuous functions and may diverge or result oscillatory convergence. Besides the number of FACTS devices for placement should be given as an input while solving the problem. The solution methods then attempts to forcefully place all the specified number of devices in the power system, but in reality, the system may require an optimal number of FACTS for placement. The application of swarm-intelligence based optimization algorithms strives to overcome the drawbacks of classical methods. This paper presents a new solution method for FACTS placement problem using improved harmony search optimization (IHSO) with a newly suggested dissonance mechanism that avoids badly composed music, with a view of avoiding the sub-optimal solutions. Besides, the method requires to specify only the maximum number of FACTS devices for placement and places only the optimal number of devices within the specified maximum number of devices. The paper also includes simulation results of three IEEE test systems for exhibiting the superiority of the proposed method.


Author(s):  
V. Tejaswini ◽  
D. Susitra

Power loss reduction, improvement of voltage profile, system reliability and system security are the important objectives that motivated researchers to use custom power devices/FACTS devices in power systems. The existing power quality problems such as power losses, voltage instability, voltage profile problem, load ability issues, energy losses, reliability problems etc. are caused due to continuous load growth and outage of components. The significant qualities of custom power devices /FACTS devices such as power loss reduction, improvement of voltage profile, system reliability and system security have motivated researchers in this area and to implement these devices in power system. The optimal placement and sizing of these devices are determined based on economical viability, required quality, reliability and availability. In published literatures, different algorithms are implemented for optimal placement of these devices based on different conditions. In this paper, the published literatures on this field are comprehensively reviewed and elaborate comparison of various algorithms is compared. The inference of this extensive comparative analysis is presented.  In this research, Meta heuristic methods and sensitive index methods are used for determining the optimal location and sizing of custom power devices/FACTS devices. The combination of these two methods are also implemented and presented.


2014 ◽  
Vol 984-985 ◽  
pp. 1286-1294
Author(s):  
R. Arun Prasath ◽  
M. Vimalraj ◽  
M. Riyas Ahamed ◽  
K. Srinivasa Rao

This paper presents a graphical user interface (GUI) uses Particle Swarm Optimization (PSO), which is used to find the optimal locations and sizing parameters of multi type Flexible AC transmission systems (FACTS) devices in complex power systems. The GUI toolbox, offers user to choose a power system network, PSO settings and the type and number of FACTS devices for the selected network. In this paper, three different FACTS devices are implemented: SVC, TCSC and TCPST. FACTS devices are used to increase the system loadability, by reducing power flow on overloaded lines, transmission line losses, improving system stability and security. With this can make the transmission system more energy-efficient. PSO used here for optimally allocating and sizing the multiple type FACTS in a standardized power network (IEEE 30 bus system) in order to improve voltage profile, minimizing power system total losses and maximizing system loadability with respect to the size of FACTS.


Author(s):  
Peerapol Jirapong

In this paper, a hybrid evolutionary algorithm (HEA) is proposed to determine the optimal placement of multi-type flexible AC transmission system (FACTS) devices to simultaneously maximize the total transfer capability (TTC) and minimize the system real power loss of power transfers in deregulated power systems. Multi-objective optimal power flow (OPF) with FACTS devices including TTC, power losses, and penalty functions is used to evaluate the feasible maximum TTC value and minimum power loss within real and reactive power generation limits, thermal limits, voltage limits, stability limits, and FACTS devices operation limits. Test results on the modified IEEE 30-bus system indicate that optimally placed OPF with FACTS by the HEA approach could enhance TTC far more than those from evolutionary programming (EP), tabu search (TS), hybrid tabu search and simulated annealing (TS/SA), and improved evolutionary programming (IEP) algorithms, leading to much efficient utilization of the existing transmission systems.


Author(s):  
Sekhane Hocine ◽  
Labed Djamel

The fast increase of loads around the world has made electrical networks more and more complex and difficult to operate close to its capacities. This is has led to many problems such as voltage collapse and energy losses. Therefore, flexible alternating current transmission systems (FACTS) are considred as a best solution for solving these problems. Unified Power Flow Controller UPFC is one of the most important and powerful FACTS devices due to its ability to increase the transmission capacity of the power system and reduce the total line losses. The problem of optimizing its number, location and size has become an important requirement for best advantages of this device. In this paper, a proposed relationship to identify the maximum number of FACTS devices that can be installed for a given power network is introduced in the search process code to determine the optimal number, optimal placement and size of UPFC device to enhance voltages profile and reduce overall system losses in the standard IEEE 14 bus test system using genetic algorithm (GA). The obtained results show clearly that all control parameters of UPFCs in each case are within their limits, and whenever the number of UPFCs installed increases, both voltage deviation and total losses well decreases. They also show that the application of the proposed relationship in the search process code facilitates greatly the search for optimal number, optimal placement and size of UPFC devices and reduces the calculation time. On the other hand, the obtained results has been scientifically justified and compared with other works reported in the literature.